<br />APPENDIX 13-0 <br /> <br />Climate Zones 4, 5, 6 <br /> <br />TABLE BC-1. PRESCRIPTIVE REQUIREMENTS FOR SMALL ADDITIONS (BOO Sq. FI. and Lesal, RENOVATIONS TO EXlSTNG BUILDINGS AND SITE"INSTALLED COMPONENTS OF MANUFACTURED HOMES <br /> <br /> EQUIPMENT MINIMUM INSTALLED <br /> EFFICIENCY EFFICIENCY <br /><!l Central AlC -Split SEER = 10.0 SEER = <br />z <br />:J - Single Pkg. SEER = 9.7 SEER = <br />0 <br />0 Room unit or PTAC EER = 8S EER = <br />'-' <br /><!l Electric Resistance ANY <br />Z Heat pump - Split HSPF = 6.8 HSPF = <br />~ - Single Pkg. HSPF = 6.6 HSPF - <br />:r: Room unit or PTHP COP =2.7" HSPFI' <br />UJ COP= <br />'-' AFUE = .78 <br />C1: Gas, natural or propane <br />CIJ Fuel 011 AFUE = .7B AFUE = <br /> AFUE _ <br />II: Electric Resistance EF = .92 EF= <br />t-UJ <br />O!;;: Gas; natural or LP-gas EF = .59 EF= <br />:r:~ Fuel Oil EF = .54 EF= <br /> <br /> MINIMUM INSULATION <br /> COMPONENT INSULATION INSTALLED <br /> Concrete Block R-5 K-l( <br />CIJ R.ll <br />..J Frame, 2' x 4' <br />..J Frame, 2' x 4' R-19 <br />~ Common, Frame R-ll <br /> Common. Masonry R-3 <br /> Under Attic R-30 <br />CIJ Single Assembly: Enclosed <br /><!l R-19 <br />z Frame ['-(3 <br />:J Metal Pans R-13 <br />ijj <br />'-' Single Assembly; Open R-l0 <br /> Common, Frame R-ll <br />CIJ Slab-on-grade No Minimum --er <br />II: R-ll <br />0 Raised Wood <br />0 Raised Concrete R-5 <br />..J <br />LL Common, Frame R-l1 <br />t- In unconditioned space R-6 .--- <br />'-' No minimum /' <br />:J In conditioned space <br />0 <br /> <br />TABLE BC.Z. PRESCRIPTIVE REQUIREMENTS FOR GLASS AREAS IN ADDITIONS ONlY <br /> <br />. See Table 13-607.1.ABC.3.2 and 13-60B.1.ABC.3.2 <br /> <br />Maximum percentage glass to floor area allowed Is selected by type, overhang length, and solar heat galn coefficient. Maximum % = lllnstalled % = ..75: <br /> GLASS TYPE, OVERHANG, AND SOLAR HEAT GAIN COEFFICIENT REQUIRED FOR GLASS PERCENTAGE ALLOWED <br />(UP TO 20% .J UP TO 30% UPTO 40% UP TO 50% <br />~ Double Single Double Single Double Single Double <br />'--oR-SHGC OH-SHGC OH-SHGC OH-SHGC OH-SHGC OH-SHGC OH-SHGC OH-SHGC <br />c::: 1'~ 0' - .7B 2' - .B7 I' - .7B 3' - .B7 2'. .7B 4' - .B7 3' - .78 <br />~0'-.75 1'- .75 0' - .61 2' - .75 1'. .61 3' - .75 2' - .61 <br /> 0' - .57 l' - .57 0' - .44 2' - .57 l' -.44 <br /> 0' - .39 l' - .39 0'. .35 <br /> 0' - .30 <br />Get certified SHGC from the manufacturer or use delaults: Single clear SHGC = .75, double clear SHGC = .66, and single tint SHGC = .64 <br />TABLE 6C-3 MINIMUM REQUIREMENTS FOR ALL PACKAGES <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Exterior Joints & Cracks 606.1 To be caulked, gasketed, weather.stripped or otherwise sealed. ,/ <br />Exterior Windows & Doors 606.1 Max. 0.3 cfm/sq.ft. window area; .5 clmlsq.ft. door area. V <br />Sole & Top Plstes 606.1 Sole plates and penetrations through top plates of exterior walls must be sealed. (/' <br />Recessed Lighting 606.1 Type IC rated with no penetrations (two altematives allowed). - <br />Multistory Houses 606.1 Air barrier on perimeter of floor cavity between floors. - <br />Exhaust Fens 606.1 Exhaust fans vented to unconditioned space shall have dampers, except for combustion devices with integral exhaust - <br /> ductwork. <br />Combustion Heating 606.1 Combustion space and water heating systems must be provided with outside combustion air, except tar direct vent - <br /> appliances. <br />Water Hesters 612.1 Comply with eN/ciency requirements in Table 612.1.ABC.3.2. Switch or clearty marked circuit breaker electric or cutoff - <br /> (gas) must be provided. External or built-in heal trap required for vertical pipe risers. <br />Swimming Pools & Spss 612.1 Spas & heated pools must have covers (except solar heated). Noncommercial pools must have a pump timer. Gas spa & - <br /> pool heaters must have minimum thermal effiCiency of 78%. <br />Hot Water Pipes 612.1 Insulation is required for hot water circulating systems (including heat recovery units). - <br />Shower Heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 pslg. - <br />HVAC Duct Construction, 610.' All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated and - <br />Insuletlon & Instsllation installed In accordance with the criteria of Section 610.1. Ducts In attics must be insulated to a minimum of A-S. <br />HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. - <br /> <br />GENERAL DIRECTIONS: <br />1. On Table 6C-llndlcate the R-value cf the insulation being added to each component and the efficiency levels of the equipment being installed. Ail R-values and efficiencies installed must meet or exceed <br />the minimum values listed. Components and equipment neither being added nor renovated may be left blank. <br />2. ADDITIONS ONLY. Determine the percentage of new glass to conditioned floor area in the add"lon as follows. Total the areas of all glass windows, sliding glass doors and giass door panels. Double the <br />area of all nonvertlcal roof glass and add It to the previous total. When glass in existing extertor walls Is being removed or enclosed by the addition, an amount equal to the total area of this glass may be <br />subtracted from the total glass area. Divide the adjusted glass area total by the conditioned Noor area of the addition. Multiply by 100 to get the percent. And the largest glass percentage under which your <br />calculated percentage fails on Table 6C-Z. Prescrtptlves are given by the Iype of glass (single or double pane) and the overhang (OH) paired w"h a solar heat gain coefficient (SHGC). For a given glass type <br />and overhang, the minimum solar heat gain ccefflcient allowed is specified. Actual glass windows and doors previously in the exterior wails of the house nd being reinstalled In the addition do not have 10 <br />comply with the overhang and solar heat gain coefficient requirements on Tabfe 6C-Z. All new glass in the addition must meet the requirement for one of the options in the glass percentage category you <br />indicated. The overhang (OH) distance is measured perpendicularly from the face of the glass to a point directly under the outermost edge of the overhang. <br />3. RENOVATIONS ONLY. Repiacement glass needs to meet the following requirements. Any glass type and solar heat gain coefficient may be used for glass areas which are under at least a 2-Ioot overhang <br />and whose lowest edge does not extend further than 8 feet from the overhang. Glass areas being renovated that do not meet this criteria must be either single-pane tinted, double-pane clear or double-pane <br />tinted. <br />4. BUILDING SYSTEMS. Comply when new system is installed for system installed. <br />5. Complete the information requested on the top half of page 1. <br />6 Read 'Mlnlmum Requirements for Small Additions and Renovations: Table 6C-3. and check ail applicable Items. <br />7. Read. sign and date the 'Owner/Agenf certification statement on page 1. <br /> <br />13-0.36 <br /> <br />FLORIDA BUILDING CODe - BUILDING <br />