<br />FORM 600A-2004 <br /> <br />EnergyGauge@ 4.0 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />Multi-story Hduses <br />Additional Infiltration reqts <br /> <br />I ADDR9SS: ,ZEPHYRHILLS, , <br /> <br />6A-21 INRIL TRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COM PONE' TS SECTION REQUIREMENTS FOR EACH PRACTICE <br />Exterior Win pows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. <br />Exterior & A jacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br />foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br />penetrations; between wall panels & top/bottom plates; between walls and floor. <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />from, and is sealed to, the foundation to the top plate. <br />606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br />EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />to the perimeter, penetrations and seams, <br />606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />installed that is sealed at the perimeter, at penetrations and seams. <br />Recessed Liqhting Fixtures 606.1.ABC.1,2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br />sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />conditioned space, tested. <br />606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. <br />606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br />have combustion air. <br /> <br />PERMIT #: <br /> <br />CHECK <br /> <br />Floors <br /> <br />Ceilings <br /> <br />COMPONEN S <br />Water Heater <br /> <br />6A-22 on ER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> <br />SECTION <br />612.1 <br /> <br />REQUIREMENTS CHECK <br />Comply with efficiency requirements in Table 612.1.ABC.3.2, Switch or clearly marked cir <br />breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required. <br />Spas & heated pools must have covers (except solar heated). Non-commercial pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />efficiency of 78%. <br />Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. <br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br />Ducts in unconditioned attics: R-6 min. insulation. <br />Separate readily accessible manual or automatic thermostat for each system. <br />Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br />Common ceiling & floors R-11, <br /> <br />Swimming PO~IS & Spas <br /> <br />612.1 <br /> <br />Showerhead~ <br />Air Distributi01 Systems <br /> <br />612.1 <br />610.1 <br /> <br />HVAC Control~ <br />Insulation <br /> <br />607.1 <br />604.1, 602.1 <br /> <br />I <br /> <br />EnergyGauge , DCA Form 600A-2004 <br /> <br />EnergyGauge@/FlaRES'2004 FLRCSB v4.0 <br />