Laserfiche WebLink
<br />Page 1 <br /> <br />Report Prepared By: <br /> <br />Fo~: <br /> <br />Residential Heat Loss and Heat Gain Calculation <br />-- ---"-~~-~"----'--'--"-'-"._----~ _..___._._.___._._m__._____._________..___.___...._______ ____ <br />In accordance with ACCA Manual J <br /> <br />Chris' AlC Company <br /> <br />DUPLEX / MARSELLA CONSTRUCTION <br /> <br />, DADE CITY <br /> <br />[h!1i-gnUconCiitions; _n -Ocala---- <br /> <br />Indoor: <br />Summer temperature: 75 <br />Winter temperature: 72 <br />Relative humidity: 50 <br /> <br />- --- J---'- -- - '_n,__ -------,----- ---- <br />Bui~ding Component <br /> <br />4 <br />1,230 sq.ft. <br />355.7 sq.ft. <br />10 sq.ft. <br />10 sq.ft. <br />3 sq.ft. <br />175.5 sq.ft. <br />1 0 sq. ft. <br />22.5 sq.ft. <br />350.2 sq.ft. <br />10 sq.ft. <br />10 sq.ft. <br />6 sq.ft. <br />3 sq.ft. <br />208 sq.ft. <br />1,230 sq.ft. <br /> <br />Sensible <br />Gain <br />(BTUH) <br /> <br />- . - --.'----------..--- <br />8,915 <br />8,923 <br />8,923 <br />657 <br />1,200 <br />o <br />732 <br />294 <br />294 <br />88 <br />361 <br />874 <br />224 <br />721 <br />464 <br />464 <br />278 <br />139 <br />428 <br />1,705 <br /> <br />\f!~.-t-'~B~-~-~!-=~=~--- ..~-~!!~~_~~f!:_____.__ <br />Firs Floor <br />A I Rooms 1,230 sq.ft. <br />! Infiltration <br />i People <br />Floor <br />NWall <br />Window <br />Window (2) <br />Window (3) <br />EWall <br />Window <br />Door <br />SWall <br />Window <br />Window (2) <br />Window (3) <br />Window (4) <br />Iwwall <br />Ceiling <br /> <br />Who e House <br /> <br />1,230 sq.ft. <br /> <br />8,915 <br /> <br />Outdoor: <br />Summer temperature: 93 <br />Winter temperature: 34 <br />Summer grains of moisture: 116 <br />Daily temperature range:Medium <br /> <br />Latent <br />Gain <br />(BTUH) <br /> <br />2,080 <br />-- . - . ---------~_._------ <br />2,094 <br />2,094 <br />1,174 <br />920 <br />o <br />o <br />o <br />o <br />o <br />o <br />o <br />o <br />o <br />o <br />o <br />o <br />o <br />o <br />o <br /> <br />2,080 <br /> <br />Total <br />Heat Gain <br />(BTUH) <br /> <br />10,995 <br />- -.....------.------...--------.- <br />11,017 <br />11,017 <br />1,831 <br />2,120 <br />o <br />732 <br />294 <br />294 <br />88 <br />361 <br />874 <br />224 <br />721 <br />464 <br />464 <br />278 <br />139 <br />428 <br />1,705 <br /> <br />10,995 <br /> <br />HVA -Calc Residential 4.0 by HVAC Computer Systems Ltd. <br />Load calculations are estimates only, actual loads may vary due to weather and construction differences, <br /> <br />10/11/2006 <br /> <br />Total <br />Heat Loss <br />(BTUH) <br /> <br />__ _U_'_'__'_'_ <br />17,844 <br />17,876 <br />17,876 <br />2,740 <br />o <br />4,519 <br />1,946 <br />439 <br />439 <br />132 <br />960 <br />439 <br />393 <br />1,916 <br />439 <br />439 <br />263 <br />132 <br />1,138 <br />1,542 <br /> <br />17,844 <br /> <br />------,-. ..--- - --_. -..----.-,---- ---..-----------.----..--------.-----__...___.____ _'0"." _ __...._.__....._..__.._~.___ <br /> <br />888736-1101 <br />