My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
07-6122
Zephyrhills
>
Building Department
>
Permits
>
2007
>
07-6122
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:37:11 PM
Creation date
10/26/2007 9:37:27 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-6122
Building Department - Name
RYMAN CONST.
Address
36413 SR 54
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />FORM 600A-2004 <br /> <br />EnergyGauge@ 4.0 <br /> <br />Code Compliance Checkl~st <br />Residential Whole Building Performance Method A - Details <br /> <br />I ADDRfSS: PASCO CO., Z-HILLS, FL, <br /> <br />PERMIT #: <br /> <br />6A-21 INFIL TRA TION REDUCTION COMPLIANCE CHECKLIST <br />COM PONE NTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Wi Ildows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfmIsq.ft. door area. <br />Exterior & I djacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealed to, the foundation to the top plate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the perimeter, penetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the perimeter, at penetrations and seams. <br />Recessed qghting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned space. tested. <br />Multi-story ~uses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. <br />Additional In Itration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br />6A-22 OT -fER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONE~ TS SECTION REQUIREMENTS CHECK <br />Water Heate ;s 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir <br /> , breaker (electric) or cutoff (gas) must be provided. Extemal or built-in heat trap required. <br />Swimming P~ols & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiency of 78%. <br />showerhea~ 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. <br />Air Distributi Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br />HVAC controls Ducts in unconditioned attics: R-6 min. insulation. <br />607.1 Separate readily accessible manual or automatic thermostat for each system. <br /> I <br />Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> j Common ceiling & floors R-11. <br /> <br />EnergyGauge ~ DCA Form 600A-2004 <br /> <br />EnergyGaugeGlllFlaRES'2004 FLRCSB v4.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.