Laserfiche WebLink
<br />FORM .600A-2004 <br /> <br />EnergyGauge@ 4.0 <br /> <br />Code Compliance Checkl~st <br />Residential Whole Building Performance Method A - Details <br /> <br />l ADDRFSS: PASCO co., Z-HILLS, FL, <br />6A-21 IN FILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONE NTS <br />Exterior Wi ndows & Doors <br />Exterior & ,t.djacent Walls <br /> <br />SECTION <br />606.1.ABC.1.1 <br />606. 1.ABc.1.2. 1 <br /> <br />Floors <br /> <br />606.1.ABC.1.2.2 <br /> <br />Ceilings <br /> <br />606.1.ABC.1.2.3 <br /> <br />Recessed ~ighting Fixtures <br /> <br />606.1.ABC.1.2.4 <br /> <br />Multi-story tltouses <br />Additionall~filtratjon reqts <br /> <br />606.1.ABC.1.2.5 <br />606.1.ABC.1.3 <br /> <br />REQUIREMENTS FOR EACH PRACTICE CHECK <br />Maximum:.3 cfm/sq.ft. window area; .5 cfmIsq.ft. door area. <br />Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br />foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br />penetrations; between wall panels & toplbottom plates; between walls and floor. <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />from, and is sealed to, the foundation to the top plate. <br />Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br />EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />to the perimeter, penetrations and seams. <br />Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />soffits, chimneys. cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />installed that is sealed at the perimeter, at penetrations and seams. <br />Type IC rated with no penetrations, sealed; or Type IC or non-IC rated. installed inside a <br />sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />conditioned space, tested. <br />Air barrier on perimeter of floor cavity between floors. <br />Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br />have combustion air. <br /> <br />COMPONE~TS <br />Water Heat+rs <br /> <br />SECTION <br />612.1 <br /> <br />6A-22 OltHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> <br />Swimming I=/ools & Spas <br /> <br />612.1 <br /> <br />Showerhea~s <br />Air Distributi~m Systems <br /> <br />612.1 <br />610.1 <br /> <br />HVAC Contrpls <br />Insulation <br /> <br />607.1 <br />604.1, 602.1 <br /> <br />REQUIREMENTS CHECK <br />Comply with efficiency reqUirements in Table 612.1.ABC.3.2. Switch or cJearty marked cir <br />breaker (electric) or cutoff (gas) must be provided. Extemal or built-in heat trap required. <br />Spas & heated pools must have covers (except solar heated). Non-commercial pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />efficiency of 78%. <br />Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. <br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br />Ducts in unconditioned attics: R-6 min. insulation. <br />Separate readily accessible manual or automatic thermostat for each system. <br />Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br />Common ceiling & floors R-11. <br /> <br />EnergYGaug.1M DCA Form 600A-2004 <br /> <br />EnergyGauge@lFlaRES'2004 FLRCSB v4.0 <br />