<br />I <br />FORM 600A-2004 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />EnergyGauge@ 4.0 <br /> <br /> <br />PERMIT #: <br /> <br />6A-21 INFIL TRA TION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPON ::NTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior W ndows & Doors 606.1.ABC. 1. 1 Maximum:.3 cfmJsq.ft. window area; .5 cfmJsq.ft. door area. <br />Exterior & /\djacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windOWS/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; jOints between exterior wall panels at comers; utility <br /> penetrations; between wall panels & topJbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealed to, the foundation to the top plate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the perimeter, penetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the perimeter, at penetrations and seams. <br />Recessed L/ghting Fixtures 606. 1.ABC. 1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned space, tested. <br />Multi-story ~ouses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. <br />Additiona/lrfiltration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br />6A-22 OT HER PRESCRIPTIVE MEASURES (must be met or exceeded by aU residences.) <br />COMPONEI TS SECTION REQUIREMENTS CHECK <br />Water Heate rs 612.1 Comply with efficiency reqUirements in Table 612.1.ABC.3.2. Switch or clearly marked cir <br /> I breaker (electric) or cutoff (gas) must be Provided. Extemal or built-in heat trap required. <br />Swimming P~ols & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thennal <br /> efficiency of 78%. <br />showerheadt 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. <br />Air Distributlo Systems 610.1 All ducts, fittings. mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in aCCOrdance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />HVAC Contro~ 607.1 Separate readily accessible manual or automatic thennostat for each system. <br />Insulation 604.1, 602.1 Ceilings-Mln. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />EnergyGauge TMI DCA Fonn 600A-2Q04 <br /> <br />EnergyGaugeGM=JaRES'2004 FLRCSB v4.0 <br />