Permit #
07-6220
Building Department - Name
BISSON,RAYMOND
Address
39027 6TH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />APPENDIX 13-D <br /> <br />ADDITIONAL TABLES <br />6A-19 COOLING CREDIT MULTIPLIERS <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A-20 AIR DISTRIBUTION SYSTEM CREDIT MULTIPLIERS <br /> <br />SYSTEM TYPE Cooling credit multipliers (CCM) <br />Ceiling Fans .95. <br />Cross Ventilation .95" <br />Whole House Fan .95' <br />Muttizone .95 <br />Programmable Thermostat .95 <br /> <br />TYPE CREDIT prescriptive requirements Multiplier <br />Air-tight Duct Credit' 610.1.A.l 1.00 <br />Factory-sealed AHU Credit' 610.2.A.2.1 0.95 <br /> <br />'Duel Sealing Mulliplier(DSM) shall be 1.15 (summer) Dr 1.16 (winter) unless Air-tight Duct Gredit <br />is demonstraled by tesl report. <br />'Multiply Factory-sealed AHU Gredil by summer (Table 6A-7) Dr winter (Table 6A-16) AHU <br />mulliplier. Insert total in the ':As Built AHU. box on page 2 Dr 4. <br /> <br />"Credit may be taken for only one system type concurrenliy. <br />6A-21 HEATING CREDIT MULTIPLIERS (HCM) <br /> <br />SYSTEM TYPE HEATING CREDIT MULTIPLIERS IHCM\ <br />Programmable Thermostat HCM .95 <br />Multizone HCM .95 <br /> AFUE .68-.72 .73-.77 78-.82 .83- .87 .88-.92 .93 & Up <br />Natural Gas <br /> HCM .51 .56 .53 .50 .47 .44 <br />LP-Gas HCM .77 .72 .67 .63 .50 .57 <br /> <br />6A-22 HOT WATER MULTIPLIERS (HWM) <br /> <br />SYSTEM TYPE See Tabla 1J-6121.ABC.3.21or code mlJlimums HOT WATER MULTIPLIERS (HWM) <br /> EF .80-.81 .82-.83 .84-.85 .86-.87 .88-.90 .91-.93 .94-.96 .97 &Up <br />Electric Resistance <br /> HWM 2820 2752 2685 2624 2564 2479 2400 2326 <br /> EF .43-.47 .48-.49 .50-.51 .52-.53 .54-.55 .56-.57 .58-.59 .60-.61 .82-.63 .64-.65 .66 &Up <br />Natural Gas <br /> HWM 2162 1936 1859 1787 1721 1660 1602 1549 1499 1452 1408 <br />LP-Gas HWM 2645 2368 2274 2186 2106 2031 1960 1895 1834 1776 1722 <br /> EF 1.0-1.49 1.5-1.99 2.0-2.49 2.5-2.99 3.0-3.49 3.5-3.99 4.0-4.49 4.5-4.99 5.0-Up <br />Ded. HP or Soiar System with Tank <br /> HWM 2256 1504 1128 902 752 645 564 501 451 <br /> <br />6A-23 HOT WATER CREDIT MULTIPLIERS (HWCM) <br /> <br />SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS (HWCM) <br /> With Air Conditioner Heat Pump <br />Heat Recovery Unit <br /> HWCM .84 .78 <br />Add-on Dedicated Heat Pump (without EF 2.0-2.49 2.5-2.99 3.0-3.49 I 3.5 & Up <br />tank) HWCM .44 .35 .29 I .25 <br /> EF 1.0-1.9 2.0-2.9 3.0-3.9 1 4.0-4.9 I 5.0 & Up <br />Add-on Soiar Water Heater (without tank) I 1 <br /> HWCM .84 .42 .28 .21 .17 <br /> <br />NOTE: An HWM must be used in conjunction with all HWGM. See Table 6A-22. EF Means Energy Factor. <br /> <br />6A-24 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 806.1.ABC.l.l Max: 3 etm/sq. ft. window area; .5cfm/sq. ft. door area. <br /> Caulk. gasket, weatherstrip or seal between: windows/doors & frames. surrounding wall: foundation & wall sole or sill plate; joints <br />Exterior & Adjacent Walls 606.1.ABC.l.2.1 between exterior wall panels at comers; utility penetrations; between wall panels & toplbottom plates; between walls & floor. <br />EXCEPTION: Frame walls where a continous infiltration barrier is installed that extends from. and Is sealed to, the foundation to <br /> the ton nlate. <br />I Floors 608.1.ABC.1.2.2 Penetrations/openings> 1/8/1 sealed unless backed by truss or joint members. EXCEPTION: Frame floors where a continuous <br />infiltration barrier is installed that is sealed to the oanmerer, oenetrations and seams. <br />Ceilings Seal: Between walls & ceilings: penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys. cabinets sealed <br />606.1.ABC.1.2.3 to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous in'iUration <br /> barrier is installed that is sealed at the perimeter, at nenetratlons and seams. <br />Recessed Lighting Fixtures 606.1.ABC.l.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a sealed box with 1/2" clearance & 3" from <br />insulation; or Tvne IC rated with <2.0 elm from conditioned snacs, tested. <br />Multistory Houses 506.1.ABC.l.2.5 Air barrier on perimeter of floor cavity between floors. <br />Additional Infiltration reqts 606.1.ABC.l.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. <br /> <br />6A-2S OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by aU realdence..) <br /> <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be <br />rovided. External or built-in heat tran reouired for vertical nine risers. <br />Swimming Pools & Spas 812.1 Spas & heated pools must have covers (except solar heated). Nan..commercial pools must have a pump timer. Gas spa & pool heaters <br />must have a minimum thelTTlal efficiencY' of 78%. <br />Shower Heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings. mechanical equipment and plenum chambers shall be mechanically attached. sealed, Insulated. and installed in <br />accordance with the criteria of Section 610. Ducts in unconditioned attics: A-6 minimum Insulation. <br />HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. <br />Insulation 604.1,602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. <br /> <br />13-D.20 <br /> <br />Page 6 <br />FLORIDA BUILDING CODE - BUILDING <br />