Laserfiche WebLink
<br />FORM 600A-2004R <br /> <br />EnergyGauge@ 4.5 <br /> <br />Code Compliance Checklist <br />R~sidential Whole Building Performance Method A - Details <br /> <br />I ADDRES~: ST.AUGUSTINE W/OFFICE, 2937', , <br /> <br />6A-21 INFIL TRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />SECTION REQUIREMENTS FOR EACH PRACTICE <br />i 606.1.ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfm/sQ.ft. door area. <br />606.1.ABC.1.2.1 ,Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br />I foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br />I penetrations; between wall panels & top/bottom plates; between walls and floor. <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />from, and is sealed to, the foundation to the top plate. <br />Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br />I EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />i to the perimeter, penetrations and seams. . <br />606.1.ABC.1.2.3 I Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />I soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />I attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is I <br />I . .. .... i installed that is sealed at the perimeter, at penetrations and seams. <br />Recessed Lighfing Fixtures i 606.1~ABC.1 :2.4~r Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br />, sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />. "_ql_ _.. i I conditioned space, tested. <br />Multi-story Ho ses ~6.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. <br />Additionallnfilt ation reqts I 606.1.ABC.1.3 i Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, I <br />, i I have combustion air. i <br /> <br />COMPON~tiI__ <br />,E:)(~l()r_ Win.QQ N.,s &_Doors <br />Exterior & Adja ent Walls <br /> <br />PERMIT #: <br /> <br />I <br /> <br />CHECK <br /> <br />i I <br />--------_._---j--~--- <br />Floors i 606.1.ABC.1.2.2 <br />I <br /> <br />Ceilings <br /> <br />--- j--~- - <br /> <br />6A-22 OTH R PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> <br />COMPONENTS <br /> <br />Water Heaters <br />I <br /> <br />Swimming p091s & Spas <br /> <br /> <br />Shower hea~s <br />------ ---------_.- <br />Air Distribution Systems <br /> <br />I <br />~y A.Q co~~~t <br /> <br />Insulation <br /> <br />I REQUIREMENTS <br />; Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir <br />b!eak~ielectric) or cutoff (gas) must be provided. External or built-in heat trap required. <br />Spas & heated pools must have covers (except solar heated). Non-commercial pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />efficiency of 78%. <br />1 612.1-------- Water flow must be restricted to no more than 2.5 qallons per minute at 80 PSIG. <br />I. 610.1 I All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />'I' attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br />I . Ducts in unconditioned attics: R-6 min. insulation. <br />I <br />I 607.1 ----1 Separate readily accessible manual or automatic thermostat for each svstem. <br />I 604.1, 602.1 I Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br />; I Common ceiling & floors R-11. <br />I <br /> <br />, SECTION <br />, 612.1 <br /> <br />CHECK <br /> <br />612.1 <br /> <br />EnergYGauge~M DCA Form 600A-2004R <br /> <br />EnergyGauge@/FlaRES'2004 FLRCSB v4.5 <br />