Laserfiche WebLink
<br />I <br />02-05-' 7 13:12 FROM-ABC SUPPLY CO, <br /> <br />5V..CRIMJP' PANEL <br /> <br />INST LLATION SPECIFICATIONS <br />ROOF lCATtON: Roorsll~pe must be a minimum of <br />3/11 P'tch en~u('e ptoper drain~ge. <br /> <br /> <br />, eDUalIlJ.lPJi~til)nti. Gj'bndrar CoastnlcdOb,PnM1aClS <br />the 'llse or p~ or OSE dedi;;, In "dditioft 'we SfJedFy s , <br />31Jif rrlt 1ici i R@CI in lI=m1;mce wlfl1 J'DUr' lnal' hbMing ~de 10 CODtr.oI <br />.:~llGo. ,It un baht; a~ llsed 10 senJn! the 30tI Celt Provide'~ poUnd <br />felt o~ top 0 the JO pound ~lt in the !ame dired.ton DS,ltlf,l panda t'ol" a, ' <br />liepa't3tiGr!,!1 ~ (lbttenstrtps 1m Ui"I~b!rs ~ to II p~ IIeck <br />i.r1! itpiUlilal.' 'It' tlm ~~ paramda-s dilrer rrom thO!e stated in ftte . <br />l'Mtming !!I~ dole., Qn ~ges 8 & 9, 'SP,ll('i6c! f:llrtming ~lctt'''doIIS mMt be <br />cOO,puttl", llD ~eer. , " , , ' , <br />.... '... i '.' <br />Wo~ Dee : :Must be minimum :LI2" liItructun,l plywood or OSB <br />(5/8" fI Metro-Dade n.ew eofISt1'Ucti,on) "upponed 0:0 rafters ilt <br />a m,ax mum of 24" on-cenler. B.tten.: S:\'-Crimp metal <br />t'ootin caft be separated :rrorn the moittun bal"rl.er by <br />minim nt, nOMinal r! ~ 3" yellow pin~ battetl$ t1p1.ced on <br />maxim m lIS" center!! or aCOOl'ding to A5CE ealcu latioZ2S where <br />applic Ie. CAtn;'ION: Dil:-Ect contact between presllUft <br />ttu lurnbeJ' and metal rooftn,,; must be a..,lded in Ol:'def <br />t(I at potential CC'lrrwiClI." The battens m~t be ftlsl'Ct1Cd <br />to the of deck with mtnimurn I/ll6 screWl'i at 1,2" olJ-c:entet or <br />two ., um 8d common 01: pneumatic Tlail.s spaced 8" On. <br />c:;eQ~ r OIIe evety 4" OI1-CCl3ttr (or by a1?P.lic:able c;a1culations <br />accord 8 to ASCE 7-98 or lS'91 NOS Standards.) Battel'ls <br />must in~taned to suppon thl~ ~ntlt'e wichh and length of Mdge, <br />eave., h p. valley. and gable end trims. Battens are optional if <br />r~.r.oo III over shiogJes. NOT!: le.t'C)Ofing over shinSlcs <br />without a batten ls allowed prc1vic1ing toe foof has been checked <br />by a lie tl5ed roo1iAl coatraetcrr to in5ut'$lcvelness and pull.out <br />iottgri . <br />1. Start at the Rable or rake oppl)~.ite of the prc'vailing -lnd on a , <br />gable f. or Start at the end or. center of a hip roof. for ut1lform <br />appean. ,te. The leadmg edgl;~ !:hould be the pal~ of inverted <br />' V'8 "Ii the anti.~iph01l thanMt. ' <br />2, It is Un ative tbat the pane!.'! bl~ laid in square to inl'lure Pt9l?eK I <br />lapping (many Installers pop a chalk line 26" fi:'om the gable <br />edge TU ning from the ridle t,) the eave to use as a guide.) <br />CAUl'J N: Do not apply c:hlitJk to panels <br />3, SIDE AP PROCEDURE: Pleue /lee the siele lap detail. <br />Paye 1 attention that tho a..."'i-lIiipho,, cbOUll1el is ovCl'lapped <br />by the ouble inver.ted Vtg all $hown In the side lap d~tail. <br /> <br />4 <br /> <br /> <br />~AR CONSTRUCTION PRODUCTS <br /> <br />3525232227 <br /> <br />T-520 P005/016 F-138 <br /> <br />4, END LAP PROCEDURE: When 28' (Feet) Of longer pane <br />are required, Gibraltar Construction P,l'Qduct$ recOT?:\rneods t1- <br />eultom~t' Itl'ld lap the panch a minimum of 12 <br />to insm:e proper dUllnage. Two strips Of butyl sealant tape shoul <br />be used at the end lap. Fastetlen; should be on the uphill ~ide: ( <br />the strips of "utyl sealant tape. <br />5. EAVE DETAIL PROCEDURE: Gibcaltar Construction Prod, <br />ucts recommends the uSE: of an -eaVE: flashing with a pre-glue <br />Cl03ure 3mI' (i.nside) wldch will go between the un~tdc I <br />the roofiDg panel and the top side of [he flashing to avo~d watl <br />infiltrstion, fastened on 6" centers. <br />6. :RIDGE DEl'.<\.U.. PROCEDURE: The appropriate ridge cap <br />placed on top of the pre-glued closure strips (outside) and fa; <br />tened on 6;1 centers. <br />7. FASTENERSt Conlult Gibl;'altar Cone.truction Products On sp. <br />cific l;&commel;1,dltiotls ~prdins compatIble fasteners. Fai <br />tene:r selection Is based on me subIa-are of me specific materi; <br />cbosen for applicatioa and the C13vironrneot in which you at <br />loeated. (Ree &$ten;,,! schedule p, 8-9) <br />Metal-to.Wood Applicath",: 'V-Crimp p~els should be fastenc: <br />"by I min\lnwn of #9 x 1-112" compatible fastener. <br />MetaJ-to-Metal Application: 5V-Qjmp panels should be i.stene <br />with a minim.um *12 :It I" b~ bead Tek Sc.cew. <br />8, FLASJ:D:NG5: 'Eave, sable. vaJJay. bip and rldae flasbing mu~ <br />"be Oibralw CoosavclioQ Producu' material. <br />,. CAULKING: Must be approved by the tt1l1ll1.faC:blter.. but: <br />sealant supplied in t3pe or gun-gnde form. <br />10. PIPE BOOTS: CAUTION Mun not be lead-type boots. (p.l' <br />TRIMMING AND CUTl'ING STF..EL PANELS: <br />Whetoer cutting with the profile (lCl1gm wise) Or acrol5 the profi: <br />(width wise), it is best EO use an eleetric nibbler. $he$.~ or hand iii <br />snips. It is vety impcttant to cut pallets one at a. t:bJle with the tini~ <br />&ide of thc pancl faciog down on wood blocks, Care sbould. be take <br />to tnlun: that ttle bot metal panicles and filings from cutting an <br />lC('e'M,ilJl to do not become embedded in the patlet. <br />r-:om: ..Ni~len' ~8~Ki)6\fOuilct,lt:,~Ost:'~ ,t601 diStrio.u.tOr~., ," <br />CA~TION~ ,lflmg;:(fiim, s"'t,~ ~ftd ,tJitnef::c:1dth1~;m:uSt ';b <br />cl~~ ~,:tM:~8,:~ ~Ilaw:, ~ ,a,~pii~"t,i~ug <br />the, pan'~'.w.'I~ld 'rUst 'ibtks or, ''b~ine''',on th~ pa~ds. . Fai <br />~:to cOIoply wittr,tbe'abO\l'e,p~u", rdic'ves Gibraltar CoJ <br />'tn~OIl:P1'odUets Of'NIp)nabOlty -,or "DY l'eftlJting' dam.~ <br />' to) O~ detenon.ti~n ttf'the fluuh end' voids any P3mt Of' finis <br />wtlrramy; , ' , <br /> <br />(800) 690-7235 <br /> <br />oS <br />