Laserfiche WebLink
<br />Manual J Summer Calculations <br />Residential Load - Component Details (continued) <br />RYMAN HO ES Project Title: Code Only <br />MODEL 1415 Professional Version <br />Climate: Central <br /> <br /> <br />2/5/2007 <br /> <br />I WHOLE H USE TOTALS <br /> <br /> Sensible Envelope Load All Zones 12658 Btuh <br /> Sensible Duct Load 2534 Btuh <br /> Total Sensible Zone Loads 15192 Btuh <br /> Sensible ventilation 1759 Btuh <br /> Blower 0 Btuh <br />W ole House Total sensible gain 16951 Btuh <br />Total for Cooling Latent infiltration gain (for 56 gr. humidity difference) 1252 Btuh <br /> Latent ventilation gain 3806 Btuh <br /> Latent duct gain 615 Btuh <br /> Latent occupant gain (5 people @ 200 Btuh per person) 1000 Btuh <br /> Latent other gain 300 Btuh <br /> Latent total gain 6973 Btuh <br /> TOTAL GAIN 23923 Btuh <br /> <br /> <br />GOODMAN #GSH3024(Outside)GOODMAN #ARUF1824(1 sidBfPOO Btuh <br /> <br /> <br />pes (Pn - Number of panes of glass) <br />(SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) <br />(U - Window U-Factor or 'DEF' for default) <br />(InSh -Interior shading device: none(N), Blinds(B), Draperies(D) or Roller Shades(R)) <br />(ExSh - Exterior shading device: none(N) or numerical value) <br />(BS - Insect screen: none(N), Full(F) or Half(H)) <br />(Omt - compass orientation) <br /> <br />. <br /> <br />Version 8 <br />For Florida residences only <br /> <br />EnergyGauge@ FLRCPB v4.5 <br /> <br />Page 2 <br />