<br />I I <br /> <br />/~ <br />A~f<.A y- ENOl INEE~ ING INC. <br />SfRUCfURAL ~NGIN~~RS <br /> <br />April 1, 2007 <br /> <br />Randy atson Designs, Inc. <br />13821 .S. Highway 98 By-Pass <br />Dade C ty, Florida 33525 <br /> <br />Attent on: Randy Watson <br /> <br />Re: BI ssing Insurance Remodel - Zephyrhills, FL <br />Ar ay Engineering, Inc. Job # 10233 <br /> <br />Dear R ndy: <br /> <br />This I tter is a written confirmation of our telephone conversations <br />regard ng a field revision to the above referenced project. <br /> <br />At the stairway area of the building, the exterior gable end wall can <br />be con tructed as a single story block wall with a 2" X 8" (#2 spruce) <br />stud u per wall (space the studs at 16" on center). Cover the frame <br />wall w th 1/2" plywood sheathing nailed with 8d nails spaced at 3" on <br />center along all horizontal joi,nts & edges, 6" on center along all <br />vertic I joints & edges and 12" on center in the field. <br /> <br />Anchor the P.T. bottom plate to the top of the block wall with 1/2" X <br />8" J-b Its or 1/2" X 7" redhead expansion anchors spaced at 24" on <br />center Lath and stucco the gable end wall as shown on the construction <br />plans o"match the existing building. <br /> <br />If you need any further assistance with these items, please give me a <br />call a the office. <br /> <br /> <br />Inc. <br /> <br />P.E. <br /> <br />~WY. '16 NORfH - SUlfE' #5 LAKE'LAND, FLORIDA 3360Q <br />PHONE': 663-653-2711 FAX: 663-616-2116 <br />Sf A E'. OF FLORIDA CE'RfIFICAfE' OF AUfHORIZAflON # E'B6347 <br />ICHARD L. KIDDE'Y, P.E'. - FLORIDA L1CE'NSE' # 372'16 <br />