Laserfiche WebLink
<br />F <br /> <br /> I <br />O~~ 6UO} -2004R EnergyGaug~ 4.5 <br />. Code Compliance Checklist <br /> RE sidential Whole Building Performance Method A - Details <br />r ADORES S: ,Zephyhills, FL, PERMIT #: 1 <br />6A-21 INFII TRATION REDUCTION COMPLIANCE CHECKLIST <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windc Ws & Doors 606.1.ABC.1.1 Maximum:.3 cfmIso.ft. window area; .5 cfmIsa.ft. door area. <br />Exterior & Adjl ~nt Walls 606.1.ABC.1.2.1 Caulk. gasket, weatherstrip or seal between: windows/doors & frames. surrounding wan; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility <br /> penetrations; between wan panels & toplbottom plates; between walls and floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealed to. the foundation to the too plate. <br />Floors 606. 1.ABC. 1.2.2 Penetrations/openings >118" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter oenetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts. chases, <br /> soffits, chimneys. cabinets sealed to continuous air barrier; gaps In gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barner is <br />-- installed that is sealed at the oerimeter at oenetrations and seams. <br />Recessed Ug~ ~ng Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated. installed inside a <br /> sealed box with 112" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> conditioned sosce, tested. <br />Multi-storv HOl BeS 606.1.ABC.1.2.5 Air barrier on oerimeter of floor cavity between floors. <br />Additionallnfilt ration reqts 1606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA. <br /> have combustion air. <br />6A-22 OTH ~R PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />~PONENT SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir <br /> breaker (electric) or cutoff (aas) must be Droyided. External or built-in heat traD recuired. <br />Swimming Poc s & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiency of 78%. <br />Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts. fittings. mechanical equipment and plenum chambers shaH be mechanically <br /> attached, sealed, insulated. and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />~_Control! 607.1 Separate readily accessible manual or automatic thennostat for each sYStem. <br />Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. I <br />EnergyGauge T DCA Fonn 6OQA-2004R EnergyGauge4M=laRES'2004 FLRCSB v4.5 <br />