Laserfiche WebLink
<br />i I <br /> <br />JeldjWen, Inc. <br /> <br />NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED <br /> <br />A. DRAWINGS <br />1. Manufacturer's die drawings and sections. <br />2. Drawing No. S-2038, titled "Wood stile & rail door" Sheets 1 through 9 of 9, prepared <br />by manufacture dated 07/24/00 and last revised on 08-22-2005, signed and sealed by <br />James Dobrowski, P.E. <br /> <br />B. TESTS (transferred from file #02-0722.09) Test conducted per SFBC, PA202-94, now <br />termed as FBC, TAS 202-94. <br />1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 <br />2) Uniform Static Air Pressure Test, Loading per FBC, T AS 202-94 <br />3) Water Resistance Test, per FBC, T AS 202-94 (Not performed) <br />4) Forced Entry Test, per FBC 2411 3.2.1 (b) and TAS 202-94 <br />Along with marked-up drawings and installation diagram of single glazed Inswingl <br />outs wing wood doors with sidelites, prepared by Certified Testing Laboratories, Test <br />Report No. CTLA572W, and 572WB dated July 10-11,2000 and August 10,2000 <br />respectively and both revised on May 17th, 2001, signed and sealed by Rarnesh Patel, <br />P.E. (Note: The above test reports have been revised by addendum letter dated July 12, <br />2005, issued by Certified Testing Laboratories) <br />2. Additional test report No CfLA 701W for muntin qualification dated June 08, 2001, <br />signed and sealed by Ramesh Patel, P .E. <br /> <br />C. CALCULATIONS (transferred from file #02-0722.09) <br />1. Wood strength referenced properties data from, "w ood Handbook" and table prepared <br />by manufacturer <br />2. Photocopies of anchor verification calculations, dated 7-26-00 prepared, signed and <br />sealed by Mark Fetherman, P.E. <br /> <br />D. QUALITY ASSURANCE <br />1. Miami Dade Building Code Compliance Office (BCCO). <br /> <br />E. MATERIAL CERTIFICATIONS <br />1. None <br /> <br />E. STATEMENTS (transferred from file #02-0722.09) <br />1. Addendum letter dated July 12, 2005; issued by Certified Testing Lab, clarifying in- <br />swing bolts installation for test reports # CTLA572W, CTLA570W & CTLA572W A. <br />2. Statement letter of conformance, "No financial interest" and manufacturing remains <br />the same as original dated July 24, 2000, signed & sealed by James J. Dobrowski, P.E <br />3. Photocopies of Statement letter of conformance, dated October 2, 1999, signed and <br />sealed by Mark C. Fetherman, P .E. <br /> <br />\ ~~'l ). L~1It~ <br />Ishaq I. Chanda, P. E. <br />Product Control Examiner <br />NOA No 04-1025.05 <br />Expiration Date: September 20, 2010 <br />Approval Date: September 22, 2005 <br /> <br />E-l <br />