Laserfiche WebLink
<br />,~aW80n Industry. Inc. <br /> <br />NOTICE OF ACCEPTANCE: EVIDENCE SUBMl'ITED <br />(For File ONLY. . Not pari of NO A.) <br /> <br />~. <br /> <br />DRAWINGS <br />1. Manufacturer's die drawings and sections. <br />2. Drawing No. LTU~7500, dated 11/21/02, with revision #3 dated 02/12/03, titled <br />"Series-7500 Single Hung", sheets 1 through 7, prepared by manufacturer, signed <br />and sealed by Thomas J. Sotos, P .E. <br /> <br />~. <br /> <br />TESTS <br />1. Test reports on: 1) Air Infiltration Test, per P A 202~94. <br />2) Uniform Load Static Air Pressure Test, per PA 202~94. <br />3) Water Resistance Test, per P A 202-94. <br />4) Forced Entry Resistance Test, per AAMA 1302.5-76. <br />along with marked-up drawings and installation diagram of a heavy duty <br />aluminum single hung window glazed with 3/16" annealed glass. prepared by <br />Fenestration Testing Laboratory, Inc. Test Report No. FTL-1890, dated 12/17/97 <br />reissued on 02/09/98, signed and sealed by Gilbert Diamond, P .E. for the <br />following tests: <br />2. Test reports on: 1) Air Infiltration Test, per P A 202-94. <br />2) Uniform Load Static Air Pressure Test, per P A 202-94. <br />3) Water Resistance Test, per P A 202-94. <br />4) Forced Entry Resistance Test, per AAMA 1302.5-76. <br />along with marked-up drawings and installation dia.gram of a fin frame, heavy <br />duty aluminum single hung window glazed with 3/16" annealed glass, marked-up <br />prepared by Fenestration Testing Labomtory, Test Report No. FTL-1891,dated <br />12/23/97 reissued on 02/09/98, signed and sealed by Gilbert Diamond, P.E. <br />3. . Test reports on: 1) Uniform Load Static.Air Pressure Test. per P A 202-94. <br />along with marked-up drawings and installation diagram of a flange :frame, <br />standard rail aluminum single hung window glazed with 3/16" annealed glass, <br />prepared by Fenestration Testing Laboratory Test Report No. FI'L-1892, dated <br />12/29/97 reissued on 02/09/98, signed and sealed. by Gilbert Diamond, P.E. <br />4. Test reports on: 1) Uniform Load Static Air Pressure Test. per P A 202-94. <br />along marked-up drawings and inst811ation diagram of a flange frame, standard <br />rail aluminum single hung window glazed with 1/8" annealed glass, prepared by <br />Fenestration Testing Laboratory, Test report No. FTL-1893 dated 12/29/97 <br />reissued on 02/09/98, signed and sealed by Gilbert Diamond,P.E. <br /> <br /> <br />E-l <br /> <br />anutll Pe <br />Produet Control E <br />NOA No 02- 3.02 <br />Expiration Date: December 10, 2006 <br />Approval Date: March 6, 2003 <br />