My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
07-6660
Zephyrhills
>
Building Department
>
Permits
>
2007
>
07-6660
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:35:11 PM
Creation date
10/30/2007 12:44:04 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-6660
Building Department - Name
KEARSE,GENEVA
Address
4734 16TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />EVALUAT ON ENTITY Product Evaluation Report MANUFACTURER <br />Gary Pfuehl r, P. E. Clopay Building Products Company <br />5665 Green )ak Comt for Florida DCA 8585 Duke Blvd. <br />Fairfield, 01 45014 Mason, OH 45040 <br /> Evaluation Report # 4050W3-09 513.770.4800 <br /> Statement of Comoliance: <br />The Clopay Building Products Company sectional doors as described on the drawings listed below meet the design <br />and test pressures shown. Based on the testing and rational analysis detailed below, this product is evaluated to be in <br />con pliance with the following provisions of the Florida Building Code: <br />00 Outsid the HVHZ: 1606.1 Wind Loads (tested in compliance with FRC 1707.4.3.1, ref. ANSI/DASMA 108 orTAS 202) <br />o Inside he HVHZ: 1619 Wind Loads for HVHZ (tested in compliance with FBC 1707.4.3.1, ref. TAS 202), <br />16 5 Cyclic Tests for HVHZ (ref. TAS 203), 1626 Impact Tests for HVHZ (ref. TAS 201) <br />Description of Product: Double-skin Insulated (exterior skin 27 ga. min.; interior skin 29 ga. min.) <br />Single-Car (up to 9'0" wide) WINDCODE@W3 Garage Door <br /> Desi~n Pressures: +20/-20 Test Pressures: +30/-30 <br />Specific Me dels and Technical Documentation: <br />Mocel Test Reoort Drawinl! No. Comments <br />2050W3, 051W3, Glazing approved per HCN-19A, HCN-9, HCN-5A. Low head room <br />2053W3, 050W3, HCN-23A 10 1655 Rev06 track approved per HCN-126. <br />4051 W3, 053W3 <br />62W3,64\1 3, 65W3 HCN-23A 102044 Rev03 Glazing approved per HCN-19A, HCN-9, HCN-5A. Low head room <br />track approved per HCN-126. <br />DP38W3, L38W3, Glazing approved per HCN-19A HCN-9, HCN-5A. Low head room <br />134W3, 35W3, HCN-23A 102129 Rev03 <br />136' "3 track approved per HCN-126. <br />Installation relluirements: Installation must be in accordance with manufacturer's ,installation instructions. <br />Limitation and conditions of use: Jambs, lintels, sills or other structural elements required to prepare openings are not covered_ <br />The design fthe suppOIting structural elements shall be the responsibility of the professional of record for the building or structure <br />and in acco dance with current building codes for the loads listed on the drawing referenced above. <br />Certificati~ n ofIndelJcndence of Evaluation Entitv: I hereby certi fy that (I) I have no financial interest in Clopay Building <br />Products Cc mpany; (2) J am an independent licensed Professional Engineer in the State of Florida; and (3) 1 comply with the criteria <br />of independ nce as stated in 98-72.110 F.A.C. <br />Signature: ~eL- <br /> Florida P. E. No. 49850 <br />Date: S7'zp/(" <br /> <br />FILE: 4050W3-09 REv02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.