<br />'I I <br /> <br />FORM 600'A-2004 EnergyGauge@4.0 <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br />Florida Department of Community Affairs <br />Residential Whole Building Performance Method A <br />Project Name: Siesta Key, Builder: -' ~ I <br />Address: : ~" ~~"'~ o<:n. 6",+;!J. "'!> Pennitting Office: Oilf' if,~ <br />City, State:'7..dfIl-Y (~/. .. . . .-.- . Pennit Number: f . eocf' wi' 0'1 <br />Owner: US Homes ' 3;750.\'2.. UoJ, \Jo... \e\[,,"" Jurisdiction Number: 10 //6t:!JO I <br />Climate Zone: Central l:1 20 -~ . <br /> <br />l. <br />2. <br />3 <br />4. <br />5. <br />6. <br />7. <br /> <br />New construction or existing <br />Single family or multi-family <br />Number of umts, if multi-family <br />Number ofBddrooms <br /> <br />New <br />Single family <br />1 <br />2 <br /> <br />Is this a worst case? Yes <br />Conditioned floor area (iF) 1583 iF <br />Glass type I and area: (Label reqd. by 13-104.4.5 ifnot default) <br />a. U-factor: Description Area <br />(or Single or Double DEFAULT) 7a. (Sngle Default) 115.0 fF <br />b. SHGC: <br />(or Clear or Tint DEF AUL T) <br />8. Floor types <br />3. Slab-On-Gomde Edge Insulation <br />b. N/A <br />c. N/A <br />9 . Wall types <br />a. Frame, Wood, Exterior <br />b. Concrete, Int Insul, Exterior <br />c. N/A <br />d. N/A <br />e. N/A <br />10. Ceiling types <br />a. Under Attic <br />b. N/A <br />c. N/A <br />11. Ducts <br />a. Sup: Con. Ret: Con. AH: Interior <br />b. N/A <br /> <br />7b. <br /> <br />(Clear) 115.0 fP <br /> <br />R~--o.O, 288.O(p) ft <br /> <br />R~Il.O, 1184.0 fP <br />R=40, 1022.0 ft2 <br /> <br />R=I9.0, 1583.0 fP <br /> <br />Sup. R=6.0, 55.0 ft <br /> <br />12. Cooling systems <br />a. Central Unit <br /> <br />Cap: 26.0 kBtulhr <br />SEER: 13.00 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />13. Heating systems <br />a. Electric Heat Pump <br /> <br />Cap: 26.0 kBtulhr <br />HSPF: 7.50 <br /> <br />b. N/A <br /> <br />c. N/A <br /> <br />14. Hot water systems <br />a. Electric Resistance <br /> <br />Cap: 40.0 gallons <br />EF: 0.92 <br /> <br />b. N/A <br /> <br />c. ConselVation credits <br />(HR-Heat recovery, Solar <br />DHP-Dedicated beat pump) <br />15. HV AC credits <br />(CF-Ceiling fan, CV--Cross ventilation, <br />HF-Wbole bouse fun, <br />PT -Programmable Thermostat, <br />MZ--C-Multizone cooling, <br />MZ-H-Multizone heating) <br /> <br />Glass/Floor Area: 0.07 <br /> <br />Total as-built points: 16408 <br />Total base points: 20099 <br /> <br />I hereby certifY that the plans and specifications covered by <br />this calculation anAiS~ . rida Energy <br />Code. AIR D, NING & <br />PREPARED BY <br /> <br />DATE: <br /> <br /> <br />1 Predominant <br /> <br />PASS <br /> <br /> <br />Review of the plans and <br />specifications covered by this <br />calculation indicates compliance <br />with the Florida Energy Code. <br />Before constroction is completed <br />this building will be inspected for <br />oomplianoe ...h Seclion 553'~ <br />Florida Statutes. . . go <br />BUILDING OF Ie L: ~ '{( ( h J <br />DATE: tl fc. <br /> <br />type. For actual glass type and areas, see SUmmer & Wtnter Glass output on pages 2&4. <br />EnergyGauge4S> (Version: FLRCSB v4.0) <br /> <br /> <br />._~..~. <br />....;.. <br />