<br />Code Compliance Checklist
<br />esidential Whole Building Performance Method A - Details
<br />
<br />
<br />PERMIT #:
<br />
<br />6A-21 IN....IL TRATION REDUCTION COMPLIANCE CHECKLIST
<br />COMPONE NTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK
<br />Exterior WI dows & Doors 606,1.ABC.1.1 Maximum:.3 cfm/sq.ft, window area; .5 cfm/sq.ft. door area.
<br />Exterior & djacent Walls 606,1.ABC.1,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
<br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br /> penetrations; between wall panels & top/bottom plates; between walls and floor.
<br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br /> from, and is sealed to, the foundation to the top plate.
<br />Floors 606,1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members.
<br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br /> to the perimeter, penetrations and seams.
<br />Ceilings 606.1.ABC,1.2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br /> installed that is sealed at the perimeter, at penetrations and seams.
<br />Recessed ~ighting Fixtures 606.1.ABC.1,2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
<br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from
<br /> conditioned space, tested.
<br />MUlti-stOry~ouses 606,1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.
<br />Additional I. filtration reqts 606,1,ABC.1,3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
<br /> have combustion air,
<br />6A-22 0 HER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
<br />COMPON~ NTS SECTION REQUIREMENTS CHECK
<br />Water Hea brs 612.1 Comply with efficiency requirements in Table 612,1,ABC,3.2. Switch or clearly marked cir
<br /> breaker (electric) or cutoff (gas) must be provided. External or built-in heat trap required.
<br />Swimmingj:>ools & Spas 612.1 Spas & heated pools must have covers (except solar heated), Non-commercial pools
<br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal
<br /> efficiency of 78%.
<br />Showerhe~ds 612,1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG.
<br />Air Distribu ,ion Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
<br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
<br /> Ducts in unconditioned attics: R-6 min. insulation.
<br />HVAC Contois 607.1 Separate readily accessible manual or automatic thermostat for each system.
<br />Insulation 604.1, 602.1 Ceilings-Min, R-19, Common walls-Frame R-11 or CBS R-3 both sides,
<br /> i Common ceiling & floors R-11.
<br /> !
<br />
<br />"
<br />
<br />EnergYGaubetM DCA Form 600A-2004