Laserfiche WebLink
<br />I I <br /> <br />FORM 600A-2004 <br /> <br />EnergyGauge@4.0 <br /> <br />Code Compliance Checklist <br />. Residential Whole Building Performance Method A - Details <br /> <br />Multi-story ouses <br />Additional I filtration reqts <br /> <br />I ADDR SS:", <br /> <br />6A-21IN ILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPON~ J-.nS SECTION REQUIREMENTS FOR EACH PRACTICE <br />Exterior Wi dows & Doors 606,1,ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area, <br />Exterior &) djacent Walls 606.1,ABC,1,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br />foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br />penetrations; between wall panels & top/bottom plates; between walls and floor, <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />from, and is sealed to, the foundation to the top plate. <br />606,1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members, <br />EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />to the perimeter, penetrations and seams. <br />606,1.ABC.1.2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />installed that is sealed at the perimeter, at penetrations and seams. <br />Recessed Ulghting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br />I <br />sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from <br />conditioned space, tested. <br />606.1,ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. <br />606.1,ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br />have combustion air. <br /> <br />PERMIT #: <br /> <br />I <br /> <br />CHECK <br /> <br />Floors <br /> <br />Ceilin9s <br /> <br />i <br />I <br />I <br />Showerhe~ds <br />Air Distribu10n Systems <br /> <br />I <br />I <br />HVAC contOIS <br />Insulation i <br />j <br /> <br />6A-22 0 HER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONE INTS SECTION REQUIREMENTS <br />Water Hea l;lrs 612.1 Comply with efficiency requirements in Table 612.1,ABC,3.2, Switch or clearly marked cir <br />breaker (electric) or cutoff (gas) must be provided, External or built-in heat trap required. <br />Spas & heated pools must have covers (except solar heated), Non-commercial pools <br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />efficiency of 78%. <br />Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG, <br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br />Ducts in unconditioned attics: R-6 min. insulation. <br />Separate readily accessible manual or automatic thermostat for each system. <br />Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br />Common ceiling & floors R-11. <br /> <br />CHECK <br /> <br />Swimming ools & Spas <br /> <br />612.1 <br /> <br />612,1 <br />610.1 <br /> <br />607.1 <br />604.1,602.1 <br /> <br />I <br /> <br />EnergYGaule ™ DCA Form 600A-2004 <br /> <br />EnergyGauge@/FlaRES'2004 FLRCSB v4,O <br />