<br />FORM 600A-2004
<br />
<br />EnergyGauge@4.0
<br />
<br />Code Compliance Checklist
<br />. Residential Whole Building Performance Method A - Details
<br />
<br />Multi-story ouses
<br />Additional I filtration reqts
<br />
<br />I ADDR SS:",
<br />
<br />6A-21IN ILTRATION REDUCTION COMPLIANCE CHECKLIST
<br />
<br />COMPON~ J-.nS SECTION REQUIREMENTS FOR EACH PRACTICE
<br />Exterior Wi dows & Doors 606,1,ABC.1.1 Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area,
<br />Exterior &) djacent Walls 606.1,ABC,1,2,1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall;
<br />foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility
<br />penetrations; between wall panels & top/bottom plates; between walls and floor,
<br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends
<br />from, and is sealed to, the foundation to the top plate.
<br />606,1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members,
<br />EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed
<br />to the perimeter, penetrations and seams.
<br />606,1.ABC.1.2,3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases,
<br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate;
<br />attic access, EXCEPTION: Frame ceilings where a continuous infiltration barrier is
<br />installed that is sealed at the perimeter, at penetrations and seams.
<br />Recessed Ulghting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a
<br />I
<br />sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2,0 cfm from
<br />conditioned space, tested.
<br />606.1,ABC.1.2.5 Air barrier on perimeter of floor cavity between floors.
<br />606.1,ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA,
<br />have combustion air.
<br />
<br />PERMIT #:
<br />
<br />I
<br />
<br />CHECK
<br />
<br />Floors
<br />
<br />Ceilin9s
<br />
<br />i
<br />I
<br />I
<br />Showerhe~ds
<br />Air Distribu10n Systems
<br />
<br />I
<br />I
<br />HVAC contOIS
<br />Insulation i
<br />j
<br />
<br />6A-22 0 HER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.)
<br />COMPONE INTS SECTION REQUIREMENTS
<br />Water Hea l;lrs 612.1 Comply with efficiency requirements in Table 612.1,ABC,3.2, Switch or clearly marked cir
<br />breaker (electric) or cutoff (gas) must be provided, External or built-in heat trap required.
<br />Spas & heated pools must have covers (except solar heated), Non-commercial pools
<br />must have a pump timer. Gas spa & pool heaters must have a minimum thermal
<br />efficiency of 78%.
<br />Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG,
<br />All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically
<br />attached, sealed, insulated, and installed in accordance with the criteria of Section 610.
<br />Ducts in unconditioned attics: R-6 min. insulation.
<br />Separate readily accessible manual or automatic thermostat for each system.
<br />Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides.
<br />Common ceiling & floors R-11.
<br />
<br />CHECK
<br />
<br />Swimming ools & Spas
<br />
<br />612.1
<br />
<br />612,1
<br />610.1
<br />
<br />607.1
<br />604.1,602.1
<br />
<br />I
<br />
<br />EnergYGaule ™ DCA Form 600A-2004
<br />
<br />EnergyGauge@/FlaRES'2004 FLRCSB v4,O
<br />
|