Laserfiche WebLink
<br />RlGHf-J CALCULATION PROCEDURES A, B, C, D <br /> <br />J b #: Siesta Key <br />-Z ne: Entire House <br />P;ocedureA - Winter Infiltration HIM CaIculation* <br /> <br />File name: <br /> <br />11/29/05 <br />Danbury:rsr <br /> <br />1. - Winter Infiltration CFM <br />1 . 2 ACIHR x <br /> <br />o Cu.Ft. x 0.0167 = <br /> <br />o <br /> <br />CFM <br /> <br />2. Winter Infiltration Btuh <br />1.1 x 0 CFMx <br /> <br />3 0 Winter 1D = <br /> <br />o <br /> <br />Btuh <br /> <br /> <br />3. Winter Infiltration HIM <br />o Btuh I <br /> <br />157 <br /> <br />Total Window = <br />and Door Area <br /> <br />0.0 <br /> <br />H1M <br /> <br />ocedure B - Summer Infiltration'HIM Calculation* <br /> <br />1. Summer Infiltration CFM <br />o . 5 ACIHR x <br /> <br />o CU.Ft. x 0.0167 = <br /> <br />o <br /> <br />CFM <br /> <br />2. Summer Infiltration Btuh <br />1.1 x 0 - CFM x <br /> <br />2 0 Summer 1D = <br /> <br />o <br /> <br />Btuh <br /> <br />3. Summer Infiltration HIM <br />o Btuh I <br /> <br />157 <br /> <br />Total Window = <br />and Door Area <br /> <br />0.0 <br /> <br />H1M <br /> <br /> <br />ocedure C - Latent Infiltration Gain <br /> <br />0.68 x <br /> <br />54 gr.diff. x <br /> <br />o <br /> <br />CFM = <br /> <br />o <br /> <br />Btuh <br /> <br />ocedure D - Equipment Sizing Loads <br /> <br />1. Sensible Sizing Load <br /> <br />Sensible Ventilation Load <br />1.1 x 0 Vent.CFM x <br />Sensible Load for Structure (Line 19) <br />Sum of Ventilation and Structure Loads <br />Rating and Temperature Swing Multiplier <br />Equipment Sizing Load - Sensible <br /> <br />20 Summer 1D 0 Btuh <br />+ 20671 Btuh <br /> 20671 Btuh <br />x 1.00 RSM <br />+ 20671 Btuh <br /> <br />2. Latent Sizing Load <br /> <br />Latent Ventilation Load <br />0.68 x 0 Vent.CFM x <br />Internal Loads = 2 3 0 x <br />Infiltration Load From Procedure C <br />Equipment Sizing Load -Latent <br /> <br />5 4 gr.diff. <br />4 . No. People <br /> <br />+ <br />+ <br /> <br />-0 Btuh <br />920 Btuh <br />o Btuh <br />9 2 0 Btuh <br /> <br />Construction Quality is: <br /> <br />a <br /> <br />No. of Fireplaces is: <br /> <br />o <br /> <br />AL J:. 7th Ed. <br /> <br />Right-Suite: <br /> <br />Ver 4.1. 27 <br /> <br />SIN <br /> <br />RSR2102,l <br /> <br />Printout certified by ACCA to meet all requirements of Manual Form J <br />