My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
07-6752
Zephyrhills
>
Building Department
>
Permits
>
2007
>
07-6752
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:34:42 PM
Creation date
1/4/2008 9:39:13 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-6752
Building Department - Name
1ST PREBRYTERIAN CHU
Address
5510 19TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />_,_', "icr:ti<.",~----- <br /> <br />~~i <br />E \_) t . -. 3 <br />,,'...,-~.._~~.,-:- E <br /> <br />,.,....... Report <br />Fire Alarm <br /> <br />q 11 "lq81l~~)ntDate: <br /> <br />6/26/2007 <br /> <br />-~~:;; :~ <br /> <br />Zephyrhills Fire Rescue <br />6907 Dairy Rd <br />Zephyrhills, 33542 <br />Phone: 813-780-0041 <br />Fax:813-78~044 <br /> <br />Inspection Date: 6/26/2007 6:00:00PM <br />InspectorName: Kerry Barnett <br />InspectionNumber: 1-113-07-0437 <br />InspectionCause: Periodic <br /> <br />InSDected Partv <br />FIRST PRESBYTERIAN CHURCH <br />(000284) <br />5510 19th ST <br />ZEPHYRHILLS, FL 33542 <br />Phone: 813-782-7412 <br /> <br />Acceptance Test <br /> <br />OccupancyType: Assembly <br />PropertyUseType: Places of Worship <br />ViolationCounts: 1 <br />Hrs: 0 <br /> <br />violation <br /> <br />Notice: Correct Immediately <br /> <br />Ref. Number: NFPA 101 (2003) 9.6 Fire Detection, Alarm, and Communication Systems 9.6.1.3 Fire Detection, Alarm, and <br />Communications Systems. <br />A fire alarm system required for life safety shall be installed, tested, and maintained in accordance with the applicable <br />requirements of NFPA70, National Electrical Code4!l, and NFPA72B>, National Fire Alarm Code4!l, unless it is an approved existing <br />installation, which shall be permitted to be continued in use. <br />Comment: Change out all homs to hom strobes and add additional strobes to fellowship hall and kitchen. This is due to the poor <br />condition of exsisting devices. <br /> <br />Install/verify that a detector is located in all storage related areas. <br /> <br />Label batteries and date. Right side battery did not activate a trouble alarm. <br /> <br />Inside control panel write electric panel number and breaker number. Also lock fire alarm breaker in electric panel. <br /> <br />Telephone line disconnect shall go into a trouble, not full alarm. <br /> <br />Alarm did not dial out. Also provide cerlificate of UL listed central station. <br /> <br />Verify hood system is tied to alarm. <br /> <br />Provide a alarm book at control box that will contain zone map showing all pull station and detector location, sign in section for <br />alarm work and testing, copy of cerlificate and section for all alarm reporls. <br /> <br />A 100% acceptance test shall be conducted prior to reinspect. <br /> <br />Comments: <br />Not approved at this time. Call for reinspect. Additional fee will be assessed at reinspect for system acceptance. <br /> <br />Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.