Laserfiche WebLink
<br />, . <br /> <br />-\ <br /> <br />.' . <br /> <br />G-250 <br /> <br />@) Fire-UTe" ALarms <br /> <br />March 3D, 2000 <br /> <br />SpectrAlert ™ Series <br />Horns, Strobes, and Horn/Strobes <br /> <br />GENERAL <br /> <br />Section: AudioNisual Devices <br /> <br />System Sensor SpectrAlert Series strobes, horns, and combina- <br />tion hornlstrobes are UL listed for primary signaling in life safety <br />systems and meet ADA public mode visible signaling requirements. <br /> <br />SpectrAlert products can be connected to the alarm indicating cir- <br />cuit of a fire alarm control panel and are compatible with DC line <br />supervision. The SpectrAlert product line mounts to standard <br />backboxes using a universal mounting plate included with each unit. <br />An optional small footprint mounting plate fits to a single-gang box. <br />An accessory backbox skirt gives a cosmetic finish to a 4" x 4" x <br />1-1/2" or a 2" x 4" x 1-7/8" surface-mounted backbox. All strobe <br />and hornlstrobe mounting options require only one screw attach- <br />ment of product to plate. <br /> <br />These products are designed for 12 and 24 VDC and full-wave rec- <br />tified unfiltered power. Full-wave rectified operation requires more <br />current than DC operation. For detailed current draw information, <br />consult the Current Draw Tables (page 2). The hornlstrobe com- <br />bination products are factory-assembled with jumper wires for in- <br />tandem operation. For independent wiring of hom and strobe, re- <br />move jumper wires. When wired for independent operation, the <br />strobe will continue to run while the horn can be silenced. How- <br />ever, the strobe must be running for horn to operate. <br /> <br />Horns - The SpectrAlert Series horns and homlstrobes pro- <br />vide two different field-selectable/reversible tones. a high-low field- <br />selectable/reversible sound output setting (low setting on 24-volt <br />models only) and a field-selectable/reversible temp 3 pattern or <br />non-temporal continuous pattern. These field-selectable features <br />are accomplished using pins and jumpers located on the back of <br />each SpectrAlert horn and hornlstrobe. An accessory module is <br />not needed to make these field selections. The hom on hornlstrobe <br />models will operate on a coded power supply. Those horn-only <br />models with "He" in their part numbers will also operate on a <br />coded power supply. The horn and hornlstrobe series includes <br />weatherproof models. <br /> <br />Strobes - The ADA-compliant SpectrAlert strobes are elec- <br />tronic visible warning signals that flash at 1 Hz over their operating <br />voltage range. These products are available in 24-volt models at <br />15, 15/75, 75 and 11-0 candela intensities and in 12-volt models at <br />15 and 15/75 candela intensities. The strobe series includes weath- <br />erproof models. SpectrAlert products feature dramatic reductions <br />in current requirements. <br /> <br />Sync-Circuit Module (MDL) - The Sync-Circuit Module <br />is available for synchronization of strobes and horns and can syn- <br />chronize two Style Y (class B) circuits or one Style Z (class A) <br />circuit. The module can also generate a synchronized temp 3 tone <br />for System Sensor's Multi-Alert™ and PA400 hom products.' The <br />synchronization module allows the SpectrAlert homs on combina- <br />tion horn/strobes to be silenced on two-wire systems. SpectrAlert's <br />Sync-Circuit Module can be daisy-chained for multiple zone syn- <br />chronization. The module does not operate on a coded power sup- <br />ply. <br /> <br />"For Multi-Alert and PA400: Strobes must be wired to a continuous <br />source of power (non-coded power supply). <br /> <br />@L.....S4011&55512(P1215,P121575,P2415, <br />(!; P241575. P2475. P24110). S5512 (51215, <br />5121575,52415,5241575,52475,524110). <br /> <br />LISTED S4011 (HCi2I24). <br /> <br /> <br />@ ..... CS549 (P2415A, P241575A, P2475A. P24110A, <br />52415A, 5241575A. 52475A. 524110A). <br />U LC CS548 (H12124A, HC12124A). <br /> <br /> <br />OB8A4.AY (P1215. P121575, ~ ~ <br />P2415, P241575, P2475. P24110, ~ <br />51215.5121575.52415,5241575, <br />52475,524110, H12124). OD4A7.AY (HC12124). <br /> <br /> <br />..... 7135-1209:173 (P1215, P121575, P2415. <br />P241575, P2475, P24110). <br />7125-1209:174 (51215, 5121575. <br />52415.5241575,52475.524110). <br />7135-1209:143 (H12124, HC12124). <br /> <br />California <br />State Fire <br />Marshal <br /> <br />MEA..... 319-96-E (P1215, P121575, <br />P2415. P241575. P2475, <br />P24110,S1215,S121575, <br />52415,5241575,52475, <br />524110, H12124. HC12!24). <br /> <br /> <br />- .- <br />._- <br /> <br />F!E.E <br /> <br />I <br />I: <br />. <br />I <br />. <br />I <br />( .~ <br />. ........ <br />.. ""- I ..,-" <br />~ 1'. t~i..._oi." _ <br />: H~~~r'H ~ <br />~. tt .~--". :;.;, ......\ ~ <br />.~~.~ -~~-.-.~ . <br />'. <br /> <br />SpectrAlert™, Sync'Circuit'M, and Multi-Alert™ are trade- <br />marks of System Sensor, a division of Pittway Corporation. <br /> <br />This document is not intended 10 he used for Installation purposes. We try to keep our product information <br />up.to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All speci- <br />fications are subject to change without notice. For more information, contact Fire-Lite Alanns, One Fire. <br />Lite Place. Northford. Connecticut 06472. Phone; (800) 627.3473. Toll Free FAX; (8n) 699-4105. FAX <br />BacI<;(888) 388-3299 <br />WEB: WYNI.firelite.com <br /> <br />ISO 9001 <br /> <br />K: -...J =I :.. .. . :::II . ~ '.] <br />ENGINEERIN; & MANUFACTUBING <br /> <br />OF-S16D9 - Page 1 of 6 <br />