Laserfiche WebLink
<br />VVood.~on-InsU1ated <br /> <br />Min 19/32," thick plywood attached using approved nails ~'Paced 4" o.c. at wood <br />joists spaced max. 24" O.c. <br /> <br />System Type E(2): Base sheet mechanically fastened <br /> <br />All General and System Limitations apply. <br /> <br />Separation Sheet: (Optional) One or more layers of GlasBase, loose laid. <br /> <br />AnchorlBase Sheet: One or more layers ofFJintlastic SA NailBase, mechanically attached as <br />described below. <br /> <br />AnchorlBase sheet shall be fastened with approved. 11 gauge l-W~ annular ring- <br />shank roofing nails and tin caps spaced 8" o.c. at the min. 3" wide sidelap. <br />With three additional (equally spaced) staggered. rows in the center of the sheet <br />spaced 8 inches o.c. for a total of four rows. <br /> <br />(Optional) One or more layers of Flintlastic SA'Mid Ply, self-adhered <br /> <br />One or more layers of Flintlastic SA Cap, self-adhered <br /> <br />NODe <br /> <br />Deck Type 1: <br />Deck Description: <br /> <br />Fastening: <br /> <br />Ply Sheet: <br />Membrane: <br /> <br />Surfacing; <br /> <br />Maximum Design <br />Pressure: <br /> <br />I <br /> <br />-60 psf (See General Limitation. #7.) <br /> <br />NOA No.: 04-0623.01 <br />ExpIratIon Date: 04/13/1. 0 <br />Approval Date: 04/13/05 <br />PAge 6 of7 <br />