<br />Tested sealed ducts must be certified in this house.
<br />
<br />ENERGY PERFORMANCE LEVEL (EPL)
<br />DISPLAY CARD
<br />
<br />ESTIMATED ENERGY PERFORMANCE SCORE* = 88.1
<br />The higher the score, the more efficient the home.
<br />
<br />HOMES OF MERIT""
<br />
<br />I. New construction or existing New
<br />2. Single family or multi-family Single family
<br />3. Number of units, if multi-family I
<br />4, Number of Bedrooms 3
<br />5, Is this a worst case? Yes
<br />6, Conditioned floor area (ft2) 1493 ft2
<br />7, Glass typel and area: (Label reqd, by 13-104.4.5 ifnot default)
<br />a, U-factor: Description Area
<br />(or Single or Double DEFAULT) 7a, (Dble, U=O.3) 75.0 ft2
<br />b, SHGC:
<br />(or Clear or Tint DEFAULT) 7b, (Clear) 124,7 ft2
<br />8, Floor types
<br />a, Raised Wood, Stem Wall R=ll,O, 1493,Oft2
<br />b, N/A
<br />c, N/A
<br />9, Wall types
<br />a. Frame, Wood, Exterior R=19,O, 1363,3 ft2
<br />b, N/A
<br />c, N/A
<br />d. N/A
<br />e, N/A
<br />10, Ceiling types
<br />a, Under Attic R=22,O, 1493,0 ft2
<br />b. N/A
<br />c, N/A
<br />II. Ducts(Leak Free)
<br />a, Sup: Unc, Ret: Unc. AH: Outdoors Sup, R=6,O, 145,0 ft
<br />b, N/A
<br />
<br />12, Cooling systems
<br />a, Central Unit
<br />
<br />Cap: 36,0 kBtulhr
<br />SEER: 13,00
<br />
<br />b, N/A
<br />
<br />c, N/A
<br />
<br />13, Heating systems
<br />a, Electric Heat PumplPackage
<br />
<br />Cap: 36,0 kBtulhr
<br />HSPF: 7,70
<br />
<br />b, N/A
<br />
<br />c, N/A
<br />
<br />14, Hot water systems
<br />a. Electric Resistance
<br />
<br />Cap: 50,0 gallons
<br />EF: 0,90
<br />
<br />b, N/A
<br />
<br />c, Conservation credits
<br />(HR-Heat recovery, Solar
<br />DHP-Dedicated heat pump)
<br />15. HVACcredits
<br />(CF-Ceiling fan, CV-Cross ventilation,
<br />HF-Whole house fan,
<br />PT -Programmable Thermostat,
<br />MZ-C-Multizone cooling,
<br />MZ-H-Multizone heating)
<br />
<br />PT, _
<br />
<br />I certify that this home has complied with the Florida Energy Efficiency Code For Building
<br />Construction through the above energy saving features which will be installed (or exceeded)
<br />in this home before fInal inspection. Otherwise, a new EPL Display Card will be completed
<br />based on installed Code compliant features.
<br />Builder Signature: Date:
<br />
<br />Address of New Home:
<br />
<br />
<br />CitylFL Zip:
<br />
<br />*NOTE: The home's estimated energy peiformance score is only available through the FLA/RES computer program,
<br />This is not a Building Energy Rating, If your score is 80 or greater (or 86 for a us EP A/DOE EnergyStarâ„¢designation),
<br />your home may qualify for energy efficiency mortgage (EEM) incentives if you obtain a Florida Energy Gauge Rating,
<br />Contact the Energy Gauge Hotline at 321/638-1492 or see the Energy Gauge web site at wwwfsec,ucfedufor
<br />information and a list of certified Raters, For information about Florida's Energy Efficiency Code For Building
<br />Construction, contact the Department of Community Affairs at 850/487-1824,