Laserfiche WebLink
<br />Aug. 1. 2001 3:34~M <br /> <br />s r s t I I e <br /> <br />'1 u, L' L J <br /> <br />1. VI V <br /> <br />WOOD DECK SYSTEM LIMITATIONS:, ' <br />1 A slip sheet IS requireQ with' Ply 4 and Ply 6 whe~ used as a mech!lnicallY, fastened base or' anchor <br />sheet. . , ' ' <br /> <br />GENERAL LIMITATIONS; <br /> <br />. , <br />1. Fire classification is not part of this acceptance, l'Ofer to a:current Approved Roofing Materials <br />Directory for fire ratings of this product. ' . ' , <br />2. Insulation may be installed in Inultiple layers. The first layer shall be,attac~ in coIIipliance witl1, <br />Product Control Approval guidelines. All other ~ayers shall be adhered in a full mopping ()f approved <br />asphalt applied within'the EVT'rangt and at a tate of20.40 IbsJsq., or meChanically attached using <br />the fastening pattern of the top layer " " , ' , ' <br />3. , All standard panel sizes' are' acceptable for mechanical attachment. When ~ppli~ in approved <br />asphalt, panel size shall be 4' x' 4' maximum. :. '" ' <br />4. An overlay and!l~r'recovery boai'd insulation panel is requ~ on ,aU applications Over closed cell <br />foam insulations when the base sheet. is fuiIy mopped. If no recovery bOard is used the base sheet <br />, shall be appli~ using spot, mopping' with approved aspha~t, 12", ~i~ter Circles, 24" o.c.; or strip <br />mopped 8" ribbons in three rows, one at each,sidelap a~d,one down, the center of the sheet allowing a <br />continuous area of ventilation: Encircling of the stripS is not ae:ceptable. A 6t~ break shall be placed <br />every 12'.in each ribbon to allow CfOllS ventilation. Asphalt application of either system sball be at 8 <br />minimum rate 0!-12 Ibs./sq. : Note: Spot attached systems shaI1 be limi~ed to a ~um design <br />presSure or -4S p~. , ' , ' ' .,' <br />5. Fastener spacing for insulation attathment is base4 on a Minimum Characteristic Force '(F) value of ' <br />2751bf., as tested in compliance with Testing Application Sl:aJ;1dard TAS 105; If the fastener value, <br />as field-tested, are below 275 Ibf., insulation attachri1ent shall not be acceptable. , ' ' <br />6. Fastener spacing fot 11JeChani~id aWl'Chment of an~horlbase sheet,or ~mbtane attachment is based,' <br />on a minimuni fastener resistance value in cOnjunction with the maximum design v'alue listed within <br />a specific system. Should the fasten~ resistanc~' be iesS"than that requii-ed, as deterlni.ned by the , <br />Building QfficiaI. a'revised fastener spacil;1g, ~pared, signed ~~ sealed' by a Florida Registered <br />Engineer, Architect, or Regislered Roof Consultant may be submit~ed. Said revised fastener spac~g <br />shall utilize the withdrawal,resistance value taken from Testing Applicatjon Standards T AS 105 aild <br />calculations in compliance with Roofing Application Standard RAS 117. <br />7. Perimeter and corner areas shall comply with the enhanced upllft p~sure .requirements of these <br />areas. Fastener ,densities shall 'be increased for bom insulation aild base sheel as calculated in <br />compliance with 'Roofing Appl~cation Standa1:d, RAS 117. (When ~'Iimi~tion is specl6cany <br />referred within this NOA; Getleral ~tati.OJl #9 :will not be .,.pplicabl~) , ' <br />8. All attachment and sizing of peDD;leter nailers, metal profile" and/or flashing termination designs shall <br />, contonn with RoofuigApplication'Standard RAS 111 and applicable w~ load requirements. <br />,9. The ~ designed prel!sui:'e limi~on listed shan be applicable' to all roof pressure zones (i.e; <br />field, perimeters, and comers): Neither r~onal analysis, nor extrapcilati~n shall be pemritted for , <br />enhan~ed fastening at enha~ced pressure zones (i.e. petimetei'&, extended comers and comers). <br />(When this limitation is specifically referred, within this NOA, General Limitation /#7 will not be ' <br />appU~ble.) , .' <br />10. All products listed herem 'shall have a quality assurance audit hi accordance with.' the Florida Building <br />Code and Rule. 9B-72 of the Florida Adp1inistrative Code.' ' <br />END OF TlDS ACCEPTANCE <br /> <br />I <br /> <br />.~6A No.: 03-0514.03 <br />ExpinitioQ Date: 08131/08 <br />Appro:val Dam: 10/08103 <br />, page 8 on <br />