My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
07-7345
Zephyrhills
>
Building Department
>
Permits
>
2007
>
07-7345
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:31:51 PM
Creation date
1/18/2008 9:58:01 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-7345
Building Department - Name
CHILI'S BAR & GRILL
Address
7643 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
16
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />12/14/2007 FRI 15:54 FAX 1813 806 7190 ADT Security Services <br /> <br />~007/008 <br /> <br />e Fire. UTe ALarmS <br />by Honeywell <br /> <br />June 10, 2005 <br /> <br />DF-52004 . F-050 <br /> <br />BG-12 Series <br />Manual Fire Alarm Pull Stations <br /> <br />Section: Conventional Initiating Devices <br /> <br />GENERAL <br /> <br />The Fir8"Llte Alarms BG-12 Series is a cost-effective, fea- <br />ture-packed, non-coded series of manual fire alarm pull <br />stations. It was designed to meet multiple applications <br />with the Installer and end-user in mind. The BO-12 Series <br />features a variety of models Including single- and dual- <br />action versions. <br /> <br />The BO-12 Series provides Fir8"Ute Fire Alarm Control <br />Panels (FACPs), as well as other manufacturers' controls, <br />with a manual alarm initiating Input signal, Its innovative <br />design, durable construction, and multiple mounting op- <br />tions make the 00-12 Series simple to Install, maintain, <br />and operate. <br /> <br />FEATURES <br /> <br />o Aesthetically pleasing, highly visible design/color. <br />o Attractive contoured shape with light textured finish. <br />I Meets ADA 5 lb. maximum pull-force. <br />o Meets UL 38, Standard for Manually Actuated Signaling <br />Boxes. <br />I Easily operated (single- or dual-action), yet designed to <br />prevent false alarms when bumped, shaken, or jarred. <br />PUSH INIPULL DOWN handle latches in the down po- <br />sition to clearly indicate the station has been operated. <br />o The word "ACTIVATED" appears on the top of the handle <br />in bright yellow, further indicating operation of the sta- <br />tion. <br />I Operation handle features white arrows showing basic <br />operation direction, for non-English-speaking persons. <br />I Braille text included In finger-hold area of operation <br />handle and across top of handle. <br />I Multiple hex- and key-lock models available. <br />o U.S. patent-pending hex-lock needs only a quarter-turn <br />to lock/unlock. <br />I Station can be opened for Inspection and maintenance <br />without initiating an alarm. <br />I Product 10 label viewable by simply opening the cover; <br />label is made of a durable long-life material. <br />I The words "NORMAL" and "ACTIVATED" are molded into <br />the plastic adjacent to the alarm switch (located inside). <br />I Four-position terminal strip molded into backplate. <br />o Terminal strip includes Phillips combination-head cap- <br />tive 8/32 screws for easy connection to Initiating Device <br />Circuit (IDC). <br />o Terminal screws backed-out at factory and shipped ready <br />to accept field wiring (up to 12 AWG/3.1 mm2). <br />I Terminal numbers are molded into the backplate, elimi- <br />nating the need for labels. <br /> <br />c@us <br /> <br />LISTED <br />S711 <br /> <br /> <br />California <br />State Fire <br />Marshal <br />7150-0075:184 <br /> <br /><19 <br />APPROVED <br /> <br />MEA <br /> <br />67-02-E <br /> <br /> <br />~ <br />i <br /> <br />o Switch contacts are normally open. <br />. Can be surface (with S8-1/0 or S8-10) or semi-flush <br />mounted. Semi-flush mount to a standard single-gang, <br />double-gang, or 4" (10.16 cm) square electrical box. <br />I Backplate is large enough to overlap a single-gang <br />backbox cutout by up to 1/2" (1.27 em). <br />. Optional trim ring (BG-TR). <br />I Spanish version (FUEGO) available (BG-12LSP). <br />I Designed to replace the Fire"Ute legacy BG-10 Series. <br />I Models packaged In attractive, clear plastic (PVC), <br />clamshell-style. point-of-purchase packages, Packag- <br />ing includes a cutaway dust/paint cover in shape of pull <br />station. <br /> <br />FlreoUteQll Alarma, System Senaorfl). and SpectrAlertll!) are <br />registered trademarks of Honeywell International Inc. lEXAN<J Is <br />a registered trademark of GE Plastics, a subsidiary of General <br />Electric Company. <br /> <br />This document is not intended to be used for installation purposes. We try 10 keep our product <br />information up.to-date and accurate. We cannot cover all specific applications or anticipate all <br />requirements. All specifications are subject to change without notice. <br />For more information, contact Fire-Lite Alarms, One Fire-Ute Place, Northford, Connecticu' 06472. <br />Phone: (BOO) 627-3473, Toll-Free FAX: (877) 699-4105. <br /> <br />ISO 9001 <br /> <br />CI::RTII=IIED <br /> <br />Ef8I1I1IIS I MWAmIM: <br />QUALITY SYSTEMS <br /> <br />DF-52004.06I10/05 - Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.