My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
AMERIKOOLER ARCHITECTURAL SPECS.07-7038
Zephyrhills
>
Building Department
>
Permits
>
Product Specification Books
>
AMERIKOOLER ARCHITECTURAL SPECS.07-7038
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2008 8:36:33 AM
Creation date
1/18/2008 10:36:41 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-7038
Building Department - Name
KOB PROPERTIES LLC
Address
7825 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Zephyrhills Fire Rescue <br />6907 Dairy Road, Zephyrhills, FL 33542 <br /> <br />Fire Marshal <br />Kerry Barnett <br /> <br />Bus (813) 780-0041 <br />Fax (813) 780-0044 <br /> <br />September 24, 2007 <br /> <br />Plan Review Comments <br /> <br />I have reviewed and approved the plans for an interior remodel located at 7825 Gall Blvd. <br />under the following conditions. My comments have been placed below. Please contact <br />me if you have any questions with regards to my comments. <br /> <br />I. Separate permit and plans shall be submitted by certified contactors for approval <br />for the commercial exhaust hood with duct, commercial hood suppression system, <br />and natural gas installation. <br />2. Sprinkler system shall include drops into freezer. System shall also be recertified <br />that it meets compliance to new layout. Separate permit and plans shall be <br />submitted by certified contractor for approval. <br />3. Certified fire extinguishers shall be installed in compliance with NFPA 10. <br />4. Knox box required per Florida Fire Prevention Code. Obtain application from <br />Zephyrhills Fire Rescue - 6907 Dairy Rd. <br />5. Seating in seating area shall be figured by 15 sq ft per person of use able space. It <br />will be rechecked by ARl. <br />6. Install hardwire smoke detector with battery backup in dry storage room and in <br />hallway outside restrooms. <br />7. Add emergency light in restrooms and change out rear exit light to combination <br />exit/emergency light. <br />8. Install CO detector in kitchen area due to use of gas. <br /> <br />Inspections required: <br /> <br />1. Building final. <br />2. Additional inspections are required through other contractors performing work <br />and will be listed on their plan review comment sheets. <br />
The URL can be used to link to this page
Your browser does not support the video tag.