Laserfiche WebLink
<br />I I <br />OHM 6G OA-2004R EnergyGauge@ 4.5 <br /> , Code Compliance Checklist <br />f ~esidential Whole Building Performance Method A - Details <br />, ADDR ss: PALM ISLAND(LOT#11 ,BL#3), ZEPHYRHILLS, FL, PERMIT #: , <br />6A-21 IN IL TRA TION REDUCTION COMPLIANCE CHECKLIST <br />COM PONE NTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Wi dows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/sQ.ft. window area; .5 cfmIsQ.ft. door area. <br />Exterior & ) djacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> I penetrations; between wall panels & toplbottom plates; between walls and floor. <br /> i <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from and is sealed to, the foundation to the too olate. <br />Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the oerimeter, oenetrations and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> I soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> i <br /> , attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> , installed that is sealed at the perimeter, at oenetrations and seams. <br />Recessed Lthting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br /> , conditioned soace tested. <br />Multi-story H buses 606.1.ABC.1.2.5 Air barrier on oerimeter of floor cavity between floors. <br />Additional In Itration reqts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combustion air. <br />6A-22 011 -IER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br />COMPONE~ TS SECTION REQUIREMENTS CHECK <br />Water Heate s 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir <br /> breaker (electric) or cutoff (gas) must be orovided. Extemal or built-in heat trao reQuired. <br />Swimming PI ~Is & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br /> must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br /> efficiency of 78%. <br />Shower head 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. <br />Air Distributi~ n Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br /> attached, sealed, insulated, and installed in accordance with the criteria of Section 610. <br /> Ducts in unconditioned attics: R-6 min. insulation. <br />HV AC Contr~ s 607.1 Seoarate readilv accessible manual or automatic thermostat for each svstem. <br />Insulation 604.1, 602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br /> Common ceiling & floors R-11. <br /> <br />F <br /> <br />EnergyGauge DCA Form 600A-2004R <br /> <br />EnergyGauge@/FlaRES'2004 FLRCSB v4.5 <br />