Laserfiche WebLink
<br />\..J-,::I.:.) - ,,~-..r\oJ_...... ..- "",,~ <br />Jacobson Window Company -3:. <br /> <br />r~ ~ <br />NGrL-210-2199-4 <br /> <br />OPTIONAL PERFORMANCE <br /> <br />Par. No. <br />4.3 <br /> <br />Title of Test Be Method <br />Water Resistance - ASTM E 547 <br />5.0 gphlft.2 <br />WTP= 8.25 psf <br /> <br />Measured <br /> <br />Allowed <br /> <br />No EJitry <br /> <br />No Entry <br /> <br />4.4.2 <br /> <br />Uniform Load Structural - ASTM E330 <br />52.5 psf Exterior <br />52.5 psf Interior <br /> <br />0.306" <br />0.312" <br /> <br />0.320" <br />0.320" <br /> <br />TEST COMPLETED: OS/28/99 <br /> <br />- <br /> <br />The tested specimen meets the performance criteria level of (SGD-LC35) * (145 x SOJ-of the <br />AAMA1NWWDA 101/T.R2-97 specification. <br /> <br />Detailed drawings were available for laboratory records and comparison to the test specimen at <br />the time of this report. A copy of this report along with representative sections of the test <br />specimen will be retained by NCfL for a period of four (4) years. The results obtained apply only <br />to the specimen tested. No conclusions of any kind regarding the adequacy or inadequacy of the <br />glass in the test specimen may be drawn from this test. This report does not constitute <br />certification of the product which may only be granted by a certification program validator. <br /> <br />NATIONALGERTIFIED TESTING <br />LARORATORIF-S. INC. <br /> <br />((Y)~ ~~@) <br /> <br />MICHAEL E. LANE <br />Division Manager <br /> <br />/ <br />vJ- <br /> <br /> <br />