Laserfiche WebLink
<br />Jacobson +Vindow Company <br /> <br />-, ~ - - ...... <br /> <br />, I - <br />NCTL-210-2741-1 <br /> <br />-3- <br /> <br />OPTIONAL PERFORMANCE GRADES <br /> <br />par. No. <br />4.3 <br /> <br />Title of Test & Method <br />Water Resistance - ASTM E547 <br />5.0 gph/ftZ <br />WTP== 7.5 psf <br /> <br />Measured <br /> <br />Allowed <br /> <br />No Leakage <br /> <br />No Leakage <br /> <br />4.4.2 <br /> <br />Uniform Load structural - ASTM E330 <br />60.0 psf Exterior <br />60.0 psf f.nterior <br /> <br />0.025" <br />0.050" <br /> <br />0.204" <br />'0.204" <br /> <br />TEST COMPLETED 11/08/01 <br /> <br />T'he tested specimen meets (or exceeds) the performance levels specirred in Table 2.1 of <br />ANSI / AAMA/ NWWDA 101/ 1.S.2-97 for air infiltration. The listed results were secured by <br />using the designated test methods and indicate compliance with the performance requirements <br />ol the referenced specification paragraphs for the (H-R40) (.53x76) product designation. <br /> <br />Detailed drawings were available for laboratory records and comparison to the test specim,en <br />a,t the time of this report. A copy of this report along with representative sections of the test <br />specimen will be retained by NCTL ['Or a period of four (4) years: The results obtained apply <br />only to the specimen tested. No conclusions of any kind regarding the adequacy or inadequacy <br />ol the glass in the test specimen may be drawn from this test. This report does not constitute <br />certification of the product which may only be granted by a certification program validator. <br /> <br />NAT'ONAL CERTIFIED TESTING LABORATORIES <br /> <br />D~~OS-- <br /> <br />Laboratory Manager <br /> <br />II /!J <br />~u ~1(fIO~ <br />