My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
PRODUCT TECHNOLOGY CORP.
Zephyrhills
>
Building Department
>
Permits
>
Product Specification Books
>
PRODUCT TECHNOLOGY CORP.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2008 2:59:52 PM
Creation date
2/13/2008 2:52:06 PM
Metadata
Fields
Template:
Building Department
Company Name
JACOBSON WINDOW COMPANY
Building Department - Doc Type
PSB
Address
1707 W NORTH A STREET
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
25
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Jrac,obson 'Window Company <br /> <br />-3- <br /> <br />Co Lo){;l~ <br /> <br />I .... <br />NCTL-210-2741-2 <br /> <br />OPTIONAL PERFORMANCE GRADES <br /> <br />.- <br /> <br />Par. No. <br />4.3 * <br /> <br />Title of Test & 1\1ethod <br />Water Resist.ance - ASTM E547 <br />5.0 gphlftZ <br />WTP= 7.5 psf <br /> <br />Measured <br /> <br />Allowed <br /> <br />No Leakage <br /> <br />No Leakage <br /> <br />4.4.2 <br /> <br />Uniform LoOd structural -, ASTM E330 <br />52.5 psf Exterior <br /> <br />A 0.030" <br />B. 0.040" <br /> <br />0.204" <br />0.199" <br /> <br />52.5 psf Interior <br /> <br />A:. 0.050" <br />B.0.090'" <br /> <br />0.204" <br />0.199" <br /> <br />Note: A Mid-span of meeting rail B. Mid-span of Iwrizontal muntin of active sash <br /> <br />TEST COMPLETED 01128/02 <br /> <br />~rhe t.ested specimen I1tee/.s (or e.'U:eeds) the performance levels speci{ted in Table 2.1 of <br />ANSI 1 AAJ.1AI NWWDA 101/ 1.S.2-97 for air infiltration. The listed results were secured by <br />lL..<;ing the designated test methods and indicate compliance with the perform.ance. requirent'ents <br />of tlte referenced specification paragraphs for the H-R35 (53x76) product designation. <br /> <br />Detailed drawings were available for laboratory records and comparison to the test specim,en <br />at the time of this report. A copy of this report along with representative sections of the test <br />$,pecimen will be retained by NCTL for a period of four (4) years. The results obtained apply <br />only to the specimen tested. No conclusions of any kind regarding the adequacy or inadequacy <br />of the glass in the test specimen may be drawn {rom this test. 'This report does not constitute <br />certification of the product which may only be granted by a certification program validator. <br /> <br />NATIONAL CERTIFIED TESTING LABORATORIES <br /> <br />Q <br />.J <br />LVlIEL CONYERS <br />La.boratory Manager <br /> <br /> <br />nvlf <br />'V~(p{11lOV <br />
The URL can be used to link to this page
Your browser does not support the video tag.