Laserfiche WebLink
<br /> <br />RESPONSIBiliTY 0:::: <br /> 0 <br /> f- <br /> er::: 0 <br />SCHEDULE w <( <br />C) er::: <br /><( f- <br /> Z Z <br /> <( 0 <br /> PLEASE USE THIS FOR ITEMS :2 0 <br /> APPLICABLE TO THIS PROJECT f- ------.J <br /> ONL Y. RESPONSIBILITIES MAY 0 <( <br /> VARY PER PROJECT. W er::: <br /> --:J W <br /> 0 z <br /> ITEM er::: w <br /> D- C) <br />PHARMACY GRILLE <br />LIGHT FIXTURES . <br />CARPET . <br />LAMPS . <br />DUMPSTER . <br />CONVEYOR <br />EMS (LIGHTING PANEL ONLY) <br />AUTOMA TIC DOORS <br />WALK-IN COOLERS <br />CUSTOM MILLWORK . <br />PRE -F AB GRAPHICS . <br />EAS <br />ALARM SYSTEMS . <br />TELEPHONES . <br />UN I WE B . <br />EMS (CPC ONLY) <br />SCANMASTER <br />EDIT LIST . <br />SIGNS . <br />COOLERS (NOT WALKIN) . <br />SAFE <br /> <br />LIS <br />T-1 <br /> <br />OF DRA WINGS <br />TITLE SHEET <br /> <br />FIXTURES <br />F -1 MERCHANDISE PLAN <br /> <br />ARCHITECTURAL <br />D-1 DEMOLITION PLAN <br />A-1 FLOOR PLAN <br />A-2 SCHEDULES &1 DETAILS <br />A -3 INTERIOR ELEV A TIONS <br />A-4 FLOOR FINISH 'PLAN <br />A -5 OFFICE PLANS AND DET AILS <br /> <br />PLUMBING <br />P-1 PLUMBING PLAN <br /> <br />ELECTRICAL <br />E-1 ELECTRICAL LIGHTING PLAN <br />E-2 ELECTRICAL ROWER PLAN <br /> <br />i <br /> <br />E-3 ELECTRICAL DETAILS <br /> <br />PROJECT INFORMATION <br /> <br />BUILDING INFORMATION/CODE ANALYSIS <br /> <br />PROPOSED ALTERATIONS/RENOVATIONS <br /> <br /> <br />EXISTING BUILDING <br /> <br />TENANT: <br />ECKERD <br />P.O. BOX 4689 <br />CLEARWATER, FL. 33777 <br />(727)395-6948 <br /> <br />ARCHITECT: <br /> <br />LARSON DESIGN GROUP, INC. <br />1000 COMMERCE PARK DRIVE <br />PO BOX 487 <br />WILLlAMSPORT, PA 17701 <br />A TTN: ROBERT J. GEHR <br />(570) 323-6603 <br /> <br />PRESENT OCCUPANn <br />TYPE OF BUSINESS: <br />USE GROUP/MIXED USE: <br />CONSTRUCTION TYPE: <br />HEIGHT/NUMBER OF STORIES: <br />HIGH RISE: <br />COVERED MALL: <br />FIRE PROTECTION: <br />FLOOR AREA OF TENANT SPACE <br />OR AREA OF RENOVATION: <br /> <br />ECKERD PHARMACY <br />RETAIL/PHARMACY <br />MERCHANTILE <br />28 <br />ONE <br />N/A <br />N/A <br />RECEIVING AREA ONLY <br /> <br />STORE SET -UP MANAGER: <br />N/A <br /> <br />PLANNING MANAGER: <br />CHRISTINA SPROWS <br />(401) 765-1500 EXl 7814 <br /> <br />CONSULTANT: <br />N/A <br /> <br />10,908 SQ. FT. <br /> <br />UL DESIGN NUMBERS: <br />-DEMISING PARTITIONS: -- U905 <br />-CEILING: ----------- EXISTING <br />-COLUMNS: ---------- EXISTING <br /> <br />FLAME SPREAD DATA: <br />-MATERIAL FLAME <br />- CEI LI N G TI LES <br />-VINYL COMPOSITION <br />CARPET <br />PLASTIC LAMINATES <br />-LA TEX PAINTS <br />- VINYL WALLCOVERINGS <br /> <br />THE PROPOSED MODIFICATIONS TO THIS BUILDING SHALL BE IN COMPLIANCE WITH THE: <br />2001 FLORIDA BUILDING CODE <br /> <br />SPREAD(ASTM E-84) <br />0-25 <br />TILES <br /> <br />NOTE: VERIFY CURRENT CODE IN USE WITH AUTHORITY HAVING JURISDICTION. <br /> <br />0-30 <br />0-10 <br />0-25 <br /> <br />PROJECT SCOPE OF WORK <br /> <br />CHECKOUT: <br />-STRIP FINISH FROM EXISTING YCT. PREPARE TO RECEIVE NEW <br />CUSHION-BACKED CARPET. <br />-REMOYE ALL EXISTING WALL AND CEILING HUNG GRAPHICS. <br />-REMOVE EXISTING CHECKOUT IN ITS ENTIRETY, INCLUDING ASSOCIATED <br />MILLWORK. SAVE ALL UTILITIES FOR RELOCATION. <br />-REMOVE EXISTING "GREETING CARDS" HANGING LIGHTED SIGN. <br />-RELOCA TE EXISTING LIGHTS AND DIFFUSERS AS REQUIRED FOR <br />INSTALLATION OF NEW PARAWASH LIGHT FIXTURES AS SHOWN. <br /> <br />-PATCH AND PAINT EXISTING WALLS AS REQUIRED. <br />-INSTALL NEW/RELOCATE EXISTING UTILITIES AS REQUIRED. <br />- TRENCH AS REQUIRED TO INSTALL NEW/RELOCATE EXISTING UTILITIES. <br />REMOVE OLD UTILITY STUB AND PATCH FLOOR, IF REQUIRED. <br />-INSTALL NEW 20'-4" BAGW'ELL CHECKOUT COUNTER AND ALL ASSOCIATED <br />MILLWORK. INST ALL NEW/RELOCATE EXISTING ELECTRICAL AND DATA LINES <br />AS REQUIRED. <br />-INSTALL NEW CUSHION-BACKED CARPET AT CHECKOUT AS SHOWN. <br />-INSTALL NEW VINYL BASE. <br />-INSTALL NEW HANGING GRAPHICS PANELS. <br />-INSTALL NEW PARAWASH LIGHT FIXTURES AS SHOWN; CONNECT TO EXISTING CIRCUITS. <br />-INSTALL NEW GATE AS SHOWN. <br />-INSTALL NEW "GREETING CARD" HANGING NEON SIGN AS SHOWN. <br /> <br />PHOTO LAB: <br /> <br />-REMOVE ALL EXISTING WALL AND CEILING HUNG GRAPHICS. <br />-REMOVE EXISTING PHOTO LAB IN ITS ENTIRETY. SAVE FILM PROCESSOR AND ALL <br />UTILITIES FOR RELOCATION. <br />-REMOVE "1-HOUR PHOTO" HANGING LIGHTED SIGN, IF EXISTING. <br />-REMOVE EXISTING PLUMBING LINES AT EXISTING SINK. SAVE <br />FOR RELOCATION TO NEW PHOTO LAB SINK AS SHOY1N. <br />-REMOVE EXISTING WATER HEATER AND ELECTRICAL CIRCUIT. <br />SA VE FOR RELOCATION AS SHOWN. <br />-RELOCATE EXISTING LIGHTS AND DIFFUSERS AS REQUIRED FOR <br />INSTALLATION OF NEW PARAWASH LIGHT FIXTURES AS SHOWN. <br />-RELOCA TE EXISTING FILM PROCESSOR AND UTILITIES AS SHOWN. <br />-PATCH AND PAINT EXISTING WALLS AS REQUIRED. <br />-INSTALL NEW PHOTO LAB MILLWORK, COMPLETE, AS SHOWN. <br />-INSTALL NEW/RELOCATE EXISTING UTILITIES AS REQUIRED. <br />-INSTALL NEW POWER POLE(S) AS SHOWN. <br />-CLEAN AND POLISH EXISTING YCT. <br />-INSTALL NEW YINYL BASE AS REQUIRED. <br />-INSTALL NEW OUTLET FOR NEW "1-HOUR PHOTO" SIGN, IF NONE EXISTS. <br />-INSTALL NEW HANGING "1-HOUR PHOTO" SIGN AS SHOY1N. <br />-INSTALL NEW PARAWASH LIGHT FIXTURES AS SHOWN. <br />-INSTALL NEW HANGING PHOTO LAB GRAPHIC PANELS AS SHOWN. <br />-EXTEND EXISTING 1/2" COLD WATER LINE TO NEW SINK AS SHOWN. <br />-RELOCA TE EXISTING WATER HEATER AND ELECTRICAL CONNECTION TO <br />NEW PHOTOLAB AS SHOWN. <br />-INSTALL NEW SINK PUMP UNIT AT NEW SINK. EXTEND TO EXISTING <br />OVERHEAD SANITARY LINE, OR INSTALL NEW 1" OVERHEAD SANITARY LINE. <br />TIE INTO EXISTING SANITARY LINE AT EXISTING SINK BEING REMOVED. <br />ALL PIPING TO BE CONCEALED. <br />-INSTALL NEW PHOTO LAB SINK. CONNECT TO EXISTING PLUMBING <br />-INSTALL NEW FINISHED CHASEWA Y TO ABOVE EXJSTING CEILING. <br /> <br />MANAGERS OFFICE: <br /> <br />-STRIP FINISH FROM EXISTING YCT. PREPARE TO RECEIVE NEW CARPET. <br />-REMOVE EXISTING ALARM KEYPAD. SAVE FOR RELOCATION AS SHOWN. <br />-REMOVE EXISTING MANAGERS OFFICE IN ITS ENTIRETY. SAVE ALL <br />UTILITIES FOR RELOCATION. <br />-CONSTRUCT NEW OFFICE WALLS AS SHOY1N. <br />-INSTALL NEW DOOR, FRAME, AND HARDWARE. <br />-INSTALL NEW/RELOCATE EXISTING UTILITIES AS REQUIRED. <br />-INSTALL NEW UTILITY CHASE IN CORNER AS SHOWN. <br />-INSTALL NEW/RELOCATE EXISTING COUNTERS AND SHELVING AS <br />DIRECTED BY PROJECT MANAGER. <br />- APPL Y NEW WALL COVERING AS SHOWN. <br />-INSTALL NEW CARPET AS SHOWN. <br />-INSTALL NEW VINYL BASE. <br />-RELOCATE EXISTING ALARM KEYPAD AS SHOWN. <br />-RELOCATE EXISTING SAFE AS DIRECTED BY PROJECT MANAGER. <br />-RELOCATE EXISTING CCTV MONITORS AS DIRECTED BY PROJECT MANAGER. <br /> <br />RET AIL: <br /> <br />-REMOVE EXISTING END PANELS AND DUMMY BOXES. <br />-REMOVE EXISTING LIGHTED HEADERS. SAVE CIRCUITS FOR RELOCATION AS SHOWN. <br />-REMOVE ALL EXISTING WALL AND CEILING HUNG GRAPHICS. <br />-REMOVE ALL EXISTING BLUE BANDS, LETTERING, MIRRORS, ETC. <br />-REMOVE ALL EXISTING AISLE MARKERS. <br />-REMOVE EXISTING FRAGRANCE COUNTER IN ITS' ENTIRETY. PROPERLY TERMINATE <br />ALL ELECTRICAL AND DATA LINES AS REQUIRED. <br />-REMOVE ALL EXISTING POW'ER POLES AT EXISTING FIXTURES. PROPERLY TERMINATE <br />ALL ELECTRICAL AS REQUIRED. <br />-REMOVE EXISTING GREEN CANOPY AT VITAMIN DEPARTMENT FIXTURES. <br />-REMOVE FINISH ON EXISTING YCT. PREPARE TO RECEIVE NEW FLOOR FINISHES. <br />-REMOVE EXISTING VINYL BASE. PREPARE FOR NEW. <br />-REMOVE EXISTING COOLER/FREEZERS. PROPERLY CAP OFF EXISTING REFRIGERATION LINES. <br />-REMOVE EXISTING CART CORRAL. <br />-INSTALL NEW RETAIL CARPET TILES. <br /> <br />-INSTALL NEW BEAUTY CARPET AS SHOWN. <br />-CLEAN AND POLISH EXISTING YCT TO REMAIN EXPOSED AFTER CARPETING <br />AT EXISTING COOLER/FREEZER, LIFE AISLE, AND BEAUTY CONSULTATION CENTER LOCATIONS AS SHOWN. <br />-REPLACE ALL EXISTING BLUE yeT TILES, REMAINING EXPOSED AFTER CARPETTING, \'11TH RECLAIMED WHITE TILES. <br />-PATCH AND PAINT EXISTING RETAIL AREA WALLS, INCLUDING EXISTING <br />WALL COVERING, BLUE ACCENTS AND TRIM, AND ALL AREAS EXPOSED <br />AFTER F1XTURING. <br />-INSTALL NEW OUTLETS FOR NEW CLM/FLM COOLERS AS SHOWN. <br />-INSTALL NEW CLM/FLM COOLERS AS SHOWN. <br />-INSTALL NEW END PANELS AND DUMMY BOXES AS SHOWN. <br />-INSTALL NEW OUTLETS AT NEW COOlERS/FREEZERS AS SHOWN. <br />-INSTALL NEW COOLERS/FREEZERS AS SHOWN. <br />-INSTALL NEW SIDEWALL FIXTURE STRAPPING AS REQUIRED. <br />-INSTALL NEW 4" VINYL BASE AFTER FIXTURING. <br />-INSTALL NEW FRAGRANCE CALL BUTTON AS SHOWN. <br />-INSTALL NEW OUTLETS FOR LIGHTED HEADERS. <br />-INSTALL NEW LIGHTED FIXTURE HEADERS. <br />-INSTALL NEW HANGING GRAPHIC PANELS AS SHOWN. <br />-PAINT EXISTING BLUE ACT CEILING GRID WHITE, IF APPLICABLE. <br />-RELOCA TE EXISTING ALARM KEY PAD TO NEW S.O.A. AS SHOY1N. <br />-INSTALL NEW HANGING AISLE MARKERS AS SHOWN. <br />-INSTALL (3) NEW SEASONAL OUTLETS AS SHOWN. <br />-INST ALL NEW POWER POLES AT BEAUTY FIXTURES AS SHOY1N. <br />-INSTALL NEW OUTLETS FOR BEAUTY FIXTURES AS SHOWN. <br />-INSTALL NEW KICKPLATE OUTLETS ON SIDEWALLS AS SHOY1N. <br />-INSTALL NEW BEAUTY CONSULT A TlON CENTER AS SHOY1N. <br />-INSTALL NEW 2 X 4 LIGHT FIXTURE AT NEW BEAUTY ARCH AS SHOY1N. <br />-INSTALL NEW/~ELOCATE EXISTING GREETING CARD AISLE MARKERS AS REO'D. <br />-INSTALL NEW PRICE CHECKERS AS SHOY1N. <br /> <br />RECEIVING AREA: <br /> <br />-REMOYE EXISTING PALLET RACKING AND BULK SHELVING. SAVE FOR <br />RELOCATION AS SHOWN. <br />-INSTALL NEW/RELOCATE EXISTING PALLET RACKING AND OS SHELVING AS SHOWN. <br /> <br />GENERAL: <br />-REPLACE ALL BURNED OUT LAMPS AND BALLASTS. <br />-REMOVE ALL EXISTING VINYL BASE. PREPARE FOR NEW. <br />-REPLACE ALL STAINED OR DAMAGED CEILING TILES. <br />-CLEAN ALL HVAC DIFFUSERS. <br />-REPAIR OR REPLACE ALL DAMAGED OR INOPERABLE EXISTING EXIT SIGNS AND <br />EMERGENCY LIGHTING, AS REQUIRED. <br />-RELOCA TE ALARM SENSORS, CONTROLS, SECURITY CAMERAS, ETC., AS <br />REQUIRED/DIRECTED BY PROJECT MANAGER. <br />-REPAIR OR REPLACE ALL DAMAGED SPRINKLER ESCUTCHEONS, IF APPLICABLE. <br />-CLEAN ALL EXISTING STOREFRONT GLASS AND FRAMING. <br /> <br />ECKERD PHARMACY <br />RETAIL/PHARMACY <br />MERCHANTlLE <br />28 <br />ONE <br />N/A <br />N/A <br />RECEIVING AREA ONLY <br /> <br />DESI <br />GRG <br /> <br /> <br />8,898 SQ. FT. <br /> <br />CARPET: ASTM E-648 RADIANT <br />-PANEL TEST EXCEEDS------.87 <br />WA TTS PER CFM <br />-PASSES DOC-F-1-70 <br />-NBS SMOKE DENSITY <br />LESS THAN------------279 <br /> <br />/' <br /> <br /> <br />K\~\I <br /> <br />AOR: ROBERT J. GEHR, A.I.A., NCARB <br />STA TE OF FLORIDA SEAL #AR0092168 <br />LARSON DESIGN GROUP, INC. <br />1000 COMMERCE PARK DR. <br />SUITE 201 <br />WILLlAMSPORT, PA 17701 <br />TEL (570) 323-6603 <br />FAX (570) 323-9902 <br /> <br />CRITICAL RADIANT FLUX(ASTM E-648) <br />0.55 WATTS/CM2 OR MORE <br /> <br />CONSUL TANT: <br /> <br />Office <br />Copy <br /> <br />Plans, maps, specifications, studies, <br />and reports not containinq a red <br />ink seal imprint accompanied by an <br />original signature by the licensed <br />r;>rofessional may have been <br />fraudulently altered and shall not <br />be considered an original copy. All <br />information should be disregarded <br />unless verified by the professional <br />whose signature appears above. <br />Copyright Protected 2003, <br />Larson Design Group, Inc. <br /> <br /> <br />pharmacy <br />STORE NUMBER: 0651 <br /> <br />37943 EILAND BLVD <br />ZEPHYRHILLS, FL 33541 <br />PROJECT TYPE: <br />00048 ACQUISITION( #0115) <br /> <br />Otfic~ <br />Copy <br /> <br /> <br />DAlE '4}!-'iJ~:~~.:c~~ 16W<1. :,) <br />eUI'_C'iNCi DE.PT APPROVE.D v --- (j <br /> <br />i:ll.~'1!:'l&~__-, . <br /> <br />ZEPHYRfirLLS <br />. FIRE DEPAHTMENT <br /> <br /> <br />.:... "~"~'h_,,__"_'_'J' ~;\.j;'il/\.L_ <br /> <br />'. ~[:\AlLL'\G cc:::':::s. fHJ:u1)A BU1LD!:',C, <br />CODE. SA TlO:'-lAL ELECTRIC eODE ~ ,,; <br />em OF ZEPHYRHllLS ORDINA'\CES <br /> <br />J'Jz/1 <br /> <br />{)ffi c~ <br />(;opy <br /> <br />PHARMACY AND WAITING AREA: <br /> <br />-REMOVE EXISTING CANOPY AND STRIP LIGHTS AT FRONT OF PHARMACY YALANCE; PROPERLY <br />TERMINATE EXISTING ELECTRICAL WIRING AS REQUIRED. <br />-REMOVE ALL EXISTING VALANCE AND CEILING HUNG GRAPHICS. <br />-REMOVE EXISTING WALL COVERING BELOW THE CHAIR RAIL AT WAITNG AREA. PREPARE FOR NEW <br />-REMOVE EXISTING CHAIR RAIL AT WAITNG AREA. PREPARE FOR NEW. <br />-REMOVE EXISTING RED & BLUE BANDS AT FRONTS OF EXJSTING PHARMACY COUNTERS. <br />-PATCH AND PAINT EXISTING PHARMACY VALANCE. <br />-INSTALL NEW PHARMACY HANGING GRAPHIC PANELS AS SHOY1N. <br />-INSTALL NEW PARAWASH LIGHT FIXTURES AS SHOY1N. <br />-RELAMINATE EXISTING PHARMACY COUNTER FRONT FACES. <br />-INSTALL NEW OUTLET AT WAITING AREA FOR NEW CLM COOLER, IF NONE EXISTS. <br />-INSTALL NEW CLM COOLER NEAR WAITING AREA. <br />-INSTALL NEW CHAIR RAIL AT WAITING AREA AS SHOWN. <br />-PATCH AND PAINT EXISTING WALL AND/OR WALL COVERING ABOVE NEW CHAIR RAIL <br />AT WAITING AREA. <br />-INSTALL NEW LAMINATE BELOW NEW CHAIR RAIL AT WAITiNG AREA AS SHOWN. <br />-REUSE EXISTING WAITING SEATS AT WAITING AREA AS SHOWN. <br /> <br />REVISIONS: <br /> <br />Otlice <br />Copy <br /> <br />STORE SET-UP MANAGER: <br />LAYOUT COORD.: <br />PROJECT ARCHITECT: <br />PLANNING MGR: <br /> <br />RJG <br />CS <br />SAB AJM ABB RLW <br /> <br />DRAWING BY: <br />DRAWING SCALE <br />TITLE: <br /> <br />AS SHOWN <br /> <br />TITLE SHEET <br /> <br />SHEET NUMBER: <br /> <br />T-1 <br /> <br />OUTLINE : - <br />REVIEW: <br />FINAL: 9/1/04 <br />REVISION <br /> <br />I PERMIT] <br />