<br />
<br />RESPONSIBiliTY 0::::
<br /> 0
<br /> f-
<br /> er::: 0
<br />SCHEDULE w <(
<br />C) er:::
<br /><( f-
<br /> Z Z
<br /> <( 0
<br /> PLEASE USE THIS FOR ITEMS :2 0
<br /> APPLICABLE TO THIS PROJECT f- ------.J
<br /> ONL Y. RESPONSIBILITIES MAY 0 <(
<br /> VARY PER PROJECT. W er:::
<br /> --:J W
<br /> 0 z
<br /> ITEM er::: w
<br /> D- C)
<br />PHARMACY GRILLE
<br />LIGHT FIXTURES .
<br />CARPET .
<br />LAMPS .
<br />DUMPSTER .
<br />CONVEYOR
<br />EMS (LIGHTING PANEL ONLY)
<br />AUTOMA TIC DOORS
<br />WALK-IN COOLERS
<br />CUSTOM MILLWORK .
<br />PRE -F AB GRAPHICS .
<br />EAS
<br />ALARM SYSTEMS .
<br />TELEPHONES .
<br />UN I WE B .
<br />EMS (CPC ONLY)
<br />SCANMASTER
<br />EDIT LIST .
<br />SIGNS .
<br />COOLERS (NOT WALKIN) .
<br />SAFE
<br />
<br />LIS
<br />T-1
<br />
<br />OF DRA WINGS
<br />TITLE SHEET
<br />
<br />FIXTURES
<br />F -1 MERCHANDISE PLAN
<br />
<br />ARCHITECTURAL
<br />D-1 DEMOLITION PLAN
<br />A-1 FLOOR PLAN
<br />A-2 SCHEDULES &1 DETAILS
<br />A -3 INTERIOR ELEV A TIONS
<br />A-4 FLOOR FINISH 'PLAN
<br />A -5 OFFICE PLANS AND DET AILS
<br />
<br />PLUMBING
<br />P-1 PLUMBING PLAN
<br />
<br />ELECTRICAL
<br />E-1 ELECTRICAL LIGHTING PLAN
<br />E-2 ELECTRICAL ROWER PLAN
<br />
<br />i
<br />
<br />E-3 ELECTRICAL DETAILS
<br />
<br />PROJECT INFORMATION
<br />
<br />BUILDING INFORMATION/CODE ANALYSIS
<br />
<br />PROPOSED ALTERATIONS/RENOVATIONS
<br />
<br />
<br />EXISTING BUILDING
<br />
<br />TENANT:
<br />ECKERD
<br />P.O. BOX 4689
<br />CLEARWATER, FL. 33777
<br />(727)395-6948
<br />
<br />ARCHITECT:
<br />
<br />LARSON DESIGN GROUP, INC.
<br />1000 COMMERCE PARK DRIVE
<br />PO BOX 487
<br />WILLlAMSPORT, PA 17701
<br />A TTN: ROBERT J. GEHR
<br />(570) 323-6603
<br />
<br />PRESENT OCCUPANn
<br />TYPE OF BUSINESS:
<br />USE GROUP/MIXED USE:
<br />CONSTRUCTION TYPE:
<br />HEIGHT/NUMBER OF STORIES:
<br />HIGH RISE:
<br />COVERED MALL:
<br />FIRE PROTECTION:
<br />FLOOR AREA OF TENANT SPACE
<br />OR AREA OF RENOVATION:
<br />
<br />ECKERD PHARMACY
<br />RETAIL/PHARMACY
<br />MERCHANTILE
<br />28
<br />ONE
<br />N/A
<br />N/A
<br />RECEIVING AREA ONLY
<br />
<br />STORE SET -UP MANAGER:
<br />N/A
<br />
<br />PLANNING MANAGER:
<br />CHRISTINA SPROWS
<br />(401) 765-1500 EXl 7814
<br />
<br />CONSULTANT:
<br />N/A
<br />
<br />10,908 SQ. FT.
<br />
<br />UL DESIGN NUMBERS:
<br />-DEMISING PARTITIONS: -- U905
<br />-CEILING: ----------- EXISTING
<br />-COLUMNS: ---------- EXISTING
<br />
<br />FLAME SPREAD DATA:
<br />-MATERIAL FLAME
<br />- CEI LI N G TI LES
<br />-VINYL COMPOSITION
<br />CARPET
<br />PLASTIC LAMINATES
<br />-LA TEX PAINTS
<br />- VINYL WALLCOVERINGS
<br />
<br />THE PROPOSED MODIFICATIONS TO THIS BUILDING SHALL BE IN COMPLIANCE WITH THE:
<br />2001 FLORIDA BUILDING CODE
<br />
<br />SPREAD(ASTM E-84)
<br />0-25
<br />TILES
<br />
<br />NOTE: VERIFY CURRENT CODE IN USE WITH AUTHORITY HAVING JURISDICTION.
<br />
<br />0-30
<br />0-10
<br />0-25
<br />
<br />PROJECT SCOPE OF WORK
<br />
<br />CHECKOUT:
<br />-STRIP FINISH FROM EXISTING YCT. PREPARE TO RECEIVE NEW
<br />CUSHION-BACKED CARPET.
<br />-REMOYE ALL EXISTING WALL AND CEILING HUNG GRAPHICS.
<br />-REMOVE EXISTING CHECKOUT IN ITS ENTIRETY, INCLUDING ASSOCIATED
<br />MILLWORK. SAVE ALL UTILITIES FOR RELOCATION.
<br />-REMOVE EXISTING "GREETING CARDS" HANGING LIGHTED SIGN.
<br />-RELOCA TE EXISTING LIGHTS AND DIFFUSERS AS REQUIRED FOR
<br />INSTALLATION OF NEW PARAWASH LIGHT FIXTURES AS SHOWN.
<br />
<br />-PATCH AND PAINT EXISTING WALLS AS REQUIRED.
<br />-INSTALL NEW/RELOCATE EXISTING UTILITIES AS REQUIRED.
<br />- TRENCH AS REQUIRED TO INSTALL NEW/RELOCATE EXISTING UTILITIES.
<br />REMOVE OLD UTILITY STUB AND PATCH FLOOR, IF REQUIRED.
<br />-INSTALL NEW 20'-4" BAGW'ELL CHECKOUT COUNTER AND ALL ASSOCIATED
<br />MILLWORK. INST ALL NEW/RELOCATE EXISTING ELECTRICAL AND DATA LINES
<br />AS REQUIRED.
<br />-INSTALL NEW CUSHION-BACKED CARPET AT CHECKOUT AS SHOWN.
<br />-INSTALL NEW VINYL BASE.
<br />-INSTALL NEW HANGING GRAPHICS PANELS.
<br />-INSTALL NEW PARAWASH LIGHT FIXTURES AS SHOWN; CONNECT TO EXISTING CIRCUITS.
<br />-INSTALL NEW GATE AS SHOWN.
<br />-INSTALL NEW "GREETING CARD" HANGING NEON SIGN AS SHOWN.
<br />
<br />PHOTO LAB:
<br />
<br />-REMOVE ALL EXISTING WALL AND CEILING HUNG GRAPHICS.
<br />-REMOVE EXISTING PHOTO LAB IN ITS ENTIRETY. SAVE FILM PROCESSOR AND ALL
<br />UTILITIES FOR RELOCATION.
<br />-REMOVE "1-HOUR PHOTO" HANGING LIGHTED SIGN, IF EXISTING.
<br />-REMOVE EXISTING PLUMBING LINES AT EXISTING SINK. SAVE
<br />FOR RELOCATION TO NEW PHOTO LAB SINK AS SHOY1N.
<br />-REMOVE EXISTING WATER HEATER AND ELECTRICAL CIRCUIT.
<br />SA VE FOR RELOCATION AS SHOWN.
<br />-RELOCATE EXISTING LIGHTS AND DIFFUSERS AS REQUIRED FOR
<br />INSTALLATION OF NEW PARAWASH LIGHT FIXTURES AS SHOWN.
<br />-RELOCA TE EXISTING FILM PROCESSOR AND UTILITIES AS SHOWN.
<br />-PATCH AND PAINT EXISTING WALLS AS REQUIRED.
<br />-INSTALL NEW PHOTO LAB MILLWORK, COMPLETE, AS SHOWN.
<br />-INSTALL NEW/RELOCATE EXISTING UTILITIES AS REQUIRED.
<br />-INSTALL NEW POWER POLE(S) AS SHOWN.
<br />-CLEAN AND POLISH EXISTING YCT.
<br />-INSTALL NEW YINYL BASE AS REQUIRED.
<br />-INSTALL NEW OUTLET FOR NEW "1-HOUR PHOTO" SIGN, IF NONE EXISTS.
<br />-INSTALL NEW HANGING "1-HOUR PHOTO" SIGN AS SHOY1N.
<br />-INSTALL NEW PARAWASH LIGHT FIXTURES AS SHOWN.
<br />-INSTALL NEW HANGING PHOTO LAB GRAPHIC PANELS AS SHOWN.
<br />-EXTEND EXISTING 1/2" COLD WATER LINE TO NEW SINK AS SHOWN.
<br />-RELOCA TE EXISTING WATER HEATER AND ELECTRICAL CONNECTION TO
<br />NEW PHOTOLAB AS SHOWN.
<br />-INSTALL NEW SINK PUMP UNIT AT NEW SINK. EXTEND TO EXISTING
<br />OVERHEAD SANITARY LINE, OR INSTALL NEW 1" OVERHEAD SANITARY LINE.
<br />TIE INTO EXISTING SANITARY LINE AT EXISTING SINK BEING REMOVED.
<br />ALL PIPING TO BE CONCEALED.
<br />-INSTALL NEW PHOTO LAB SINK. CONNECT TO EXISTING PLUMBING
<br />-INSTALL NEW FINISHED CHASEWA Y TO ABOVE EXJSTING CEILING.
<br />
<br />MANAGERS OFFICE:
<br />
<br />-STRIP FINISH FROM EXISTING YCT. PREPARE TO RECEIVE NEW CARPET.
<br />-REMOVE EXISTING ALARM KEYPAD. SAVE FOR RELOCATION AS SHOWN.
<br />-REMOVE EXISTING MANAGERS OFFICE IN ITS ENTIRETY. SAVE ALL
<br />UTILITIES FOR RELOCATION.
<br />-CONSTRUCT NEW OFFICE WALLS AS SHOY1N.
<br />-INSTALL NEW DOOR, FRAME, AND HARDWARE.
<br />-INSTALL NEW/RELOCATE EXISTING UTILITIES AS REQUIRED.
<br />-INSTALL NEW UTILITY CHASE IN CORNER AS SHOWN.
<br />-INSTALL NEW/RELOCATE EXISTING COUNTERS AND SHELVING AS
<br />DIRECTED BY PROJECT MANAGER.
<br />- APPL Y NEW WALL COVERING AS SHOWN.
<br />-INSTALL NEW CARPET AS SHOWN.
<br />-INSTALL NEW VINYL BASE.
<br />-RELOCATE EXISTING ALARM KEYPAD AS SHOWN.
<br />-RELOCATE EXISTING SAFE AS DIRECTED BY PROJECT MANAGER.
<br />-RELOCATE EXISTING CCTV MONITORS AS DIRECTED BY PROJECT MANAGER.
<br />
<br />RET AIL:
<br />
<br />-REMOVE EXISTING END PANELS AND DUMMY BOXES.
<br />-REMOVE EXISTING LIGHTED HEADERS. SAVE CIRCUITS FOR RELOCATION AS SHOWN.
<br />-REMOVE ALL EXISTING WALL AND CEILING HUNG GRAPHICS.
<br />-REMOVE ALL EXISTING BLUE BANDS, LETTERING, MIRRORS, ETC.
<br />-REMOVE ALL EXISTING AISLE MARKERS.
<br />-REMOVE EXISTING FRAGRANCE COUNTER IN ITS' ENTIRETY. PROPERLY TERMINATE
<br />ALL ELECTRICAL AND DATA LINES AS REQUIRED.
<br />-REMOVE ALL EXISTING POW'ER POLES AT EXISTING FIXTURES. PROPERLY TERMINATE
<br />ALL ELECTRICAL AS REQUIRED.
<br />-REMOVE EXISTING GREEN CANOPY AT VITAMIN DEPARTMENT FIXTURES.
<br />-REMOVE FINISH ON EXISTING YCT. PREPARE TO RECEIVE NEW FLOOR FINISHES.
<br />-REMOVE EXISTING VINYL BASE. PREPARE FOR NEW.
<br />-REMOVE EXISTING COOLER/FREEZERS. PROPERLY CAP OFF EXISTING REFRIGERATION LINES.
<br />-REMOVE EXISTING CART CORRAL.
<br />-INSTALL NEW RETAIL CARPET TILES.
<br />
<br />-INSTALL NEW BEAUTY CARPET AS SHOWN.
<br />-CLEAN AND POLISH EXISTING YCT TO REMAIN EXPOSED AFTER CARPETING
<br />AT EXISTING COOLER/FREEZER, LIFE AISLE, AND BEAUTY CONSULTATION CENTER LOCATIONS AS SHOWN.
<br />-REPLACE ALL EXISTING BLUE yeT TILES, REMAINING EXPOSED AFTER CARPETTING, \'11TH RECLAIMED WHITE TILES.
<br />-PATCH AND PAINT EXISTING RETAIL AREA WALLS, INCLUDING EXISTING
<br />WALL COVERING, BLUE ACCENTS AND TRIM, AND ALL AREAS EXPOSED
<br />AFTER F1XTURING.
<br />-INSTALL NEW OUTLETS FOR NEW CLM/FLM COOLERS AS SHOWN.
<br />-INSTALL NEW CLM/FLM COOLERS AS SHOWN.
<br />-INSTALL NEW END PANELS AND DUMMY BOXES AS SHOWN.
<br />-INSTALL NEW OUTLETS AT NEW COOlERS/FREEZERS AS SHOWN.
<br />-INSTALL NEW COOLERS/FREEZERS AS SHOWN.
<br />-INSTALL NEW SIDEWALL FIXTURE STRAPPING AS REQUIRED.
<br />-INSTALL NEW 4" VINYL BASE AFTER FIXTURING.
<br />-INSTALL NEW FRAGRANCE CALL BUTTON AS SHOWN.
<br />-INSTALL NEW OUTLETS FOR LIGHTED HEADERS.
<br />-INSTALL NEW LIGHTED FIXTURE HEADERS.
<br />-INSTALL NEW HANGING GRAPHIC PANELS AS SHOWN.
<br />-PAINT EXISTING BLUE ACT CEILING GRID WHITE, IF APPLICABLE.
<br />-RELOCA TE EXISTING ALARM KEY PAD TO NEW S.O.A. AS SHOY1N.
<br />-INSTALL NEW HANGING AISLE MARKERS AS SHOWN.
<br />-INSTALL (3) NEW SEASONAL OUTLETS AS SHOWN.
<br />-INST ALL NEW POWER POLES AT BEAUTY FIXTURES AS SHOY1N.
<br />-INSTALL NEW OUTLETS FOR BEAUTY FIXTURES AS SHOWN.
<br />-INSTALL NEW KICKPLATE OUTLETS ON SIDEWALLS AS SHOY1N.
<br />-INSTALL NEW BEAUTY CONSULT A TlON CENTER AS SHOY1N.
<br />-INSTALL NEW 2 X 4 LIGHT FIXTURE AT NEW BEAUTY ARCH AS SHOY1N.
<br />-INSTALL NEW/~ELOCATE EXISTING GREETING CARD AISLE MARKERS AS REO'D.
<br />-INSTALL NEW PRICE CHECKERS AS SHOY1N.
<br />
<br />RECEIVING AREA:
<br />
<br />-REMOYE EXISTING PALLET RACKING AND BULK SHELVING. SAVE FOR
<br />RELOCATION AS SHOWN.
<br />-INSTALL NEW/RELOCATE EXISTING PALLET RACKING AND OS SHELVING AS SHOWN.
<br />
<br />GENERAL:
<br />-REPLACE ALL BURNED OUT LAMPS AND BALLASTS.
<br />-REMOVE ALL EXISTING VINYL BASE. PREPARE FOR NEW.
<br />-REPLACE ALL STAINED OR DAMAGED CEILING TILES.
<br />-CLEAN ALL HVAC DIFFUSERS.
<br />-REPAIR OR REPLACE ALL DAMAGED OR INOPERABLE EXISTING EXIT SIGNS AND
<br />EMERGENCY LIGHTING, AS REQUIRED.
<br />-RELOCA TE ALARM SENSORS, CONTROLS, SECURITY CAMERAS, ETC., AS
<br />REQUIRED/DIRECTED BY PROJECT MANAGER.
<br />-REPAIR OR REPLACE ALL DAMAGED SPRINKLER ESCUTCHEONS, IF APPLICABLE.
<br />-CLEAN ALL EXISTING STOREFRONT GLASS AND FRAMING.
<br />
<br />ECKERD PHARMACY
<br />RETAIL/PHARMACY
<br />MERCHANTlLE
<br />28
<br />ONE
<br />N/A
<br />N/A
<br />RECEIVING AREA ONLY
<br />
<br />DESI
<br />GRG
<br />
<br />
<br />8,898 SQ. FT.
<br />
<br />CARPET: ASTM E-648 RADIANT
<br />-PANEL TEST EXCEEDS------.87
<br />WA TTS PER CFM
<br />-PASSES DOC-F-1-70
<br />-NBS SMOKE DENSITY
<br />LESS THAN------------279
<br />
<br />/'
<br />
<br />
<br />K\~\I
<br />
<br />AOR: ROBERT J. GEHR, A.I.A., NCARB
<br />STA TE OF FLORIDA SEAL #AR0092168
<br />LARSON DESIGN GROUP, INC.
<br />1000 COMMERCE PARK DR.
<br />SUITE 201
<br />WILLlAMSPORT, PA 17701
<br />TEL (570) 323-6603
<br />FAX (570) 323-9902
<br />
<br />CRITICAL RADIANT FLUX(ASTM E-648)
<br />0.55 WATTS/CM2 OR MORE
<br />
<br />CONSUL TANT:
<br />
<br />Office
<br />Copy
<br />
<br />Plans, maps, specifications, studies,
<br />and reports not containinq a red
<br />ink seal imprint accompanied by an
<br />original signature by the licensed
<br />r;>rofessional may have been
<br />fraudulently altered and shall not
<br />be considered an original copy. All
<br />information should be disregarded
<br />unless verified by the professional
<br />whose signature appears above.
<br />Copyright Protected 2003,
<br />Larson Design Group, Inc.
<br />
<br />
<br />pharmacy
<br />STORE NUMBER: 0651
<br />
<br />37943 EILAND BLVD
<br />ZEPHYRHILLS, FL 33541
<br />PROJECT TYPE:
<br />00048 ACQUISITION( #0115)
<br />
<br />Otfic~
<br />Copy
<br />
<br />
<br />DAlE '4}!-'iJ~:~~.:c~~ 16W<1. :,)
<br />eUI'_C'iNCi DE.PT APPROVE.D v --- (j
<br />
<br />i:ll.~'1!:'l&~__-, .
<br />
<br />ZEPHYRfirLLS
<br />. FIRE DEPAHTMENT
<br />
<br />
<br />.:... "~"~'h_,,__"_'_'J' ~;\.j;'il/\.L_
<br />
<br />'. ~[:\AlLL'\G cc:::':::s. fHJ:u1)A BU1LD!:',C,
<br />CODE. SA TlO:'-lAL ELECTRIC eODE ~ ,,;
<br />em OF ZEPHYRHllLS ORDINA'\CES
<br />
<br />J'Jz/1
<br />
<br />{)ffi c~
<br />(;opy
<br />
<br />PHARMACY AND WAITING AREA:
<br />
<br />-REMOVE EXISTING CANOPY AND STRIP LIGHTS AT FRONT OF PHARMACY YALANCE; PROPERLY
<br />TERMINATE EXISTING ELECTRICAL WIRING AS REQUIRED.
<br />-REMOVE ALL EXISTING VALANCE AND CEILING HUNG GRAPHICS.
<br />-REMOVE EXISTING WALL COVERING BELOW THE CHAIR RAIL AT WAITNG AREA. PREPARE FOR NEW
<br />-REMOVE EXISTING CHAIR RAIL AT WAITNG AREA. PREPARE FOR NEW.
<br />-REMOVE EXISTING RED & BLUE BANDS AT FRONTS OF EXJSTING PHARMACY COUNTERS.
<br />-PATCH AND PAINT EXISTING PHARMACY VALANCE.
<br />-INSTALL NEW PHARMACY HANGING GRAPHIC PANELS AS SHOY1N.
<br />-INSTALL NEW PARAWASH LIGHT FIXTURES AS SHOY1N.
<br />-RELAMINATE EXISTING PHARMACY COUNTER FRONT FACES.
<br />-INSTALL NEW OUTLET AT WAITING AREA FOR NEW CLM COOLER, IF NONE EXISTS.
<br />-INSTALL NEW CLM COOLER NEAR WAITING AREA.
<br />-INSTALL NEW CHAIR RAIL AT WAITING AREA AS SHOWN.
<br />-PATCH AND PAINT EXISTING WALL AND/OR WALL COVERING ABOVE NEW CHAIR RAIL
<br />AT WAITING AREA.
<br />-INSTALL NEW LAMINATE BELOW NEW CHAIR RAIL AT WAITiNG AREA AS SHOWN.
<br />-REUSE EXISTING WAITING SEATS AT WAITING AREA AS SHOWN.
<br />
<br />REVISIONS:
<br />
<br />Otlice
<br />Copy
<br />
<br />STORE SET-UP MANAGER:
<br />LAYOUT COORD.:
<br />PROJECT ARCHITECT:
<br />PLANNING MGR:
<br />
<br />RJG
<br />CS
<br />SAB AJM ABB RLW
<br />
<br />DRAWING BY:
<br />DRAWING SCALE
<br />TITLE:
<br />
<br />AS SHOWN
<br />
<br />TITLE SHEET
<br />
<br />SHEET NUMBER:
<br />
<br />T-1
<br />
<br />OUTLINE : -
<br />REVIEW:
<br />FINAL: 9/1/04
<br />REVISION
<br />
<br />I PERMIT]
<br />
|