Laserfiche WebLink
<br />REVISION BY <br /> <br />CONT. 16" WIDE x 20" DEEP <br />MONOLITHIC SLAB EDGE/FTG. <br />W/ (2) #5's CONT. LAP SPLICES <br />MIN, 25" & TIE W/ WIRE. <br />TYP. @ PERIMETER <br /> <br />. <br /> <br /> <br />. <br /> <br /> <br />TIE NEW FTG. REINF, STEEL <br />INTO EXIST. FTG, BY <br />DOWELING NEW (2) #5's <br />INTO EXIST. FTG, MIN, 7" <br />AND SET W/ EPOXY GROUT <br />(TYP. WHERE NEW FTG'S. <br />MEET EXiSTING FTG'S,) <br /> <br />18'-8" <br /> <br /> r- <br /> u <br /> w L{) <br /> r- I"- <br /> - ~ <br /> :r: CO <br /> I <br /> U to <br /> 0::: CO <br /> N <br />~ <( <br />(f) ~ <br />x I") <br />w <br /> ^ ~ <br /> :2 CO <br /> ~ <br /> . <br /> 0 I <br /> (f) 0... <br /> 0::: I") <br /> N <br /> W to <br /> :r: I") to <br /> 1")1"'-- <br /> I"'-- <br /> ..- <br /> 0::: ~<{ I <br /> 1")0 to <br /> W 1")_0Cl <br /> >- ..q-cr::~ <br /> NOt<) <br /> <( -.-Joo <br /> XlL.'-" <br /> :r: o ..~ <br /> r- m<{1-- <br /> 0...;3 <br /> . L "'- <br /> .O<{X <br /> :r: cLf-~ <br /> <br />111"111 <br />1111'111 <br />I <br />i <br />~. III <br />III: III <br />III~ III <br /> <br />. <br /> <br />"cxJ <br />I <br />a <br />..- <br /> <br />· It ~HICK CONC~L;;- WI - - - - - <br />I 6 x 6 10/10 W,W.F. OR RECESS SLAB 3/4" <br />FIBERMESH REINF, ON @ SLIDING GLASS <br />I 6 MIL. POL YETHELENE DOOR TRACK <br />VAPOR BARRIER ON <br />I CLEAN, WELL-COMPACTED <br />SAND FILL W/ SOIL POISON- <br />liNG (TYP,) MATCH EXIST. <br />LIVING AREA FINISH FLOOR <br />. L ELEVATION ~YP.) ~ <br /> <br />l 100 cfm <br />f 10x8 <br />I~,-~ 6w d'IO <br />,.__.C_"_._" . <br />TO EXIST, <br />MAIN TRUNK <br /> <br />3: <br />w <br />z <br /> <br />. <br /> <br /> <br /> <br />PREMANUFACTURED & <br />ENGINEERED WOOD ROOF <br />TRUSSES @ MAX. 24" o,c. <br />TYP. SECURE TO NEW MASONRY <br />WALLS w/ USP 'DTC' TRUSS <br />ANCHORS TYP, EA. END, EA. TRUSS <br />MATCH EXISTING OVERH~" TYP. <br />---,--1-'--1- <br /> <br />I .. <br /> <br />TIE NEW FTG. REINF. STEEL <br />INTO EXIST. FTG, BY <br />DOWELING NEW (2) #5's <br />INTO EXIST. FTG. MIN. 7" <br />AND SET W/ EPOXY GROUT <br />(TYP. WHERE NEW FTG'S, <br />MEET EXISTING FTG'S.) <br /> <br />8'-0" <br /> <br />#2 S,Y,P. CROSS-BRACING <br />BETWEEN TOP CHORD AND BETWEEN <br />USP 'MP4F' BOTTOM CHORDS AND BETWEEN TOP <br />PLA TE TIES CHORD EXTERIOR TRUSS TO BOTTOM <br />@ 24" o.c. CHORD FOURTH TRUSS TYPICAL <br />MAX_ \ @ 48" D.C. AS INDICATED <br /> <br /> <br />-,--tl----,-----i <br />I I -1 <br />J <br />I <br />1 <br />~ <br />I <br /> <br />MECHAN~CAL PLAN <br />SCALE 1/4" == l' - 0" <br /> <br />FOUNDA r~ON PLAN <br />SCALE 1/4" == l' - 0" <br /> <br /> <br /> <br />I <br />EXIST. TRUSS <br />---- <br />I TYP. AS INDICATED <br />I <br /> <br />CONC, GROUT FILLED <br />BLOCK CELLS AS IN- <br />DICA TED w/ (1) #5 <br />VERT. REINFORCING <br />CONT. FROM FTG. TO <br />TIE BM. LAP SPLICES <br />MIN. 25" & WIRE TIE. <br /> <br />5-0 S.G,D, <br />L-7 UNTEL <br /> <br /> <br /> <br />I <br />.-, .-... --, .._' ...- "... .... _.' ..- ...- .....- --,'- -.. . ....., <br />"- <br />"- <br /> <br />6'-0" <br /> <br />18'-8" <br /> <br />SECURE NEW MASONRY <br />WALL TO EXIST. PER <br />DETAIL ON SHEET S-7 <br /> <br />7'-8" <br /> <br />5'-0" <br /> <br /> <br />"- <br />"- <br />"- <br /> <br />I <br />~-- <br /> <br />L___L_i <br />I <br /> <br />w <br /><..? <br />o <br />0:: <br /> <br />WP <br />GFCl <br /> <br /> <br /> <br /> <br />t <br />o <br />I <br />N <br /> <br />. <br /> <br /> <br />EXIST. <br /> <br />"- <br />"- <br />"- <br /> <br />3: <br />w <br />z <br /> <br />c::::> <br /> <br />Z~ <br />O~ <br />~ 'N <br />~ ~ <br />~~ <br />~ ttl <br />~~ <br />~~ <br />..q <br />W ~ <br />U~ <br />Z <br />w <br />~ <br />~ <br />rn. <br />w ~ <br />~~ <br />Q> <br />~~ <br />~ Q> <br />O~ <br />U~ <br />rn.~ <br />~ <br />z:.... <br /> <br />/ <br /> <br />NEW <br />FAMILY ROOM <br />VERIFY FIN. FLOORING <br />ON CONC, SLAB/ <br />8' FLAT CLG. <br /> <br />"cxJ N <br />I I <br />a CD <br />..- <br /> <br />~~ <br />l);~ <br />~0Cl <br />a.~ <br /> <br /> <br /> <br />SECURE NEW MASONRY <br />WALL TO EXIST. PER <br />DETAIL ON SHEET S-7 <br /> <br />= <br />CD .- <br />I <br />N <br /> <br /> <br />l EXISTING RESIDENCE <br />TO REMAIN) <br /> <br />EXIST. RIDGE TO REMAIN <br /> <br />~ EXISllNG ROOF & <br />STRUCTURE TO REMAIN \ <br /> <br />8'-0" <br /> <br />ROOF FRAM~NG PLAN <br />sd LE 1/4" == l' -0" <br /> <br />ELEcrR~CAL FLOOR PLAN <br />SCALE 1/4" == l' - 0" <br /> <br />192 s.t. ADDIT10N TO LIVING AREA <br /> <br />FLOOR PLAN <br />SCALE 1/4" == l' - 0" <br /> <br />. <br /> <br />U <br />Z~ <br />f---4 <br />~ <br />to <br />" C'J <br />lflC'0 <br />~ ro <br />lfl-u <br />f---4 . ..... <br />~ ~ <br /> <br />......t <br />~ ~ co <br />~ d ~ <br />~ 0 ~ <br />E--t -u I <br />Z ~ ~ <br />ro co <br />~ H co <br />~ <br />...--.. <br /> <br />Z ~ <br />~ Q) co <br />~ >--- <br />o ....-4 <br />~~ <br /> <br />~~ <br />~ ;j <br />~~ <br />~~ <br />uo <br />f---4C\1 <br />~ <br /> <br />@ COPYRIGHT, 2004 <br />H. THAYER HERSOM, ARCHITECT <br />AND ASSIGNED OTHERS. NO <br />UNAUTHORIZED USE OF ANY <br />PART OR ENTIRE DRAWING AS <br />PRINTED ON THIS SHEET. <br /> <br />lYP~dAL ROOF FRAM~NG PLAN NOTES <br />· i <br />1. UNLESS OTHERWISE NOTED ON PLAN, <br />ALL FRAMING TO BE PREMANUFACTURED WOOD ROOF TRUSSES AS DESIGNED BY A <br />L1CENSEDI STRUCTURAL ENGINEER IN THE STATE OF FLORIDA (LICENSE CURRENTLY ACTIVE). <br />2. ALL TRUSpES SHALL BE INSTALLED @ MAXIMUM 24" o.c, <br />3. ALL TRUSpES SHALL HAVE MINIMUM TWO-POINT BEARING WITH THREE-POINT (OR MORE) <br />BEARINQ ITYPICAL WHERE POSSIBLE AT HIGH UP-LIFT AREAS SUCH AS PORCHES, ETC. <br />4. THIS PLA~ AS INDICATED is DIAGRAMA TICAL IN NATURE FOR PERMIT AND, CONTRACT <br />PURPOSE~ ONLY. ANY REVISIONS AS REQUIRED BY THE TRUSS COMPANY S ENGINEER <br />AS INDICATED ON TRUSS COMPANY'S SEALED DRAWINGS SHALL SUPERCEDE THIS DRAWING, <br />5, TRUSS COMPANY'S SPECIFIED HURRICANE AND OTHER ANCHORS SUPERCEDE ONE SHOWN ON <br />THIS DRAWING, <br />6, ANY REVISIONS OR ADDITIONS OF AND TO BEARING WALLS AS SHOWN OR IMPLIED ON <br />THIS DRAWING SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IN A TIMELY <br />FASHION lAND IN WRITING OR DRAWING FORM. <br /> <br />NOTE: PER CHAPTER 16, 2001 FLORIDA <br />BUILDING CODE, THIS ADDITION IS <br />A 'PARTIALLY ENCLOSED' BUilDING, <br /> <br /> DRAWN <br /> HTH <br /> CHECKED <br /> HTH <br /> DATE <br /> 4/14/04 <br /> SCALE <br /> AS NOTED <br /> JOB NO. <br /> 04026 <br /> SHEET <br /> A=2 <br />OF A-2 SHEETS <br /> <br />PER SECTION 1606.1.8, THiS STRUCTURE <br />LIES WITHIN EXPOSURE CATEGORY 'B' <br />FOR WIND LOADS, <br /> <br />DESIGN LOADS <br /> <br />WIND: 120 M,P,H. <br />ROOF L.L. 20 P.S.F, MIN. <br />D,L. 10 P.S,F. MIN. <br />GARAGE SLAB 100 P,S,F. <br />LIVING AREA <br />L,L. 40 P.S,F, <br />D,L. 15 P.S.F. <br /> <br />SHEAR WALLS <br />NOTE: ALL MASONRY PERIMETER <br />WALLS ARE TO BE CONSIDERED <br />SHEAR WALL SEGMENTS EXCEPT <br />A T DOOR AND WINDOW OPENINGS <br />AND WALL LENGTHS LESS THAN <br />2' -8" IN LENGTH, <br /> <br />WINDOWS & DOORS <br /> <br />NOTE: ALL WINDOWS AND DOORS <br />INSTALLED ON THIS PROJECT MUST MEET <br />120 M.P.H. WIND RESISTANCE PER 2001 <br />FLORIDA BUILDING CODE, <br /> <br />..."",~--""~---""""-~..-......,.......... <br /> <br />/,,// '....~ <br />THESE CONSTRUCTION DOCUMENTS HAVE ;/ \ <br />BEEN PREPARED BY H, THAYER HERSOM,,: \ <br />~~~~~~CCTE~~~IE~E~,o A~6~~t~) ~~S :~E ( Ii <br />APPLICABLE SECTIONS, 2001 FLORIDA BUILDING CODE. \ I <br />\ <)(~ / <br />\. ) I <br /> <br />,,~, / <br />'-"'--, ".// <br />""'--....~~._...-.............. <br /> <br />PLANS <br />