Laserfiche WebLink
<br /> <br />@ <br /> <br />GAF MATERIALS <br />CORPORATION <br /> <br />APPLICATION INSTRUCTIONS <br /> <br />~~~~~~~""~.~r~~~"'-'-- -.4...~...__""'- _t:'~_ n.:...o.;....:__IUL-.. ....-_ rw........,...,.-~_...__.-........ ____......-"-....-n1.~~r.""''"'''~..;:<.~.~.........~,_t(_,~~ <br /> <br />Timberline~ Series shingles come <br />in either 36" (914mm) or 36-15/16" <br />'(938mm) lengths, depending on <br />shingle brand, Application instruc- <br />tions apply to both, <br /> <br />f-- - ,- - 36" (914mml <br /> <br /> <br />f. 1-- ""~,, ,.",-".-. <br /> <br />\ 11.112" (2nnlill) <br />-+-'2,112" (318mm)' ~ <br /> <br />1 (~5/1Hn) . '.1/2" (3amm) --~ <br /> <br />1, 1/2" (38mm) <br /> <br />- I <br /> <br />'2" <br />(30-lmm, <br />I <br /> <br />I <br />-1-1 <br /> <br />I <br /> <br />GENERAL /NS-rRtJC.r/ONS --- " <br /> <br />. ROOF DECKS: For use on new or reroofing work~ver well.seasoned, supported wood deck, <br />tightly,constructed with maximum 5" (152mm) WI?e lumber, haVing adequate natl,holdlng <br />capacity and smooth surface Plyv,ood decking as recommended by The" Engineered Wood <br />Assn i!> acceptable, Plywood decks for Class A Installations must be 3!H (10mm) thiCk, or <br />yrealer with underlaymenls as noted below Shingles must not be fastened directly to insulation <br />or insulated deck unless authorrzed In writing by GAF Matenals Corporation, Roof decks and <br />eXisting surfacing material must be dry prior to applitation of shingles", , <br />. UNDERLAYMENT: Underlayment beneath sl1ingl~s has many benefit,S, Includ,lng preventing <br />'Nind driven rain from reaching the lntenor of the building and preventll1g sap In some wood <br />decking from reacting with aspnalt shingles Underlayment is also required by many code bod. <br />les, Consult your local building department for ItS requirements Where an underlayment 15 to <br />be Installed, a breather,type underlayment such as GAFMC's Shingle,Mate'underlayment IS rec, <br />ummended Underlayment must be II1stalled flat. WI\i)OUt wnnkles, '. ' , <br />. FASTENERS: Use of nails is recommended, (Staple speCifications and application <br />Instructions are available from GAF Materials Corporation, Contractor Services Dept. 1351 <br />Alps Road, Wayne, NJ 07470) Use only zinc coated steel or alumll1um, 10.12 gauge. <br />barbed, deformed or smooth shank roofing nails with heads 3/8" (10m;n) to 7/15" (12mm) <br />In diam<:ter. Fasteners should be long enough to penetrate at le~st 3/4 (19mm) Into wood <br />decks orjust through the plywood decks Fasteners must be driven flush.lVlth the surface <br />of the shingle, Over driving will damage the shingle, Raised fasteners ~llIlnterfere With the <br />sealin9 of tne shingles, For normal installation, four fasteners must be Installed per shll1gle, <br />a nominal 5.5/8" (143mm) up from the bottom of the shingle, to penetrate both layers of <br />..~ the-shlngle,- Fasteners musLbe...lnstalled_ approximately..J :::_1_112'- (25:38mlJ1) _aIld <br />11-112",12 -1 !2" (292-318mm) from each side, , <br />. WIND RESISTANT: These shingles have a s~ecial thermal sealant that firmly bonds ltle <br />shingles together after application when exposed fO sun and warm temperatures Shingles <br />instaDed In rail or Winter may not seal untlllhe folb/llng Spring, If shingles are damaged by Winds <br /> <br />These shingles must be nailed a <br />nominal 5.5/8" (143mm) from bottom <br />of shingles, as shown, to allow for <br />penetration through the double ply <br />area just above the tabs Nails should <br />remain unexpos~d, <br /> <br />. I I <br />15'5;~" I ~43mmJ <br />nommal unt:xposca <br />i and U,(cugh <br />I ""Ih '.,eos <br />, <br /> <br /> <br />Statluard NaHlrwJ ?al\arn ' fO\J:f" naJJs p&r ::it'llngle <br /> <br />... .." _T' <br /> <br />...a-_.. <br /> <br />~ <br /> <br />r ~--.. ... <br /> <br />('j Underlayment: Standard SloPe-4~12 (333mm/m) or n:ore , <br />, Application of underlayment; Cover deck With one layer of underlayment Installed, Without <br />Wrinkles Use only enough nails to hold underlhment In place untlf covp.red by sfllngles <br />Application of eave flashing: fnstall eave flashing sych as GAF Materials Corporation Weather <br />VI/atc\)" or StormGuard" LeaK Barner In locailtles whrre leaks may be caused by ':vater backing <br />up behind ice or debris dams Eave flashing must overhang the roof edge by 318 (10mm) and <br />extend 24" (61Omm) beynnd the inside waif line I <br /> <br />4" i1Q2mmi~ ,. _ Deck <br />12-(305mm) y:'---~_~__ <br />Mlnlmur:1 SIope,0 ~,>;~ <br />For lower slopes see Sex 1a ,'-~~/,-:./?- <br />~:, <br />. .-~::.- <br /> <br /> <br />Weather Walcl1' <br />or StormGuaro' <br />leak a"rrier <br /> <br />r- <br /> <br />Ail sheets are 36" (914mm) <br />.vIde Shingle,Male" <br />undef1aymenl. <br /> <br />4" (102mml End lap <br /> <br />Aiong rake, place <br />drip edge on lop <br />of under',aYn'enl <br /> <br />Along eaves put underlayment <br />on 100 01 metal drip edge <br /> <br />4"'3 Underlayment: Low Slope 2/12-4/12 (167mm-333mm/m) <br />,~ Application of underlayment and eave f1asring: Completely cover the deck With two <br />layers of underlayment as shown, Use only ~nough nails to hold underlayment in place <br />until covered by shingles, Use blind nailing for eave flpshings At eaves and where ice dams Cen <br />be expected, use one layer of GAF Materials corporat~on Vfcather Watch' or StormGuard" Leak <br />Bamer, Eave flashing must overhang Ihe roof cd e y 3!8" (10mm) and extend 2'1" (610mm) <br />beyond the II1side wall line, Wllere ice dams or de~ri. dams are not expected, install 2 plies of <br />Shlngle.Mate' unflerlaYJ11ent <br /> <br />Low siope <br />2' to 4" L--_ <br />(Slrrlln '0 102mm) ~ <br />12" (305mm) <br /> <br /> <br />All sheets are 360 (914mm) <br />Hide Shingle,Male' <br />'Jnderlaymenl , J <br /> <br />Rake dnp edge <br /> <br />3i8" (lOmm) Rool overhang <br /> <br />2 <br /> <br />Starter Course <br />Apply as shown <br /> <br />StaC't at either rake and <br />!ay ;" eithe' direction <br /> <br /> <br />Non,corroding <br />Mp.tal Drip Edge <br />'\ <br /> <br />For m3:1:Inlum wine! resist~nc9 <br />along rakes. cement shing1es <br />10 underlayment and oach <br />other 'n " 4" (102mm) widlh <br />of ;:'lSDh~ll plastic r(){)f cement <br /> <br />P'aca shingle 3i8" (lQmm) <br />ever eave and rake edges <br />10 provide drip edge <br /> <br />Trim tabs off al\ s\after course <br />shingles, lhen place and nail <br />as shown, 3- to 4" (76mm tn <br />l02rnm) from ert'ie <br /> <br />3 <br /> <br />, <br /> <br />I <br /> <br />I <br /> <br />First Course I <br />Start and continue Nith full shingles laid flush fvith the starter course, Shingles may he <br />laid from left to right or right to left. DO NOT lay shingles straight up the roof since this <br />procedure can cause an incorrect color blend t the roof end may damfiqr. thr. shingle<; <br /> <br /> <br />I <br /> <br />Place Shm91€~ <br />close l~eU1ef but <br />dor. t Clc'Hd <br /> <br /> <br />Conti r'l ue <br />~rst COUfS.o? <br />. ,....,lh.....t-ol<'l <br />I 3ringiE'li <br /> <br />SI;H1 ~rs~lco'..'[se -!-11th wnc1e s,";ng;~ p{<1C~d 3,'8~ (10~fT1) <br />:;v€r p.aY~ (l/l(j ~~~~ f"(lges 1n pfnvide diip p{j()~ <br />i <br /> <br />-~ <br /> <br />8" (203mm) . 9" (229mm) ~\ <br /> <br />I U" (356mm) <br />- 15'. (381mm) ... ~ <br />I-+-' -'-- ~ <br />, (25mm}. 1,"~" (38mm)-~ <br /> <br />Re-Roofing <br />If old asphalt sning[es arc to remain in place, nail down or cut away all loose, curled or lifted shin. <br />gles: replace with new: an~ just before applying the new roofing, sweep the surface clean of all loose <br />BebrlS, Since any Irregularities may show through the new shingles, be sure the underlying shingles <br />prOVide a smooth surface, Fasteners must he or sufficient lengtfi to penetrale tl,e wood neck at leilst <br />311' (1 9mm) or Just through ply.'1ood, Follow other above instructions for applicatiOf1, <br />NOlf? Shingles can be applied over wood shingles wt:en precautions have been taken to provide <br />an acceptable smooth s~rface: This includes cutting back old shingles et eilves and rakes and <br />Installing ne'N wood edging strips as needed, Make surface smooth and use beveled wood strips <br />If necessary, Install tt30 underlayment to maintain Class A rating <br /> <br />r1lis ~roducl IS SOld with an express LIMITED WARR^NTY only, ^ co~y 01111e LIMITED WARRANTY stating I(S <br />terms and reSl,lcllons IS pnnted on the product wrappC' or may be obl~ineC from Ihe d,<;lributor of II;[s product or <br />dlrpctly [rom GAr Materials Corporilllon My (Ievi~tlrn Irom prinlcd Instructions shall be the resoonSlblllty 01 <br />~pnl;r.~lor "noh, 'f1i'"rrl <br /> <br /> <br />. I <br /> <br />I 5,5;8" (143mm) <br />: nominal unex;Jo~l::!d <br />I and Ihrough <br />both la,"rs <br /> <br />\ <br />\ <br />\ <br />\ Nail Gvi(,Ja <br />Lll,e <br /> <br /> <br />SIX ".Ii P altern <br /> <br />- <br /> <br />.... # J'oill. <111..,.- ............ "9>__,,, <br /> <br />" ....---.-. <br /> <br />....,~_.... --- <br /> <br />.-.a:'1:"""~~~ <br /> <br />- <br /> <br />~~ <br /> <br />before sealing or are not exposed to adequate surface temperatures, or If tr,e self.sealant gets <br />dirty. the shingles may never seal. Failure to seal under 1I1ese circumstances results from the <br />nature of self.seallng shingles and is not a manufactuflng defect To Insure Immediate sealing, <br />apply 4 quarter-sized da~s of Sl1in~le tab adhesive on the oilck of the shingle 1" (25mm) and 13" <br />(330I1lm) in from each Side and 1 (25mm) up from bottom of the shingle, TIle shingle must be <br />pressed firmly into the adhesive, " , <br />NOTE: Application of excess tab adheSive can cause blistering of Lhe shingle <br />For maximum Wind resistance along rakes, cement shingles to underlayment and each other In <br />a 4" (102mm) width of asphalt plastic roof cement , ' <br />NOTE The film strips on the back of each shingle are to prevent sticking together of tJ1e slllngle:> <br />"mile in the bundle, Their removal IS NOT required' dunng application, <br />. CANADIAN COLD WEATHER APPLICATIONS: CSA 1215.M90 mandate!> that sl11n. <br />91es applied between September 1 and April 30 shall be adhered with a compatible field,applied <br />adheSive, See Wind Resistant for GAF Materials Corporation's recommendations for the appli- <br />cation of that adhesive, <br />. MANSARD AND STEEP SLOPE APPLICATIONS: For roof slopes greater than 21" <br />(1750mm/m) per foot (do NOT use on vertical side walls), shingle sealing must be enhanced by <br />hand sealing, After fastening the shingle in place, apply 4 quarter. sized dabs of shingle tab adl1c- <br />sive as inr1icated in Wind Resistant above The shingle must be pressed firmly Into the adheSive, <br />. EXPOSURE: 5" (127mm) <br />. THROUGH VENTILATION: All roof structures must be prOVided wilh through ventilation to <br />prevent entrapment of moisture laden air behind roof sheathing, Ventilation provisions must at <br />least meet or exceed current FHA" H,UD, or local code minimum requirements, <br />. NON-CORROOIN<rMETALORIP'EDGES:Recorrlmenaedai0i1grak'e al1d eave-edges on-- ._'U_ <br />all decks, especially plywood decks <br />. ASPHALT PLASTIC CEMENT: For use as shingle tab adhesive Must conform to ASTM <br />D4585 Type I or II. <br /> <br />Precautionary Notes <br />Timberline" Series shingles are fiberglass, self'sealing asphalt shtngles, Because of the natural <br />characteristics of \Ile high quality waterproofing metenal used. these shingles will he stiff in cold <br />weather and fleXible in fiot weather. <br />1 Bundles SllUUld nut be dropped on cdge nor should attempt be made to separate shingles by <br />"hrri1king" over ridge or other bundles, <br />2 HRndle carefully, Shingles can easily br. brcken in cold weather or their edges damaged in 110t <br />weather <br />3 All exposed materials must be of Class A type <br />4 Storage should be in a covered, ventilated area-maximum temperature 110'F (430C) Store <br />on flat sur face and use weight equalization boards If pallets are to be double stacked, <br />Shingles must be protected from weather Nhen stored at job site, [)o not store np.ar stefim <br />pipes, radiators, etc, or in sunlight. All rolled product must be stored on ends <br />5 If <;hingles are to be applied dUTlng PROLONGED COLD periods or in areas where airborne, <br />dust or sand can be expected before sealing occurs, the shingles MUST be hand sealed <br />See Wil1,d Resistant instructions <br /> <br />4 Second Course <br />Start and continue second course as shown, Trim 5" (152mm) from Lhe end of the <br />!>hingle, Position the shingles in the second and subsequent courses flush w:th the tops <br />of [[le wi,de cutouts, This results in a 5" (127mm) exposure, Continue with full wldtl1 shingles <br />across tne roof, Stflke a chalk line about every 5 courses to check parallel alignment 1'11[[1 <br />eaves, NOTE Shingles may be laid from either <br />left or fight hand Side, Start at either rake <br />edge w:tn shingles having 6" (152mm) <br />trimmed from rake <br /> <br />B Wall Flashing (Sloped Roof to Vertical Wall) <br /> <br />'-'''"'", l,l- Siding <br /> <br />5" (127mm) 'vi;" <br /> <br /> <br />I T ~etal Flasr'''g <br />"'" (Na,'ed '0 the deC1<, nollo/e't'cal s,de...-aH) <br /> <br /> <br /> <br />- ~~"",~,., CapSh!r,g'e-DoNotNail <br />~____lnS,\all w'th Rocnng Cecr,enl <br /> <br />"~ ~ Roonng Cement <br /> <br />___ Shng:e <br />-+-- Roof Deck <br /> <br /> <br />Trim Sr,lngll.:-l! <br />6. {\52mrr.;' <br /> <br />5 <br /> <br />Third Course <br />Trim 11" (279mm) from the flr~t sl1ingle in tile course then continue \^iltll full shingles <br />across lt1e roof <br /> <br />CMck.e I on <br />t'iigh ~id(t 01 <br />cruml"1ey <br /> <br />9 <br /> <br />Chimney Flashing <br /> <br /> <br /> <br />~~nn-(:orrTll1lnQ metal t;,se nashing <br />One piC'!ce S',pp nasi'1inQ for e;;sct1 ,=o'.Jf'se <br />Cement in place ~:'Id nai,1 'Nlth '2 ~la115 <br />Bnnd o"e~'f11"'19 s~ingie1 ,.... asol"atl <br />DI~!'.Hc cement <br /> <br />",\ <br /> <br />. <).I'f.. . , <br /> <br />\'," ...' <br />, -, <br />, , , <br />\. \. ... '\ <br />, ".' , <br />'\ ,. '\ ., <br />I' '\, ... <br /> <br /> <br />;:Ifflmud S!",lngles. <br /> <br />6 <br /> <br />Fourth Course and Remaining Courses <br />Irim 17' (432 111m) from first shingle in lhe course. then continue With tull shingles across <br />the roof FlfU1 and subsequent courses repeal full shingle Instruction) from Step 3 <br /> <br />10 Valley Construction-Closed Cut <br /> <br /> <br />Genter full H1o:tl rOll <br />01 Wca:,,"'lef,Vatctl. <br />C( Slorm(;\.'at~ ____ <br />Leak. '3an-icf (0" (\ 521T'fT1! <br />~n<1I."lpc;) in \loJl~y <br /> <br />vane.,. Ccn~(>r1if'\e <br /> <br />E;d:a fil'Slcf1cr ir <br />el'd 01 sninq10 <br /> <br />, <br />, <br />, <br />, <br />/- <br /> <br /> <br />~un stiV~e-r Ship al'd first <br />sh.ingj@: COlJf sQ en!y acros s <br />'tn/l{'y . 2'" (JOSml1"') rT"ir,.r'f\vl"l' <br /> <br />FdHl CQur~e <br />Full S~:ngle <br /> <br />.. <br /> <br />NO fastc"lcrS "",Ul1n <br />6~ (152~mi 01 cOll'.e!:ine <br /> <br />Fourtll Cours<: <br /> <br />E..tlend 8M shll1o;:e <br />Bit fS<'lst , 2- n05mm) <br />beyont1 ~F\r.e'Y renladir,A <br /> <br />C:;ppe-d crXflef' se! <br />in roofing ~el~.ef'1! <br /> <br />:r::1lnled Shlflgle~ <br /> <br />1 Hip and Ridge <br />For Single lay<:r application, use hip and ridge shingles and apply oS ~hol'ln To er,hance <br />appearance, use GAF TIMBERTEX' or a double layer application of Universal Hip & Ridge <br />(One bundle of TIMBERTEX' Hip & Ridge covers 20 lineal fl-6,1 meters,) For double application, <br />start with triple thickness of precut Hip & Ridge shingles and continue remainder with double <br />thickness, fasten in same manner as single applicalion sllown Apply laps away frorn prevailing <br />Wind direction <br /> <br />11 Valley Construction-Open <br /> <br />O.x;)CSUiS <br /> <br />Nail 5-5ia" (143mm; <br />from bol1om and <br />1" (25mm) from edge <br /> <br /> <br />Ic-p !1fv<J;1~.,. f). ',152I"lml <br />......'de ~lw(:'cn sbl'o;les <br />SDr~a.::t. tiS"; 1 Gmf;1/'r,,; <br />pot root !c'm\rr1 e;\,<"~ <br /> <br />Can:e' h.:lI....;dt'h rcd <br />01 vV!:atller 'N,,~c:-," Cf <br />SlorlT'G("jar'O''' Le~k n<\'u.r <br />(6.1,152~.rr.\ end ',10'<;1 <br />;n v~lJey <br /> <br />Sc<u!e I"~ ft1el.ll 0.JS!11119 <br />"""U"ClJt plJr<t....nf17 by r.JfI1:;P'; <br />rQ0{,ng r"Jd'S C''-~')' 1 r l(l 1~- <br />6g~Ojl\;~'t~~~~~:~~~'9 cd~(1 <br />l~le~.1l .. .l::.f>y <br /> <br />B" 1203mrn) eXPO,Ur~ <br /> <br />Cer-,ler 2Q":S08/1lm) <br />Me.. ro"~<;onodi"g., <br />:~a~t~n:~le;'~ ~a'.I~e <br />Minlrrum 4' (1C2rT'iM) <br />'.If'\C,flf !hll"c{e, <\1 !'!4'.e <br /> <br />Emoc'J sJlill~l€<; 't" <br />- - - - ')"01'.'11 rja!;~\c <br />>:e""'cn!;.., ...,:),1e. <br /> <br />Bend H,p & Ridge shIngle <br />centered over Hip or Ridge <br /> <br /> <br />~-A .~ <br /> <br /> <br />S' (127mrni t <br /> <br />ROOF DL\.PIIRA.wI NAILING SCIIEDULE <br /> <br />K'IO~~ uJ~ <br />~ <br /> <br /> <br />~ <br />ti) <br />~ <br />\f <br /> <br />RI l7t, ~ LI JE::. <br /> <br />120 wIPII 3 SECOND GUST EXPOSURE "B" \VIND ZONE <br /> <br />3d Common Nails @ 6" o,c. & --l" a.c. @ Gabie End W:111 or Gabie Truss <br />,13 Ix 2 '12" Long Gun n:1i I @ --l" o.c, <br />,120 x 3" LDng Gun n:1il @ --l" o,c, <br />,113 ,'( 2" Long Gun nail @ 3" o,c, <br />-n----.09C'-----x.2 1~..tangGu]'fnjjr@ 3"o~C-~- _.~- ---, <br /> <br />~ <br /> <br />120 wIPII 3 SECOND GUST EXPOSURE "B" \VIND ZONE <br /> <br />8d Common Nails @ 6" o.c, Edges & 8d Common Nails @ 12" o.c. Intennediate <br />,131 x 2 '12" Long Gun nail @ -1" o,c. Edges & S" o.c. Intermediate <br />,120 ,x 3" Long Gun nail @ r O.c, Edges & S" o,c, Intermediate <br />,113 x 2" Long Gun nail @ 3" o,c, Edges (Staggered) & S" o,c, Intem1ediate <br />,099 x 2 W' Long Gun nuil @ 3" o,c Edges & S" o.c, Intennedi:1te <br /> <br />I <br /> <br />I <br /> <br />NOTES: <br /> <br />1,) See Structural Notes for sheathing specific:ltions and wind speed. <br />2,) End joints of the roof sheathing shall be staggered and occur over fraITIlng member, <br />3,) Schedule assumes she:1thing is fastened directly to Southern Yellow Pine or Douglas <br />Fir or better, <br /> <br />1 1/2' SAW.CUT SLOT <br />SHY SlOT 12' SHOflT OF <br />Mf( RI[)GE END. <br />INTERSECTION <br />AND/<::xl 08SmUCnOO, <br /> <br />NOTES: <br />· END CAPS TO BE LOCATED <br />OVER EXPOSED ENDS OF <br />FIRST AND lA5T SECTla-lS, <br />CAUlK BETWEEN BOnOM <br />EDGE Of END CAP AND ROOF, <br /> <br />· INSTAll RIDGE VENT CONT. <br />n-u: ENTIRE LENGTH OF RIDGE, <br /> <br />· RIDGE VENTS SHOULD N.WAyS <br />BE INSTAlLED WlTH SOfFITI <br />EAVE INTA.l<ES a: EQUAL <br /><X{ GREA]ER MEA. <br /> <br />· REFER TO MANUFACTURER'S <br />DCTNlS ANS SPECS. <br /> <br />I <br /> <br />~ <br />I <br />J <br /> <br /> <br />METAl. ROOF CAP <br />TO MATCH METAl ROOF <br /> <br />C<X{AVENT RJDGE <br />VENT on SIMIl.AJ\ <br />(TO MATCH ROOF SLOPE) <br /> <br />NNLS TO BE LONG <br />ENOUGH TO PENETRATE <br />VENT AND ROOf <br />SHEATHING; NAIL HEAD <br />SHOULD BE FLUSH 'IvHH <br />TOP OF SHINGLE, <br /> <br />1/2' EXT. <br />PL YVlooO <br /> <br />PRE. ENGINEERED <br />ROOF mUSSES <br /> <br />RIDGE VENrr INSTALLf\TION DETAIL <br /> <br />SCALE: N.T.S, <br /> <br /> <br />REVISION BY <br /> <br />~ <br />U <br />W <br />~ <br />I <br />U <br />er.:: <br /><t: <br /> <br />L[) <br />" <br />--- <br />CO <br />I <br />to <br />CO <br />N <br /> <br />~ <br />r<) <br />--- <br />CO <br />'-.-/ <br /> <br />"' <br /> <br />2 <br />o <br />if) <br />er:: <br />w <br />I <br /> <br />I <br />0... <br />r<) <br />N <br />to <br />r<)<D <br />r<)'"' <br />'"' <br />.- <br />___<I <br />r<)o<D <br />r<) rv-~ <br />...j-U-,-... <br />1"'\.1 0 t<) <br />I. ~ ---1 ro <br />xlL.'--" <br /> <br />g<~ <br />o..~ <br />.2"'- <br />.~<x <br />I o...~~ <br /> <br />er:: <br />-w <br />>- <br /><t: <br />I <br />~ <br /> <br />~1 <br /> <br />,1,'';'~": <br /> <br />i~ <br /> <br />"'~ ~1 ~] <br />I <br />[~ <br />~ ~ [U <br />I ~ I ~3::~ <br />flj <br />~] I ~j <br />i>"~ <br />I "",;~ <br />~";,o <br />~1 ~] ~l <br />"'.~ <br />t~T <br />~"j ~~ <br />ti.l <br /> <br />~~ <br />~lj <br /> <br />~~ <br /> <br />~~ <br /> <br />~ <br /> <br />~ <br /> <br />00";;) ,"",~ <br />~~ <br /> <br />~~ <br />~-:~;,! <br />t:tl <br /> <br />r~.i f~ ~~~ <br />".,i,'~~ ",,;.j <;"!.,j <br />~J if:~ kg <br /> <br />@ COPYRIGHT, 2002 <br />H. TI-iAYER HERSOM, ARCHITECT <br />AND ASSiGNED OTHERS, NO <br />UNAUTHORIZED USE OF ANY <br />PART OR ENTiRE DRAWING AS <br />PRiNTED ON TI-iIS SHEET. <br /> <br />DRAWN <br />CHECKED <br />HTH <br />DATE <br />SCALE <br />AS NOTED <br />JOB NO. <br />SHEET <br />8=4 <br />