Laserfiche WebLink
<br />1,1 <br /> <br />ENGINEER/S <br /> <br />NOTES: <br /> <br />ALL wORK TO BE COMPLETED ACCORDING TO THE 2001 EDITION FLORIDA BUILDING CODE <br /> <br />1. <br />2, <br />3, <br />4, <br />5, <br /> <br />wIND DESIGN SPEED 110 MPH (3 see gust) I <br />THE wIND IMPORT ANCE F ACTOR IS 1.0 FOR RESIDENTIAL HOME <br />THE wIND EXPOSURE FOR BUILDING IS CA TEGORY IIBII <br />THE APPLICABLE INTERNAL PRESSURE COEFFICIENT = +,18/-,18 <br />THE DESIGN wIND PRESSURE COMPONENTS ~ CLADDING (ROOF) <br />ZONE 1 ZONE 2 <br />@ 10 SQFT +12,5/-19,9 @ <br />@ 20 SQFT +11.4 /-19,4 @ <br />@ 50 SQFT +10,0 /-18,6 @ <br />@ 100 SQFT +10,0 /-18,1 @ <br /> <br />10 SQFT <br />20 SQFT <br />50 SQFT <br />100 SQFl <br /> <br />+12,5/-42,1 <br />+11.4/-38,2 <br />+10,0/-33 <br />+10,0/-29,1 <br /> <br />ALL ROOF CLADDING PRODUCTS ARE THE RESPONSIBILITY OF THE MANUFACTURER, THE ROOF CLADDING MANUFACTURER IS RESPONSIBLE FOR <br />THE VALIDITY OF COMPONENTS PROVIDED, ATTACHMENT INFORMATION GIVEN BY THE MANUFACTURER IS PROVIDED HEREIN, CONTRACTOR) AS <br />PROJECT CORDINATOR) SHALL BE RESPONSIBLE FOR INSURING THAT THE APPROPRIATE ROOFING MATERIAL IS USED AND THAT IT HAS BEEN <br />INSTALLED PER MANUFACTURER'S SPECIFICATIONS SUCH THAT IT ~ILL ~ITHSTAND THE COMPONENTS AND CLADDING PRESSURES REQUIRED BY <br />THE SEALED PLANS, <br />..,....~~~~" <br />ALL PRE-ENGINEERED ~ooD PRODUCTS SHALL BE VERIFIED BY TRUSS MANUFACTUERER, TRUSS MANUFACTURER SHALL HAVE THE AUTHORIT'r"'~--' <br />TO MAKE SUBSTITUTIONS FOR PRODUCTS SPECIFIED ON THE PLANS DUE TO AVAILABLITY OR ECONOMICS, CHANGES SPECIFIED BY THE TRUSS <br />MANUFACTURER SHALL CONTROL, CHANGES MADE AFTER TRUSS ENGINEERING HAS BEEN PROVIDED TO ENGINEER OF RECORD) MUST BE <br />APPROVED BY THE ENGINEER OF RECORD, <br />THE ENGINEER HAS NOT REVIEWED THE PRE-ENGINEERED TRUSS MANUFACTURER'S LAYOUT TO DETERMINE ANY LOAD BEARING CONDITIONS <br />AND RESERVES THE RIGHT TO MAKE ANY CHANGES AFTER TRUSS LOAD INFORMATION IS SUPPLIED TO THE ENGINEER, <br />ALL PRE-ENGINEERED TRUSSES TO BE DESIGNED USING THE MOST RECENT TPI CRITERIA, TRUSSED TO BE HANDLED AND INSTALLED USING MOST RECENT <br />HIB RECOMMENDATIONS, TEMPORARY AND PERMANENT BRACING SHALL BE PER MOST RECENT HIB RECOMMENDATIONS UNLESS NOTED OTHER~ISE) OR <br />MORE STINCJENT CODE REQUIREMENTS APPL y, TRUSS ENGINEER IS RESPONSIBLE FOR INDICATING ALL TRUSS CONNECTIONS, ALL COMPONENTS TO BE <br />DESIGNED ~[lR BOTH GRAVITY AND UPLIFT LOAD CASES, INCLUDING BEAM COMPONENTS, <br /> <br />;;"{..'1" <br /> <br />6 , THE DES I G N wIN D PRE S SUR E CO iv1 P 0 N E N T S ~ r LAD DIN G ( w A L 1_ S ) <br /> <br />ZONE 4 Zl JNE 5 <br /> <br />@ 10 SQFT +21.8 /-23,6 @ 10 S 1FT +21.8/-29,1 <br />@ 20 SQFT +20,8/-22,6 @ 20 S!lFT +20,8/-27,c <br />@ 50 SQFT +19,5 /-21.3 @ 50 SI 'I=-T +19,5/-24,6 <br />@ 100 SQFT+18,5/-20,4 @ 100 ~. )FT+18,5 /-22,6 <br /> <br />THE ATTACHMtNT OF ASPHAL T SHINGLES ON THIS PRODUCT MUST BE IN COMPLIANCE WITH ASTM D3161 (MODIFIED TO 1l0MPH) DR M-DC PA 107-95, <br /> <br />TIMBER MA fERIALS: <br />ALL TIMBERS M/'\ fERIALS SHALL BE AS FoLLo~S: <br />LUMBER UTILIZED IN BOTTOM PLATE) TOP PLATES) POST) STUD PACKS AND BEAMS SHALL BE #2 YELLOW PINE (OR BETTER), <br />EXTERIOR AND INTERIOR LOAD BEARING STUDS SHALL BE #2 SPRUCE (OR BETTER), ALL OTHER STUDS SHALL BE HSTUD GRADEH <br />SPRUCE SPACE 16" O,C" ALL SPLICES AT TOP PLATE MUST BE MINIMUM 4/-08 AND NAILED 4" O,c' W/ 12d COMMON NAILS, <br />EXTERIOR ~ALLS SHALL BE CONSTRUCTED ~ITH 1/2/1 PL Y~OOD DR 7/16H O,S,B, (2-M-~ RATING) NAILED ~ITH 8d NAILS SPACED AT <br />3" O,C, ALONG ALL HORIZONTAL JOINTS AND EDGES, 68 O,C, ALONG ALL VERTICAL JOINTS AND EDGES AND 12" O,C, ALONG ALL INTERMEDIATE STUDS, <br /> <br />ALL OPENINGS 5'-0" ~IDE OR LARGER STRAP HEADER BEAM TO THE HEADER STUDS ~ITH SIMPSON LSTA24 STRAP TIES AT EACH END <br />OF HEADER BEAM, ANCHOR BOTTOM OF HEADER STUDS TO FOUNDATION ~ITH SIMPSON HTT16 TENSION TIE, <br />INTERIOR STUD WALLS TO BE OF 2X4 #2 SPRUCE DR BETTER ~ITH SINGLE 2X4 P,T, PINE BOTTOM PLATE AND SINGLE 2X4 #2 SPRUCE TOP PLATE ~ITH <br />STUDS SPACED MAXIMUM 24/1 O,C, WALLS TO HAVE 1/2" GYPSUM BOARD EACH SIDE) WITH WALLS AT GARAGE TO HAVE MIN R-ll INSULATION, <br /> <br />ANCHOR ~oOD SHEAR ~ALLS SEGMENTS TO FOUNDATION WITH SIMPSON LTT20B TENSION TIE AT EACH END OF ~ALL SEGMENTS AND AT ANY <br />WALL SEGMENT INTERSECTION (BUILDING CORNERS), <br /> <br />ANCHOR TRUSS WOOD BEARING LOCATIONS AS FOLLOWS: <br />ROOF UPLIFTS OF 905# AND LESS USE (D SIMPSON H10 HURRICANE TIE <br />ROOF UPLIFTS OF 1450# AND 905# (D SIMPSON HTS20 T~IST STRAP, <br /> <br />GENERAL NOTES: <br /> <br />WINDO~ AND DOOR MANUF ACTURERS TO PROVJ DE CERTIFICA TIUN/RA TING THA T THEIR ~INDU./S AND DOORS <br />~ILL WITHSTAND THE PRESSURE RESUL TING r-ROM THE SPECIFIED DESIGN COMPONENTS AND I_ADDING ~IND <br />PRE S SUR E AND PRO V IDE INS TAL L A T ION IN FOR MAT ION WIT H THE I R PRO D U C : ';, <br /> <br />CONTRACTOR TO INSTALL ~INDOWS AND DOORS ACCORDING TU INSTRUCTIDr~ SUPPLIED BY MFGR AND HAVE <br />MAUFACTURERS SPECIFICATIONS (CUT SHEETS) ON SITE AT THE TIME OF Jf ,SPECTION FOR REVIEW BY THE <br />BUILDING INSPECTOR, <br /> <br />ALL HURRICANE CLIPS, STRAPS AND FASTENERS ARE TO BE APPLIED ACCf1f(DING TO THE FASTENERS <br />SCHEDULE AND MANUFACTURERS SPECIFICATIONS. IF DESIRED; EQUAL VEN; CONNECTORS MADE BY ANOTHER <br />SUPPLIER MAY BE USED IN PLACE OF THE CONNECTORS SHOWN, <br /> <br />DESIGN NOTES: <br />ALL CONSTRUCTION SHALL BE APPROVED IN ACCORDANCE WITH FLORIDA B1'ILDING CODE) OSHA, AISC) AWS D 1.1 CODES AND ALL <br />APPLICABLE LOCAL REQUIREMENTS, THE STRUCTURE IS DESIGNED TO COMP' Y WITH THE 2001 FLORIDA BUILDING CODE, BUILDING BASE <br />CONNECTIONS SHALL BE PROVIDED AS SHOWN. ALL MATERIALS IDENTIFIED BY MANUFACTURER NAME MAY BE SUBSTITUTED ~ITH <br />MATERIALS EQUAL DR EXCEEDING ORIGINAL RATINGS, <br /> <br />TRUSSES: <br /> <br />JOB NOTES: <br /> <br />IF THE CONTRACTOR) TRUSS MANUFACTURER DR ANY OTHER DESIGN PROFESSIONAL RE VISE THE TRUSS SYSTEM LAYOUT FROM THOSE SHO~N ON THESE <br />PLANS) THE ENGINEER OF SIGNATURE IS REQUIRED TO REVIEW ALL FINAL CONSTRUCTION DOCUMENTS FOR COMPLIANCE WITH THE DESIGN <br />INTENT PRIOR TO COMMENCEMENT OF THE PROJECT, <br /> <br />UP LIFT CONNECTIONS FOR MASONRY WALLS <br />ROOF UPLIFTS OF 1890# AND LESS USE (1) SIMPSON HETA24 ~ITH (16) 10d X 1 1/211 NAILS <br />ROOF UPLIFTS OF 2310# AND LESS USE (D SIMPSON HHETA24 'WITH (2D 10d X 1 1/21/ NAILS <br />ROOF UPLIFTS OF 3965# AND LESS USE (1) SIMPSON MGT WITH (22) 10d X 1 1/28 NAILS TO GIRDER AND 5/8H ANCHOR BOL T IN CONCRETE <br /> <br />ROOF UPLIFTS OF 10980# AND LESS USE (1) SIMPSON HGT-2 WITH (8) 10d X 1 1/2" NAILS TO GIRDER AND (2) 3/4" ANCHOR BOL T IN CONCRETE (2 PL Y GIRDERS) <br />ROOF UPLIFTS OF 10530# AND LESS USE (D SIMPSON HGT-3 WITH (8) 10d X 1 1/28 NAILS TO GIRDER AND (2) 3/48 ANCHOR BoL T IN CONCRETE (3 PL Y GIRDERS) <br />ROOF UPLIFTS OF 9250# AND LESS USE (1) SIMPSON HGT-4 WITH (6) 10d X 1 1/2" NAILS TO GIRDER AND (2) 3/4" ANCHOR BOL T IN CONCRETE (4 PL Y GIRDERS) <br /> <br />1) ADD NEW FRONT PORCH <br />2) REMOVE (3) FRONT ~INDO~S ON EXISTING STRUCTURE AND INSTALL NEW FRONT DOOR LOCATION <br />3) ADD NE'W BATHROOM OFF EXISTING BEDROOM <br /> <br />STRUCTURAL SHEATHING AT ROOF: <br />15/3211 CDX SHEATHING SHALL BE NAILED W/ 8d NAILS @ 611 O,C, <br /> <br />DRAFTSTOPPING: <br /> <br />~ . LCOVPLY\V1TI-lALL <br />ALL V, ORK ~HAL . I m T'\C\C <br />"GCODr.S Fl..ORlDABULL-J-.' ~ <br />pRE\' AlLr;~ '- . ODE \..'\' <br />, O~AL ELEClRlC C I J <br />CODl:,:--I1\ T1 j S ORDlNAJ'\CES <br />cn'Y OFZEPHYlUULL j <br /> <br />IN SINGLE FAMIL Y DWELLINS) DRAFTSTOPPING SHALL BE PROVIDED (PARALLEL TO THE MAIN FRAMING MENBERS) IN FLOOR / CEILING ASSEMBLIES SEPARATING <br />USEABLE SPACES, DRAFTSTOPPING SHALL BE CONSTRUCTED SUCH THAT THE FLOOR / CEILING ASSEMBLEY IS BROKEN UP INTO TWO DR MORE APPROXIMATED <br />AREAS WITH NO AREA GREA TER THAN 500 SQ, FT, <br /> <br />STRUCTURAL PANELS <br /> <br />NOTE: 1/2" PL YWOOD DR OSB STRUCTURAL PANELS SHALL <br />ROWS OF 10d NAILS @38 O,C, @BOTH MEMBERS OF DBL TOP PLATE AND DBL RO~ 10d @T' O.C, @ <br />PANELS SHALL HAVE NAILS AT SPECIFIED SPACING OF 3" O,C, <br />NOTE: ~HERE WINDOWS DR DOORS INTERRUPT THE WOOD STRUCTURAL SHEATHING <br />OPENINGS USE SIMPSON DSP AT ALL CONNECTIONS OF STUDS TO TOP PLATE ~ <br />(SIMPSON DSP RATED 825# UPLIFT) <br /> <br />f...:" '3f '/, .~.' ~ <br />; .i t: .__~.J 2.."'. .'i:- 0 ~.:- - .' /;) <br />f\!i' :::-.,;S O~i-'T ,\PFP.Oil:.D -.",. Q ~ ~\(,q <br />D <br /> <br />EXTERIOR OPENINGS: <br /> <br />IT WILL BE THE CONTRACTORS RESPONSIBILITY TO INSURE THAT THE WINDOWS AND DOORS ARE INSTALLED AS PER THE MANUFACTURERS <br />ENGINEERED DRAWINGS AND THAT A COPY OF SAID DRA~INGS ARE ON THE JOBSITE AT THE TIME OF <br /> <br />ALL INFORMATION ON THIS PAGE IS INTENDED TO BE CORRECT UT MISTAKES CAN BE MADE AND IT IS THE RESPONSIBILITY <br />OF THE CONTRACTOR TO VERIFY ALL INFORMATION PRIOR TO CO STRUCTION, <br /> <br />Do, vid w, SMith) P,E, <br /> <br /> <br />ENGINEER LICENCE ~53608 <br /> <br />I~OBER1~ I-IARrrWIG <br />39038 9TH AVE RICK GOLLHARDT - DRAFTSMAN <br />ZEPHYRHILLS, FL 33542 <br />J> ':i,'.SMI'-rlI~ P.E. ENGINEER NOTES SHEET OF <br />" "-~S[ONAL ENGINE[R !l~U~SE NUMBER 53608 D NO ES 1 OF 7 <br />PNOU'( /> ENGINEERINC CONSULTANT STANDAR T <br />gSiCr)' ^'~~ DRIVE-Di\ .~.; YY, FLORIDA 33525 ~CALE,,, DATE JOB NO, <br />PH~~:: FAX 352-521 ," '.'11'<] L: zephyr27@gte, net 1 /4 = 1 - 0 1 8 N OV 2004 . <br />DESIGN/DRAWN CHECKED <br />R. GOLLHARDT D.W.SMITH,P,E, <br /> <br />I hereby certify tho. t I ho' ve reviewed this plo'n o'nd found it to be in <br />cOMplio'nce with section 1606 of the Florido' Building Code) 2001 edition) <br />