Laserfiche WebLink
<br />MASONRY INSTALLATION <br /> <br />W <br />~ <br />l.L.<l:0::: <br />'00:::0 <br />W l.L.l.L. <br />~W"",f- <br />O..:::Z <br />~-O:::J <br />x~o:::o <br />0:::Jl.L.() <br />O:::OZ() <br />0.. ""'w <I: <br />O"..:::~f- <br /><1:0<1:0 <br />WO:::f-z <br />O:::l.L.w <br /><I: zo:::o <br />oW<l:O <br />W~(j)O <br />f-~zz <br />o 0<1: <br />:::JW-w <br />OO:::(j)"", <br /><l:Z..::: <br />~(j)W<l:z <br />~z~[fo <br />~QOoi= <br />0(j)0:::f-() <br />oZo~- <br />l.L.W~()o: <br />w~woo.. <br />~o~ffi<l: <br />:::J::j-.0::::::J <br />o <I: (j) 0 ~<l:: <br />(j)O::.-J........ <br />.-Jw.-JO <br />.-J>~ZO::: <br /><1:0::><1:0 <br /> <br />~~.-J ~il' <br />en 1U ~ ~ c:=J 0 <br />~'<:) ~ ~ <( en <br />~~tl:Ci? <br />I (/)0 ~ <br />en ~ 15: ~ <br />,.\ C 63 <br />~ 'OJ) IT: g <br />(Q'- - .-J <br />II. ~ 5:: ffi ~ <br />""..,W 0::: <br />.., "C () f- <br />E ~ <br />f--~ ~~~ W <br />~ S('I') ti <br />or.' _/r;--,., co 0 l.L. ~ <br />H- ~.Jl W r'-- 0 l.L. <br />~N ('I')<:t <br />z('l') ('1')0 <br />~_~ ~.-J ('1')('1') <br />o::l.L.NN <br />o . 00 <br />Q) uj~ ~~ <br />Lf) 0 r-- r'-- <br /><:t 0.. 0 0 <br />(i-~ (J) <I: <:t <:t <br /> <br />CAULK BETwEEN INSTALLATION ANCHOR INSTALLATlOI'~ ANCHOR -l_1/4d MAX SHI~ SPACE <br />wOOD BUCK 8, 3/16# DIA, TAPPER #8 \.IOOD SCREw (TYP, I.-mERE 1 1/4' NIN, <br />MASfY, OPENING (NOTE 17) TAPPERS ARE NOT I----....--EMBEDMENT <br />BY OTHERS CONCRETE OR ONE BY v/OOD REQfD, - NOTE 22) I . ONE BY \.IOOD <br />MASONRY OPENING 'I BUCK BY OTHERS I V6. - BUCK BY OTHERS <br />(NOTE 11 8, 122:\ <br />DOOR FLANGE -_ \SHIM AS /C\ r " LB~ <br />8.: wOOD BUCK REQ/D LID n ~ ~ --'> <br />PERIi'1ETER ~t~~s.7 SLIDING GLASS ." \ CAULK BETwEEN <br />CAULK BY 'V I 'Q 1 1/4' HIN t DOOR Fj~~~ \ <Q I.,/OOP BUCK 8, <br />OTHERS ,~ UIBEDMENT, r 1/4' MAX ". \, II.' ------------ ~~AS y, OPENIi'IG <br />v ~'r., i \ ~ BY OTHERS <br />1 t> .:-HIM SPACE \/1 : _____ SHIM AS REQiD, <br />::'s~ --=:: =::::-- 0--=0:: _~__ --- ~ U! 111~iL------, (SEE NOTE so <br /> <br />~~ug~8ERS Ir---J I ~ II ~ l \\~ lTrl\"'~ INSTALLATION ANCHOR <br />U \ _ ~ rnw.!. U ] \ 3/16' DIA, TAPPER (~mTE <br />t Lf II] II II tll'\'l!J ~ TEMPERED GLASS .. " <J ~-CAULK BET\.;EEN <br />~j I~ CTYP,) II ~ DOOR FLANGE <br />INSTALLATION ANCHOR V~l' 8< \";OOD BUCK <br />#8 SCREW' \.IOOD (TYP, ~ \. <br />y/HERE TAPPERS ARE SLIDING GLASS PERIMETER ______."...~. <1"\ <br />NOT REQ/D, - NOTE 22) L DOOR FRM1E I CAULK BY \\ CONCRETE OR <br />HEAD OTHERS I' ~ - MASDNR~ 9PENING <br />_............. SG.D. 'WIDTH _ BY OTHc.R.:::. <br />~ STUCCO <br />BY OTHERS <br />pi< TEMPERED srCTION B B <br />GLASS (TYP) C - <br /> <br />1\ CONCRETE OR <br />Llb.r--~ MASONRY OPENING <br />2X4, 2X6; DR 2X8 \,iOOD \ I . ~~ BY OTHERS <br />BY OTHERS (NOTE 6) \ '\ <br />/ \ <br />WSTALI_ATIm~ ANCHOR / iJ \ <br />#8 "";OoD SCREw <TYP) l / CAULK BET\.,IEEN <br />(NOTE 23) ~IDOk STRIP &: <br />(ANCHORS SHOwN IN $AHE \ iJ. 'w'OoD BUCK <br />PLANE FOR CLARITY ONLY X <br />HOOk STRIP ANCHOR HOLES <br />SPACED 2' APART ON I' ~L 1 1/8' MI. ~~"-. <br />OPPOSITE FLANGES) I: EMBEDMENT "- <br />(TYP) <J '\.~ <br />SLIDING GLASS DOOR -" \I,j .6 ~ "- <br />HOOK STRIP ,,\.1\ <J . . " /' <br />."" ' L,V <br />17) .~ T \~" .,y <br /> <br />TEfv1PERED GLAS7 ~. II" t ~ "1'''''''::':- 31f MAX <br /> <br /> <br />OYP,) n <br />< =~ -l i~U6~BERS <br />~~ II _SLIDING GLASS DOOR <br />~ INTERLOCK <br />HOOK STRIP DETAIL <br />IMPORTANT INFORMATION & GENERAL NOTES <br /> <br />lLJ <br />() <br />I- <br />o <br />Z <br />lLJ <br />(!) <br /><t: <br />I- <br />o <br />~ <br />lLJ <br />0:: <br /><! <br />::> <br />o <br />(f) <br /> <br />-- <br /> <br />SECTION A-A <br /> <br />f"1 <br />I <br /> <br />& <br />CAULKING AT FASTENER <br />HOLES REQUIRED <br /><SEE NOTE 2) <br /> <br />SLIDING GLASS <br />DOOR FRAME----; <br />SILL <br /> <br />::: <br /> <br />'--"'I <br /> <br />& <br /> <br />1/4' MAX <br />SHiM SPACE] , il <br /> <br />. '" t <br /> <br />.. <br /> <br />'!r <br />I <br /> <br />~ <br /> <br />LJ ~,LJ <br /> <br />INSTALLATION ANCHOR \ <br />#8 ''';OOD SCREw 1;/ IPLASTIC <br />ANCHOR (Typ, IJHERE <br />.Q TAPPERS ARE NOT REQ'D. \ <br />Lfu SEE NOTE 22) ~ <br />LlBERAlL Y APPL Y <br />CAULKING UNDER SILL <br />OR SET SILL IN BED <br />OF CONCRETE (SEE t-lDTE 2), <br />SHIM AS REQUIRED (SEE NOTE 1), <br /> <br />o <br />I <br /> <br /> I <br />JJ! <br />I <br />; <br />I "--" <br />I I <br />I <br />I <br />G ii' <br /> .6 <br /> <br />"" <br /> <br />CAULKING &, <br />REQUIRED <br />(SEE '<OTE / <br /> <br /> <br />/ <br />rnnir / - <br />~ ill!!:, <br />" l41 <br /> <br /> <br />~ EMBEDMEr'J\O'T r <br />1-1/4' MIN, <br /> <br />INSTALLATION ANCHOR <br />3J16K DIA. TAPPER <br />(NOTE 17) <br /> <br />CONCRETE DR <br />__ MASONRY OPENING <br />BY OTHERS <br /> <br />SHEA THING - <br />BY OTHERS <br /> <br />SHIM AS REfQ/D <br />(SEE NOTES> <br />CAULK BETwEEN <br />DOOR FLANGE <br />8. SHEA THING <br /> <br />N I /X\I <br /> <br />...., <br />I <br />- <br />~" <br /> <br />STUCCO <br />OR SIDING <br />BY OTHERS <br /> <br />PERIMETER ~ <br />CAULK BY <br />OTHERS <br /> <br />?, <br /> <br />I <br />i <br />~ <br /> <br />& <br />CAULKING AT FASTENER <br />HOLES REQUiRED <br />(SEE NOTE 2), <br /> <br />SLIDING GLASS <br />DOOR FRAME l <br />SILL <br />& \ <br />\ <br />1/4' MAX \ \ <br />SHIl-1 SPACE] .!JL, <br />~- <br /> <br />t .. ~ II <br /> <br />b <br /> <br />Hi <br />i ]11.. <br />IJ lIJh. <br /> <br />I> <br /> <br />.6 <br /> <br />A <br /> <br />IN~TALlATION ANCHOR <br />liS \"iOOD SCR.Ew w /PLASTIC <br />ANCHOR (TYP, wHERE <br />TAPPERS ARE NOT REQ'D, <br />~ SEE NOTE 20) -- <br /> <br /> <br />lIBERALLY APPLY CAULKING <br />UNDER SILL OR SET SIll IN <br />BED OF CONCRETE (SEE NOTE 2), <br />SHIM AS REQUIRED (SEE NOTE 1), <br /> <br />.. <br /> <br />It <br /> <br />DOOR <br />HEIGHT <br /> <br />w <br /> <br />~ ~ 00 0 <br />f-.(j) ~ ~ ~ <br />~z oZ: W < l.O...t 'A <br />(j) 0 0::: N l.O WI' <br />. oi=o O.-;'1t Z <br />O:::WZ~() "...w.... 0 <br />w<() w~l.OlJ.. <br />zf-IT:~ :r::r:~. i= <br />_ (j) - Z f- f- ..l LiJ :J <br />t:l IX S3 i3 0::: l.L. IJ. 0.. ....J <br />zWo...-J 00'.0 <br />WO(j):S(j)l.L.z~r5 (I) <br />wZ(j)cnZOO .0 <br />J::::)zwQ~i=ZO:: Z <br />f- 0 ::s :r: (j) <I: 0::: ==:J c,:, <br />6:'i0..f-:>wfrotn Rl <br />J: W (j) a::. .... <br />t:;w~f-O:::o-..Jca'" C <br />wgO:::3:0(Y')~~...:uj <br />cow:::J ....:::).....c:c < <br />W.....ll--~~Of-...t::c 0 <br />I~Ua.. wUO::U ~ <br />f-O~~2=Z~~i 0 <br />OZf-O-~f-DO ....J <br />f-~(j)()3:(j)(j) LL. <br /> <br />(J) <br />o <br />('I') <br />('\J z <br />g Q <br />..: C9 ~ <br />f- r'-- N <:t <br />E ~~~ 8 <br />o >(wo N <br />V)<l:w:r: <br />:g('l')l..l..~~ ..-I- <br />as 0 Lf) ~ <I: : <br />~~~6J6 ~ <br />C('I')-.L:::;!W .8 <br />CO-..J"f....f- u <br />(sl.L...-IO:::<I:..-IO <br />.C9:::J()(!) <br />e,rjcor'--t)D:..-! <br />-6.~:::Jf=0) w <br />..-I 0 0::: 0::: . f- <br />11) a:r: f- w 0 <I: <br />O"l <I: 0.. en () Z 0 <br /> <br />These notes are provkled to ensure proper installation of Florida Extruders Milestone products and must be followed fully, <br /> <br />GENERAL INSTA.LLATION INSTRUCTIONS <br /> <br />I Al <br />t <br />I ! 1& <br /> ;# ;# <br /> I <br /> fTl <br /> B I B <br /> I <br />I & A..-J & <br />. EXTERIOR ELEVA TIm,) <br /> 2 PANEL DOOR SHOwN <br /> (SEE NOTES 8) 9 8.: 10) <br /> <br />INSTALLATION ANCHOR <br />#8 wOOD SCREW' <br />(NOTE 21) <br /> <br />I[=~ ~ <br /> <br />r~"q 1-118' MIN,- <br />~ EMBEDMENT <br /> <br />l f l ~6~~IN~R~~~S~ <br /> <br />HEAD <br /> <br />1/2'.1 <br /> <br />, EMBEDMENT <br />i 1-114# MIN, <br /> <br />',-- TEMPERED <br />GLASS <br />CfYP,) <br /> <br />CAULKING & <br />REQUIRED _ <br />(SEE NOTE 2). <br /> <br />?'" <br /> <br />'!r <br /> <br />I <br /> <br />ll/~t <br /> <br />I T\o/O BY 'WOOD <br />BY OTHERS <br />(NOTE 6) <br />"Iv <br />/i\- A 1/4' MAX, <br /> <br />i \/ ! r SHIM SPPC( <br /> <br />~ <br /> <br /> <br />if.-.- <br /> <br />I <br />i <br />I <br />ii <br /> <br />.. <br /> <br />i:J <br /> <br />.1 <br /> <br />~ <br /> <br />Co <br /> <br />\0' <br /> <br />_ INST ALLA TIm~ M,JCHOR <br />3/16' DIA, TAPPER <br />(NOTE 15) <br /> <br />CONCRETE DR <br />-- MASONRY OPENING <br />B'( OTHERS <br /> <br />SECTION A-A <br /> <br />DOOR <br />HEIGHT <br /> <br />t <br /> <br />1) SHIM AS REQ'D. AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. MAX. ALLOWABLE SHIM STACK TO BE 1/4". <br />LOAD BEARING SHIM AT SILL MUST BE PRESSURE TREATED WOOD OR PlASTIC AND MUST BE COMPLETELY ENCAPSULATED IN <br />CAULKING OR SET lNTO WET CONCRETE. <br />2) USE SILICONIZED ACRYLIC CAULK BEHIND DOOR FLANGE AT HEAD & JAMBS. LIBERALLY APPLY SILICONIZED ACRYLIC <br />CAULKING UNDER SILL OR SET SILL IN BED OF WET CONCRETE, CAULK BETWEEN BACK CORNER OF SILL RISER AND <br />CONCRETE, CAULK ALL FASTENER HOLES PRlOR TO INSTALUNG FASTENER AND AROUND HEAD AFTER INSTALLATION. <br />3) USE SILICONIZED ACRYLIC CAULK FOR PERIMETER SEAL AROUND EXTERlOR OF DOOR AND BET\^IEEN HOOK STRIP & BUCK <br />fOR POCKET DOORS, <br />4) JAMB AND SILL CORNERS ARE TO BE SEALED WITH A SMALL JOINT SEAM SEALER. <br />5) DOOR FRAME MATERIAL: ALU~"INUM ALLOY 6063. <br />6) TWO BY WOOD BUCK AND/OR FRAMING AT THE HooKSTRIP TO BE SECURELY FASTENED TO TRANSFER THE LOAD TO THE <br />MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE PER FBC; SECTION 1707.4.42 AND THE ENGINEER OF RECORD'S <br />DETAilS. <br />7) FLORIDA EXTRUDERS 1000 SERIES SLIDING GLASS DOOR IS SHOWN, THIS PRINT ALSO APPLIES TO THE FLORIDA <br />EXTRUDERS 500 AND 2000 SERIES SllDING GlASS DOORS. <br />8) WHERE "X" REPRESENTS MOVING PANEL AND "0" REPRESENTS FIXED PANEL, APPROVED CONFIGURATIONS ARE AS LISTED <br />ON THE ANCHOR INSTALLATION CHART. <br /> <br /> 0 <br /> 0 <br /> Z \J) <br /> 0 w <br /> - r- <br /> rn - 0 <br /> - :J oQ' <br /> > rn t' <br /> - .... <br /> (J . l' <br /> 0 .... <br /> > I N <br />. <t -l 0\ III <br />(] ID 0 I <br /> - \J) en <br /> ~ w ['ll \J) <br /> 0 ~ [Y] l' <br /> ...J 0 I <br /> I.L. I ..J M <br /> U1 I.&. .... <br /> ...J r- ~ OJ <br /> ~ U1 D. I <br /> r! w ,... <br /> ~ ~ <br /> I- ~ <br /> Z . I- <br /> W Z <br /> (J 0 <br /> 0 <br /> IJ) <br /> 0 <br /> z W <br /> c.:l Z <br /> C7i~~ 0 <br /> LWf-(/)W:J <br /> oz(/):::!<:( <br /> DO-I> <br /> z~t::$:(/) <br /> <:C\lWo:::~ <br /> c.:lM~OO <br /> zo:::ooO <br /> ~t2wwu <br /> ~O~~~ <br /> 0:J0:::(/)1l! <br /> 'fl~b:OO::: <br /> ~'fl<:~B <br /> <br />C'-< <br />..., <br />We-- <br />o:~ <br />~o <br />::>2 <br />5t:l <br />~Q <br />.u <br />"'>:J <br />~?t <br />~~ <br /> <br />,:~,,/,,(,.,l>;~IS;';';\':~t.~" ~I,. ;"';,t..' '.~ <br />..;to- %f r..j~a~J.!..' '. <br />oJ;' ;e...,'~t,,,,.,.'rt~~l:r,; <br />rj/ ' ..,~ ~i1"\ <br />t, ,., \ <br />I()"'" /, .'4,:' \ <br />4-:l: . ~ !l' :l <br />ifl.' ,'~ ~,,,~.,.t,~~ <br />.~.". 't'.."", "WNN;:'_~.~2~' r.p..,"( <br />',$ "".&%2 J . > ."..; J <br />~ ' ~1tW- f" ';t' <' <br />'f,. ,.',>', ,.~.~;. : <br />". '~"f ,~...,ar. 'i/l);f' : <br />J t. ~~: w..vt,:~'1;. ~ ;,: <br />kj,: .;fit. ,~"-~":,,,~,,,,""', .~"'~ <br />'; '" i$.'tifY#~ %.://~ <br />~ '';''~,/,::,,~' ~:~::<~.,,\ ~~ <br /> <br />[SEE SHEET 2 FOR CONTINUATION OF NOTES] <br /> <br />REV DESCRIPTION DATE INI FLORIDA EXTRUDERS INTERNATIONAL, INC <br />B REVISED NOTES 1, 2, 3, 6, 112/18/03 RJA ~ 2540 JEWETT LANE <br />11, 12, 13, 16,22, 23 & I ' CE.RTIFICATE OF AUTHORiZATION NO 9235 SANFORD. F'LORIDA <br />~tv~~g ~~~fEtND/OR I I TITLE: SLIDING GLASS DOOR 500; 1000 2x 2000 <br />RE.:FERENCES AND/OR I MASONRY INSTALLATION \.;ITH f\iON-STRUCTURAL <br />~6~i~~T!f~Sio R;~gM6ERED BUCK A~lD TAPPERS <br />REVISED REFERENCES TO DRAWN BY' BB APPROVED BY: RJA <br />THt.'SE NOTES REVISED ' <br />~~:i'.~tt ~~~R~OXX I DATE: j? 118/03 I SCALE: NTS DWG #: FLEX0021 SHEET 1 OF 2 <br /> <br />FRAME INSTALLATION <br /> <br />-DOOR 'dIDTH ~-l: 1/4' MAX, SHIH SPACE <br /> <br />,__1-118 MIN, HiD BY wOOD BY ~) <br />EMBEDMENT OTHERS (NOTE 6) ~ / <br />SLIDING GLASS / <br />DOOR FRAHE ~ \', <br />.JAMB \ /JC= HID BY wOOD LNSTALLATlON ANCHOR \' <br />\ \ BY OTHEoS; #8 wOOD SCREw OYP,) \ <br />'-- n I~ (NOTE 6) (~IOTE 21> I <br />..r=r?' (ANCHORS SHO\JN IN SAME <br />~ ~ I PLANE FOR CLARITY ONLY, <br />/ I HOOK STRIP ANCHOR HOLES \ <br />SPACED 2' APART ON <br />,..r- SHIM AS REQ'D. <br />17[: (SEE NOTES) <br />SLIDING GLASS DDoR~ ., / \ I (TYP) <br />HOOK STRIP ~ ~ 1 <br /> <br />\ -L <br />/~ INSTALLATION ANCHOR ~ '1 /1' \ .1,(~' "~" ~03/4' <br />-- #8 \.;OOD SCREw .'" .., .> " <br />\ (NOTE 21> I' , "'" ",""--... - <br /> <br />\ CAULK BET\.JEEN TO'\PERE~D ~= L I <br />DOOR FLANGE GLASS CTYP,) 1l~ <br />\ 8. SHEA THING D SHEA THING <br />. ~ BY OTHERS <br /> <br />~ SHEATHING ~ "--f~ig~~~c~LASS DOOR <br />BY OTHERS HOD K S T RIP DE T A I L <br /> <br />CAULK BET\./EEN <br />HoOI< STRIP 8, <br />'NOOD BUCi< <br /> <br />" <br />~'. <br /> <br />=cd.C <br />III <br />,I ~~ <br /> <br />i TEMPERED <br /> <br />u <br /> <br />s <br /> <br />NAX, <br /> <br />('\l(/) <br />L!)Z <br />('\lO <br />.,(/) <br />> <br />w <br />n::: <br /> <br />CTYP,) <br /> <br />;J <br /> <br />GLASl <br />I <br /> <br />~'(, <br /> <br />PERIMETER <br />CAULK BY <br />OTHERS <br /> <br />STUCCO <br />OR SIDING <br />BY OTHERS IMPORTANT INFORMATION & GENERAL NOTES <br />These notes are provided to ensure proper installation of Florida Extruders Milestone produds and must be <br />followed fully. <br /> <br />lLJ ~ <br />0 <br /> 0::: <br />() >-l.L.Z <br />zf-O <br />- ~z- <br />I- Z:W~ <br />-en> <br />0 oZo <br />~o<l: <br />Z :::)()o <br />oz- <br /> oWO:: <br />I- 0:::1-0 <br />o..!:::U:: <br />I wO:::.-J <br />0:::3:<1: <br />(!) wwO::: <br />CO:r:f- <br />- I-I-~ <br />Of-() <br />0:: z:::;) , <br />>-00.. <br />>- <t::r:o:: <br />~f-o <br />0... 3:() <br />z <br />::so:::w <br />0 w~ <br />o..zo <br />() enz:r: <br />-<l:(j) <br /> 2=~:::J <br /> <br />SECTION B-B <br /> <br />#f <br />L <br /> <br />AI <br />I I <br />i <br />I <br /> <br />1) SHIM AS REQ'D. AT EACH INSTALLATION ANCHOR WITH LOAD BEARlNG SHIM. MAX. ALLOWABLE SHIM STACK TO <br />&, BE 1/4". LOAD BEARING SHIM AT SILL HUST BE PRESSURE TREATED WOOD OR PLASTIC AND MUST BE COMPLETELY <br />ENCAPSULATED IN CAULKING OR SET INTO WET CONCRETE, <br />. 2) USE SILICONIZED ACRYLIC CAULK BEHIND DOOR FLANGE AT HEAD & JAMBS. LIBERALLY APPLY SILICONIZED <br />B ACRYLIC CAULKING UNDER SILL OR SET SILL IN BED OF WET CONCRETE. CAULK BETWEEN BACK CORNER OF SILL <br />1;", RISER AND CONCRETE. CAULK ALL FASTENER HOLES PRIOR TO INSTALLING FASTENER AND AROUND HEAD AFTER <br />@ INSTALLATION. <br />3) USE SILICONIZED ACRYLIC CAULK FOR PERIMETER SEAL AROUND EXTERIOR OF DOOR AND BETWEEN HOOK STRIP <br />& BUCK FOR POCKET DOORS, <br />4) JAMB AND SILL CORNERS ARE TO BE SEALED WITH A SMALL JOINT SEAM SEALER, <br />5) DOOR FRAME f>1ATERlAL: ALUMINUM ALLOY 6063. <br />J.'\ 6) roo BY WOOD BUCK AND/OR FRAMING AT THE HEAD, JAMB AND HOOKSTRIP TO BE SECURELY FASTENED TO <br />ill TRANSFER THE LOAD TO THE WOOD OR APPROVED FRAMING MEMBERS PER me, SECTION 1707A.4.3 AND THE <br />ENGINEER OF RECORD'S DETAILS, <br /> <br />SHEET NO. <br /> <br />0.. <br />0::: <br />o <br />() <br />W <br />~ <br />o <br />:r: <br />(j) <br />:::) <br />('I') <br />o <br />o <br />('\J <br />@ <br /> <br />GENERAL INSTAL1.AT10N INSTRUcl10NS <br /> <br />U) <br />-1 <br /> <br />- <br /> <br /><( <br />I- <br />W <br />o <br /> <br />#f <br /> <br />, <br />B <br /> <br />I <br />A-J <br />& EXTERIOR ELEVATION <br />2 PANEL DOOR SHOWN <br />(SEE NOTES 8, 9 8.: 10) <br /> <br />w <br />~ <br />c:t: <br />Z <br />Z <br />c:t: <br />......J <br />n.. <br /> <br />~ <br /> <br />N <br />.lO <br />w.Jt"<- <br />a:~ <br />go <br />::>z <br />f5b5 <br />~E5 <br />.V <br />"?:J <br />ffi~ <br />g5::; <br />0::. "- <br /> <br />,;;.j;'<'t:Ji:"/';:~>"";"'>' ~ "'. .~, . ;.. ~ <br />,;:- ,}. ~j;ifi$.Jt~' '. <br />cr,;"" ~(F*~;t'l(,.. rl:Yn~', <br />i".~:~lR ,~r. ~ - ~,- ;Ji; , ~-~ <br />t ~ ;/' :~ ~i> ;,1 <br />:ty~..., ".'" ~i' 1&, (, <br />~ '~/i '~' , $81' '.~ ~ <br />: ? ... ' ,;.J"{& ~ __m.A" ,.-.H" <br />? ~ ~~, _ ~ , ~-t-~~~'r~~ <br />\ t ~t(, , ~Zf~'> {oJ <br /> <br />\,. #~;~>>~"" . '~; <br />,;.v;. " " <br />'. <br />" <br /> <br />[SEE SHEET 2 FOR CONTINUATION OF NOTES] <br /> <br />FLORIDA E,xrrRU' DERS INTERNATIONAL, INC. <br />1 f 2540 JEWETT LANE <br />CERTIFiCATE OF AUTHOR'ZATION NO. 9235 SAN FO RD , FLO RIDA <br />TITLE: SLIDING GLASS DOOR 500, 1000 8< 2000 <br />FRAME INSTAl_LATION \v'ITH #8 SCREv';S <br /> <br />REV DESCRIPTION DATE INI <br />B <br /> <br />8-15 <br /> <br />REYlSED NOTES 1,2.3,6, 11, 1;:>/18/0"'I.RJA <br />20, 25 & JD N.O ADDED - '" <br />A,~ D / OR REVISED R€LA TED I <br />REFEReNCES ANO/OR I <br />ILLJJSTRAT10NS. ADDED NOTE I <br />20 AND RELATED <br />ILLUSTRA110NS.. RENUMBERED <br />NOTES 6 TO l 0 '" ,,1 TO 2 9 <br />MD REVISED REfERENCES TO <br />Te! ESE NOTES, Rt:VlstD <br />TAPPERS fOR 90XX 3-PANEL <br />DOORS. <br /> <br />LAST PLOT DATE <br />October 11, 2004 <br /> <br />APPROVED BY: RJI; <br />NTS IDWG .#: FLEXOD27 SHT 1 OF 2 <br /> <br />'~ y .~ " 'i ..0- '" '" <br /> <br />DRAWN BY: BB <br />PATE: 12/18/03 <br /> <br />~ ~; " /'.~ '~, <br />,. ~'\~"{>:h..~",;; ~ ,,..'~:~~,,~~<.':....:" ". <br /> <br />ISCALE: <br /> <br />SGD INSTALLATION <br />INSTRUCTIONS (MILESTONE) <br /> <br />--.----- <br /> <br />-.----.---.. -_..,--.-..--~._--' --.----- <br />