Laserfiche WebLink
<br />l!) <br />o <br />o <br />'N <br />~1-1 <br />OU . <br />>-~O <br />f-OW <br />Cl::~!:: <br />wa.CO <br />o...(/lI <br />0-0 <br />~:x:~ <br />a.f-a. <br />~5~ <br />Of-W <br />....Z(/l <br />wW::J <br />I--'O <br />f-Uw <br />WWN <br />O:::X:- <br /><(f-i5 <br />(/lOI <br />ZZf- <br />~<(::J <br />V5u<( <br />W-,Z <br />o....J::J <br />od:l:: <br />zzo <br /><(-z <br />(/lffiQ <br />~Wf- <br />zzU <br />--::J <br />~~o <br />~w~ <br />DCa. <br />WUW <br />(/l(/lO:: <br />WZ>- <br />~t3~ <br />C0 <br /> <br />STRUCTURAL NOTES: <br /> <br />GENERAL NOTES: <br /> <br />TERMITE SPECIFICATIONS: <br /> <br />STRUCTURAL DESIGN CRITERIA <br /> <br />() NCO <br />--.J ro 0) <br />--.J M (D <br />Mm <br />,(1) <br />'-' c:( ~ <br />Z 9~ <br />o - 0::: 10 <br />() 0::: 0 ~ <br />(j) W u:~ <br />W " <br />Zz I~ <br /><( - Uu..; <br />O(!)L5 <br />Zco <br />w g~~ <br />~6aO) <br />0..(1)11) <br /><(~N <br />'(Dc:( <br />O.......U <br />OM <br /> <br /> <br /> <br />Q~g <br />X, <br />OI.JJ <br />COz <br />'0 <br />~::r: <br />0...0.. <br /> <br />W <br />:20= <br />w' ~ ii it <br />W f-wl.L.1- <br />U <(O:2:Z <br />:2-0::J <br />I- XClla::O <br />O 0~l.L.() <br />a::OZ~ <br />Z 8::2~1- <br /><(0<(0 <br />W wO=f-Z <br />a::l.L.w <br />'-' <(Z0=8 <br />- Ow<( <br />........ w~",O <br />I- f- <( ~, Z <br />O Of-~<( <br />::Jw-w <br />o <Y 0= CIl :2 <br />Ll.. CIl <( tE ~ . <br />wcll"", Z <br />l:lZ~ 0 <br />W ~QOo~ <br />0:: OCllo::f-() <br />- otEQ~:J <br />........ iL a:: () n. <br />:::> w~~g~ <br />o ~OZClJ-I <br />U) g,::::J-.a::;;i <br />cIl~~~~ <br />w....Jo:>- <br />::::J>~ZO:: <br /><(O:>~O <br /> <br />FOUNDATIONS <br />SOIL TO BE COMPACTED TO AT LEAST 95% <br />OF MAX. DRY DENSITY AS DETERMINED BY <br />ASTM - 1557 ( MODIFIED PROCTOR) <br />FOUNDATION INSPECTIONS <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A <br />COpy OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING <br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE <br />EXPOSED AND A STRING STRECHED FROM MARKER TO <br />MARKER TO VERIFY REQUIRED SETBACKS. <br />CAST IN PLACE CONCRETE <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS OF 3000 PSI, A SLUMP OF 6" <br />PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, <br />AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC <br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 <br />GRADE 40. <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185, <br />WWF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT <br />LEAST ONE CROSS WIRE WITHIN THE 6". <br />4. HOOKS SHALL BE PROVIDED AT DiSCONTINUOUS ENDS OF <br />ALL TOP BARS OF BEAMS. <br />5. HORIZONTAL FOOTING BARS SHALL BE BENT 1'-0" <br />AROUND CORNERS OR CORNER BARS WITH A 2'-0" <br />LAP PROVIDED <br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR <br />SPLICES SHALL BE 40 BAR DIAMETERS TYP. <br />7. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR <br />11/2" TO FORM <br />MASONRY WALL CONST. <br />1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL <br />WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90, <br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF <br />1900 PSI ( f'm = 1500 PSI) <br />2. MORTAR SHALL BE TYPE "M" OR "S", CONFORMING TO <br />ASTM C270. <br />3. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM <br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11". <br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE <br />DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. <br />5. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION <br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING <br />OF 192 BAR DIAMETERS. REINFORCEMENT SHALL BE PLACED <br />IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS <br />OTHERWiSE NOTED. <br />6. REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 40 BAR <br />DIAMETERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />7. DUR.{)-WALL SHALL BE PROVIDED @ EVERY OTHER <br />COARSE OR 16" O/C <br /> <br />FLORIDA BUILDING CODE, 2001 EDITION <br />BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02) <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-89) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02) <br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION <br />APA PLYWOOD DESIGN SPECIFICATION <br /> <br />CODES: <br /> <br />1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE-INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL <br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL.(FBC 104.2.6) <br /> <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" <br />AWAY FROM BUILDING SIDE WALKS,(FBC 1503.4.4) <br /> <br />3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS <br />SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS.(FBC 1503.4.4) <br /> <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BElVIEEN WALL <br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 INCHES, <br /> <br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5/8" <br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL,(FBC 1403,1.6) <br /> <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFlLL <br />IS COMPLETE,(FBC 1816.1.1) <br /> <br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED AND FORMED,(FBC 1816,1.2) <br /> <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, <br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT <br />FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF <br />SOIL AFTER THE INITIAL TREATMENT.(FBC 1816.1.3) <br /> <br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS <br />REQUIRED.(FBC 1816,1.4) <br /> <br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT.(FBC 1816.1.5) <br /> <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS,(FBC 1816,1.6) <br /> <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION, ANY SOIL DISTURBED AFTER <br />THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED.(FBC 1816.1.6) <br /> <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE-CONSTRUCTION TREATMENT.(FBC 1816.1.7) <br /> <br />13. A CERTIFICATE OF COMPLIANCE MUST BE iSSUED TO THE BUILDING DEPARTMENT <br />BY A LICENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY <br />WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES, THE TREATMENT is IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />FLORIDA DEPARMENT OF AGRICULTURE AND CONSUMER SERVICES."(FBC 1816,1.7) <br /> <br />14. AFTER ALL WORK is COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'.{)" OF THE BUILDING. THiS INCLUDES ALL GRADE STAKES, <br />TUB TRAY BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />(FBC 2303.1.3) <br /> <br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHALL BE BURIED <br />WITHIN 15'-0": OF ANY BUILDING OR PROPOSED BUILDING,(FBC 2303,1.4) <br /> <br />PREFABRICATED WOOD TRUSSES <br /> <br />1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY <br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH <br />HURRICANE CLIPS OR ANCHORS. <br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED IN <br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL <br />DESIGN SPECIFICATION FOR STRESS-GRADE LUMBER AND <br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL <br />FOREST PRODUCTS ASSOCIATION. <br />3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPOR- <br />TIONED ( WITH A MAXIMUM ALLOWABLE STRESS INCREASE <br />FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE <br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD, <br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS <br />REQUIRED BY THE TRUSS MANUFACTURER UNLESS <br />NOTED ON THE PLANS. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL <br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE <br />NOT SHOWN, BUT SHALL BE DESIGNED BY THE TRUSS <br />MANUFACTURER IN ACCORDANCE WITH THE DESIGN <br />LOADS AS LISTED ON THE STRUCTURAL DESIGN CRITERIA <br />6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL <br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS <br />PLATE INSTITUTE TPI LATEST EDITION. <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY <br />THE MANUFACTURER IN ACCORDANCE WITH SPECIFlED LOADS <br />AND GOVERNING CODES. SUBMITTALS SHALL INCLUDE TRUSS <br />FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, <br />BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, AND <br />AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED <br />FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH <br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA <br />REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS <br />WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. <br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL <br />BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br /> <br />THE FOLLOWING TECHINCAL CODES <br />SHALL APPLY: <br /> <br />2001 flORIDA BUILDING CODE, <br />PLUMBING, MECHANICAL, FUEL GAS, <br />ENERGY EFFICIENCY, ACCESSIBILITY, <br />AND 2002 NATIONAL ELECTRICAL CODES <br /> <br />ROOF <br />TOP CHORD <br />BOTTOM CHORD (W/O STORAGE) <br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED <br />BALCONIES <br />STAIRS <br /> <br />ROOF <br />FLOOR <br /> <br />WIND LOADS BASED ON FBC, SECTION 1606.2. <br />WIND VELOCITY: 120 M.P.H., USE FACTOR: 1.0 <br /> <br />ALL CONCRETE UNLESS OTHERWISE INDICATED <br />PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY <br />(DO NOT USE FOR CONCRETE COLUMNS OR TIE BEAMS) <br /> <br />LIVE LOADS: <br /> <br />20 PSF <br />10 PSF <br />40 PSF <br />40 PSF <br />40 PSF <br /> <br />17 PSF (SHINGLE) <br />15 PSF <br /> <br />ORDINANCE 92-19 - APPENDIX "J" <br />TO FBC PLUMBING 2001 CODE, <br />1. TANK TYPE WATER CLOSET VOLUME <br />1.6 GALLONS <br />2. WALL MOUNT WATER CLOSET VOLUME <br />3.5 GALLONS <br />3. WATER - FLOW RATE. <br />PUBLIC FACILITIES 0.5 G.P.M. <br />PRIVATE FACILITIES 2.2 G.P.M. <br />SHOWER HEADS 2.5 G.P.M, <br />4. ALL PLUMBING WATER LINES <br />TO BE PVPC <br /> <br />VTR LOCATIONS ARE APPROXIMATE <br />AND MAY CHANGE DUE TO JOBSITE <br />CONDITIONS <br /> <br />THE FOLLOWING SHALL COMPLY <br />WITH THE 2001 FBC. <br /> <br />o PORCHES AND BALCONIES <br />SECTION 1014 <br />o HANDRAILS - SECTION 1007.5 <br />o GUARDRAILS - SECTION 1015, 1019.9 <br />o STAIRS - SECTiON 1007 <br />o CHIMNEY & FIREPLACE <br />SECTION 2804-2806 (MFGR) <br />SECTION 2113-2114 (MAS) <br />o EGRESS WINDOWS <br />SECTION 1005.4 <br /> <br />DEAD LOADS: <br /> <br />WIND LOADS: <br />(F.B.C.) <br /> <br />3000 PSI <br />3000 PSI <br /> <br />CONCRETE <br />STRENGTH <br />@ 28 DAYS <br /> <br />10 <br />o <br />o <br />~ (j) <br />N Z <br />-rl 0 <br />~ <br />I.JJ (j) <br />~ > <br />o W <br />~ 0:: <br />(f) <br />(f) <br /> <br />o <br />. <br />-rf <br />Z <br />o <br />(j) <br />0::: <br />w <br />> <br /> <br />ASTM A185 <br />ASTM A615-40 40,000 PSI <br />ASTM A615-40 40,000 PSI <br /> <br />WELDED WIRE FABRIC SHALL CONFORM TO <br />ALL REINFORCING BARS <br />ALL STIRRUPS AND TIES <br /> <br />ASTM C90 OR C129, STANDARD WEIGHT UNITS, fm=1500 PSI <br />MORTAR TYPE "S" 1900 PSI <br />CONCRETE GROUT 3000 PSI <br />CONTINUOUS MASONRY INSPECTION IS REQUIRED DURING CONSTRUCTION <br /> <br />ALL STRUCTURAL AND MISCELLANEOUS STEEL A36 36,000 PSI, U.N.O <br />SHOP AND FIELD WELDS: E70XX ELECTRODES <br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 <br /> <br />REINFORCING: <br /> <br />CONCRETE <br />MASONRY <br />UNITS: <br /> <br />L.[) 00 C\/ <br />--t L.[) c\/ <br />N t-- ~ <br />.q- Q) 0 <br />(1) <;j- <.0 <br />w W l.LJ <br />a.: a.. 0..: <br /> <br />STRUCTURAL <br />STEEL: <br /> <br /> <br />BEAMS, RAFTERS, JOIST, PLATES, ETC. U.N.O. <br />NO.2 SOUTHERN YELLOW PINE (19% M.C.) <br />ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR, or OSB <br />FLOOR SHEATHING: 3/4" PLYWOOD (5 PLIES) OR 3/4" T&G ADVANTECH <br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />VERSA LAM BEAM Fb = 2900 PSI (2.0E) <br /> <br />WOOD FRAMING: <br /> <br />~ <br />Q) <br />.0 <br />C <br />~ C .L: <br />.... 0 c <br />~ en >.. <br />C :J <br />c:( &S I <br />Q) , I <br />:J >.. <br />~~ .~ .2 <br />_ I- <br /> <br />DD <br /> <br />4. ALL OPENINGS SHALL COMPLY WITH <br />2001 FBC WIND LOADS AS STATED <br />BELOW. ATTACHMENTS OF WINDOWS, <br />DOORS, SLIDING GLASS DOORS <br />AND O.H. GARAGE DOORS ARE TO DELEGATED <br />THE MANUFACTURER OF THESE ITEMS. THE <br />MANUFACTURER OF THESE ITEMS <br />SHALL SUBMIT ATTACHMENTS FOR <br />SITE INSTALLATION. <br /> <br />SEE ATTACHED SPECIFICATION SHEETS FOR <br />MANUFACTURERS DESIGN CRITERIA AND <br />INSTALLATION METHODS FOR WINDOWS, <br />DOORS, SLIDING GLASS DOORS, OVERHEAD <br />GARAGE DOORS, AND ROOFING. <br /> <br />UPLIFT CONNECTORS <br /> <br />DESIGN LOADS: <br />TOP CHORD LIVE AND DEAD LOAD: <br />BOTTOM CHORD LIVE AND DEAD LOAD: <br />TOTAL: <br /> <br />WOOD ROOF <br />TRUSSES: <br /> <br />27 PSF <br />20 PSF <br />47 PSF <br /> <br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS <br />ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON <br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES. <br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED <br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD <br />NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE CONSULT <br />THE TRUSS ENGINEERING FOR THE LOCATION OF THESE WALLS. <br /> <br />NET UPLIFT DESIGN PRESSURE: 20 PSF WITHIN <br />4 FEET OF RIDGES, HIPS, EAVES AND BUILDING <br />PERIMETER AND 15 PSF MIN FOR ALL OTHER AREAS. <br /> <br />SEE DRAWINGS FOR SPECIAL CONCENTRATED LOADS. DESIGN <br />FOR NEW WIND UPLIFT AS PER SPECIFIED CODES, DEDUCTING <br />A MAXIMUM OF 10 P.S.F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL <br />DEAD LOAD. <br /> <br />DESIGN LOADS: <br />DEAD LOAD: <br />LIVE LOAD: <br />TOTAL: <br /> <br /> <br />WOOD CONSTRUCTION <br /> <br />1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA <br />"NATIONAL DESIGN SPECIFlCATION FOR WOOD 1. MISSED LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY <br />CONSTRUCTION", 2001 EDITION, BE SUBSTITUTED W/ (1) "SIMPSON MTSM16lV11ST STRAP W/ <br />2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR (4) 1/4" X 2 1/4" DIA. TITENS TO THE BOND BEAM BLOCK <br />WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS, AND (7) 10d TO THE TRUSS FOR UPLIFTS OF 1000 LBS. OR <br />( I.E. BLOCKING OR GABLE END BRACING) SHALL BE EITHER LESS. USE (2) FOR 2000 LBS. OR LESS. OTHERS MAY BE <br />SOUTHERN PINE, OR S.P.F. NUMBER 2 GRADE SHALL BE SUBSTITUTED ON A CASE BY CASE BASIS, <br />USED REGARDLESS OF SPECIES. 2. MISSED "J" BOLTS FOR WOOD BEARING WALLS MAY BE SUB- <br />3. ANY WOOD FRAME BEARING WALL STUDS THAT ARE CUT STITUTED W/ 1/2" DIA. ANCHOR BOLTS SET IN 3/4" DIA. X 6" <br />FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH DEEP UNITEX "PROPOXY" 300 ADHESIVE BINDER FOLLOWING <br />SIMPSON HSS2 STUD SHOES,TYP., U,N.O. ALL MANUFACTURERS RECOMMENDATIONS ( OR 1/2" X 6" <br />4. ALL STUCCO FINISH OVER EXTERIOR FRAME MUST BE 7/8" THICK RAWL STUD EXPANSION ANCHORS, ) <br />PER ASTM C. 926-APPLY 3 LAYERS WITH TOTAL THICKNESS 7/8" 3. REGARDING MISSED REBAR IN VERTICAL FlLLED CELLS: <br />OVER METAL LATH. DRILL A 3/4" DIAMETER HOLE 6" DEEP AT THE LOCATION OF <br />FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. THE OMITTED REBAR, AND INSTALL A 32" LONG #5 BAR INTO <br />5. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH THE EPOXY FILLED HOLE. USE A lVIO PART EMBEDDEMENT <br />EARTH OR CONCRETE TO BE PRESSURE TREATED, EPOXY (SIMPSON "EPOXY TIE SET", OR HILTI " 2 PART" <br />EMBEDDMENT EPOXY), MIXED PER MANUFACTURER'S <br />*ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM <br />AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE DRILLING ARE REMOVED FROM THE HOLE BY BRUSHING AND <br />(CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR AND USING COMPRESSED AIR PRIOR TO APPLYING THE EPOXY. <br />GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED ALLOW THE EPOXY TO CURE TO MANUFACTURER'S SPECIFICATIONS, <br />WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. THEN FILL THE CELL IN THE NORMAL WAY DURING BOND BEAM <br />MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS POUR. <br />THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S 4. HURRICANE STRAPS MAY BE SUBSTITUTED WITH A STRAP OF <br />RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO GREATER HOLDOWN VALUE OR GREATER UPLIFT VALUE IN THE <br />SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. FIELD WITHOUT VERIFlCATION, PROVIDED ALL MANUFACTURERS <br />FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT-DIPPED INSTALLATION INSTRUCTIONS ARE FOLLOWED. <br />GALVANIZED OR STAINLESS STEEL FASTENERS. 5. FOR MORTAR JOINTS LESS THAN 1/4", PROVIDE (1) #5 VERT. <br />DOT SODIUM BORATE (SBX) DOES NOT. IN CONC. FILLED CELL EACH SIDE OF THE JOINT ( BAR DOES <br />WOOD FRAMING INSPECTION NOT HAVE TO BE CONT, TO FOOTING) <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL <br />ROUGH-INS MUST BE COMPLETE, INSPECTED <br />AND APPROVED BEFORE REQUESTING FRAMING <br />INSPECTION. <br /> <br />o <br />'<t <br />,... <br />,... <br />, <br />0') <br />o <br /><DI"- <br />("')1"- <br />("')N <br />-Jl/) <br />ll..d, <br />c{~ <br />0..' <br />~~ <br />~~ <br /> <br />FIELD REPAIR NOTES <br /> <br />WOOD FLOOR <br />TRUSSES: <br /> <br />5. ALL DOORS INTERIOR & EXTERIOR ARE <br />6'-8" UNLESS OTHERWISE NOTED <br />ALL SHOWER ENCLOSURES TO BE <br />TEMPERED GLASS <br />6. ALL WINDOWS WITHIN 24" OF DOORS <br />(INTERIOR & EXTERIOR) AND WITHIN <br />18" OF FLR TO BE TEMPERED GLASS, <br />(SECTION 2405.2) <br /> <br />15 PSF <br />40 PSF <br />55 PSF <br /> <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF <br />SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS <br />IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY <br />THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO <br />FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. <br /> <br />SOIL BEARING <br />VALUE: <br /> <br />ALLWORKSHALLCOMPLYWl11IALL .~ <br />PREVAILlNG CODES, FLORlDABU1LUIN J <br />CODE NATIONAL ELECTRIC CODE AND <br />cny OF ZEPHYRlllLLS ORDINANCES <br /> <br />INDEX OF DRAWINGS <br /> <br />BUILDING DATA <br /> <br />SHT NO: <br /> <br />TITLE <br /> <br /> z <br /> o. <br /> -0 <br /> ~> <br /> >-J <br /> -co <br /> Ow <br /> q:et: <br /> go <br /> et:I <br /> (f) g~ <br /> ll..(f) <br /> ...Jwo <br /> -.J ~~g <br /> I--ZW <br /> ....J ZoC: <br /> Wo::J <br /> - i()<D(f) <br /> I <br /> :r: <br />>- $ <br />L1.J <br />0::: - 0:::0... <br />> (V) I.JJO::: <br /> zO <br />0 0 ZO <br />~ <(I.JJ <br /> ~:2: <br />~ 0 W >-0 <br />(f) ZI <br />Z C\J u c:((f) <br /> ::J <br />L1.J z <br /> -:2: <br />L1.J 0 I- 00 <br /> I.JJO::: <br />0::: 0 uu.. <br />> a:: ::Jf- <br /> oz <br />() Z OI.JJ <br /> 0 O:::(f) <br />Z a..z <br /> ~ I.JJOZ <br /> LL Cl::oQ <br />- 0 I I.JJz~ <br /> >< COw> <br /> '-' f-~15 <br />~O w 0 0-<( <br />~ ZlYo <br />~~ 0::: >-3:- <br /><( <(wly <br /> :2:::r:g <br />Z >- zf-u.. <br /> Q.. :)f-...J <br />0 () Z ::)<( <br /> 0..00::: <br />5 0 (f)If- <br /> -I-Z <br />0 0 0.- U ::r:-w <br /> f-3:0 <br />I -.J HEET NO, a.. <br />N ly <br /> 0 <br />CO U <br />L() I.JJ <br /> A :2: <br /> 0 <br />I 00 ::r: <br />l"- (/) <br /> ::) <br />00 (1) <br />~ 0 <br /> 0 <br /> N <br />~ ~ LAST PLOT DATE @ <br />April 11, 2005 <br />L() 0 COVER SHEET <br />~ --I DE#250988 <br /> <br />CONSTRUCTION TYPE - TYPE VI UNPROTECTED <br />(SECTION 608 - FBC 2001) <br /> <br />WIND SPEED 120 MPH <br />WIND IMPORTANCE FACTOR - (Iw) = 1.0 <br />WIND EXPOSURE - "B" (FBC 1606.1.8) <br />INTERNAL PRESSURE COEFFICIENT = +1- 0,18 (ENCLOSED BLDG) <br /> <br />REVIEWED <br />MA~ 06 Z005 <br /> <br />A <br />1 <br />1A <br />2 <br />3 <br />4 <br />S-1 <br />8-2 <br />S-2A <br />S-3 <br />S-4 <br />S-6 <br />S-7 <br /> <br />COVER SHEET <br />FLOOR PLAN <br />DIMENSION FLOOR PLAN <br />STEM FOUNDATION PLAN <br />ELECTRICAL PLAN <br />ELEVATION PLAN (III) <br />STEM FOUNDATION DET. <br />LINTEL DETAILS <br />LINTEL PLANS <br />ROOF FRAMING (III) <br />GABLE DETAILS (III) <br />STEM WALL SECTIONS <br />STRUCTURAL NOTES & <br />HANGER INFORMATION <br />STRUCTURAL NOTES & <br />HANGER INFORMATION <br />WINDOW & DOOR DETAILS <br />ROOF INSTALLATION DET <br />ROOF INSTALLATION DET <br />MILESTONE WINDOW DET. <br />MILESTONE SGD DET. <br />STD. GARAGE DETAILS <br />FL PRODUCT APPROVAL <br /> <br /> <br />WIND BORNE DEBRIS AREAS <br /> <br />DESIGN WIND PRESSURE: <br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br /># END ZONE IS ONLY WITHIN 5'-0" <br />OF ALL EXTERIOR BUILDING CORNERS <br /> <br />~~ <br /> <br />WINDOWS AND DOORS <br />120 MPH + 25.9 PSF / - 34.7 PSF (END) <br />+ 25.9 PSF/-28.1 PSF (INTERIOR) U.N.O. <br /> <br />GARAGE DOORS (V = 120 MPH) <br />SINGLE 9x7 +25 PSF / -32.0 PSF <br />DOUBLE 16x7 +24 PSF / -24.5 PSF <br /> <br />SEE ELEVATION PAGE FOR ACTUAL PRESSURES <br /> <br />MASTER REVISIONS <br /> <br /> <br />S-7A <br /> <br />DESCRIPTION <br /> <br />DATE <br /> <br />S-8 <br />S-8.1 <br />S-8.1A <br />S-9M <br />S-10M <br />S-11 <br />SFPA <br /> <br />ENGINEERED PLANS <br />ON FILB <br /> <br />..............~..... ....... i ~. i .. .. !t"~ ~.;\ms... <br />1 I, .~". <br />",::' ~~.:;_~~':' :iii.D <br />. . . . I " ." l " '" t, .r: ," , . ;- ~ " <br />. ._. ." "-.. "i"" ,-,;., -'''Yk _:_,~z,:..-:J, <br /> <br />CENTRAL FLORIDA DIVISION <br />600 N. WESTSHORE BLVD. <br />SUrrE 600 <br /> <br />NOTICE TO BUILDER <br /> <br />TAMPA, FL 33609-1140 <br />1-813-769-5277 <br /> <br />IT is THE INTENT OF THiS DESIGNER THAT <br />THESE PLANS ARE ACCURATE AND ARE <br />CLEAR ENOUGH FOR THE LICENSED PROFESS- <br />ONAL TO CONSTRUCT THIS PROJECT, <br />IN THE EVENT THAT SOMETHING is UNCLEAR <br />OR NEEDS CLARIF1CATION..STOP..AND CALL <br />THE DESIGNER LISTED IN THIS TITLE PAGE. IT <br />is THE RESPONSIBILITY OF THE LICENSED <br />PROFESSIONAL THAT IS CONSTRUCTING THIS <br />PROJECT TO FULLY REVIEW THESE DOCUMENTS <br />BEFORE CONSTRUCTION BEGINS AND ANY AND <br />ALL CORRECTIONS, IF NEEDED, TO BE MADE <br />BEFORE ANY WORK IS DONE. <br /> <br />OXFORD 2003 <br />