<br />CONSTRUCTION lYPE -- lYPE VI UNPROTECTED <br />(SECTION 608 - FBC 2001) <br /> <br />WIND BORNE DEBRIS AREAS <br /> <br />THE METHOD TO SATISFY PROTECTION OF OPENINGS <br />IN THESE AREAS WILL BE THE SOLE RESPONSIBIUlY <br />OF TH E CONTRACTOR. <br /> <br />Termite Specifications: <br /> <br />Structural Notes: <br /> <br />1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER <br />AND NEED FOR RE.INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL <br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR <br />ELECTRIC PANEL.(FBC 104.2.6) <br /> <br />FOUNDATIONS <br />SOIL TO BE COMPACTED TO AT LEAST 95% <br />OF MAX. DRY DENSIlY AS DETERMINED BY <br />ASTM - 1557 ( MODIFIED PROCTOR) <br />FOUNDATION INSPECTIONS <br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A <br />COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING <br />INSPECTORS USE, OR ALL PROPERlY MARKERS SHALL BE <br />EXPOSED AND A STRING STRECHED FROM MARKER TO <br />MARKER TO VERIFY REQUIRED SETBACKS. <br />CAST IN PLACE CONCRETE <br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE <br />STRENGTH AT 28 DAYS OF 2500 PSI, A SLUMP OF 6" <br />PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT, <br />AND A MAXIMUM WATER/CEMENT RATIO OF 0.63 <br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC <br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615 <br />GRADE 40. <br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. <br />WNF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT <br />LEAST ONE CROSS WIRE WITHIN THE 6". <br />4. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF <br />ALL TOP BARS OF BEAMS. <br />5. HORIZONTAL FOOTING BARS SHALL BE BENT 1'-0" <br />AROUND CORNERS OR CORNER BARS WITH A 2'-0" <br />LAP PROVIDED <br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR <br />SPLICES SHALL BE 40 BAR DIAMETERS lYP. <br />7. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR <br />1 1/2" TO FORM <br />MASONRY WALL CONST. <br />1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL <br />WEIGHT, GRADE N, lYPE 2, CONFORMING TO ASTM C90, <br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF <br />1900 PSI (fm = 1500 PSI) <br />2. MORTAR SHALL BE lYPE "M" OR "S", CONFORMING TO <br />ASTM C270. <br />3. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A <br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM <br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11". <br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE <br />DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT. <br />5. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION <br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING <br />OF 192 BAR DIAMETERS. REINFORCEMENT SHALL BE PLACED <br />IN THE CENTER OF THE MASONRY CELL lYPlCAL UNLESS <br />OTHERWISE NOTED. <br />6. REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 40 BAR <br />DIAMETERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS <br />7. DUR-O-WALL SHALL BE PROVIDED @ EVERY OTHER <br />COARSE OR 16" O/C <br />WOOD CONSTRUCTION <br />1. WOOD CONSTRUCTION SHALL CONFORM TO THE NFPA <br />"NATIONAL DESIGN SPECIFICATION FOR WOOD <br />CONSTRUCTION", 2001 EDITION. <br />2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR <br />WALLS AND MISe. STRUCTURAL WOOD FRAMING MEMBERS, <br />( I.E. BLOCKING OR GABLE END BRACING) SHALL BE EITHER <br />SOUTHERN PINE, OR S.P.F. NUMBER 2 GRADE SHALL BE <br />USED REGARDLESS OF SPECIES. <br />3. ANY WOOD FRAME BEARING WALL STUDS THAT ARE CUT <br />FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH <br />SIMPSON HSS2 STUD SHOES,lYP., U.N.O. <br />4. ALL STUCCO FINISH OVER EXTERIOR FRAME MUST BE 7/8" THICK <br />PER ASTM C. 926-APPL Y 3 LAYERS WITH TOTAL THICKNESS 7/8" <br />OVER METAL LATH. <br />FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. <br />5. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH <br />EARTH OR CONCRETE TO BE PRESSURE TREATED. <br /> <br />*ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS <br />AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE <br />(CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR <br />GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED <br />WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-e. <br />MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS <br />THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S <br />RESPONSIBIUlY TO VERIFY THE lYPE OF WOOD TREATMENT AND TO <br />SELECT APPROPRIATE CONNECTORS THAT RESIST CORROSION. <br />FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT-DIPPED <br />GALVANIZED OR STAINLESS STEEL FASTENERS. <br />DOT SODIUM BORATE (SBX) DOES NOT. <br /> <br />SOIL BEARING <br />VALUE: <br /> <br />CODES: <br /> <br />PREFABRICATED WOOD TRUSSES <br /> <br />3, IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS <br />SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS.(FBC 1503.4.4) <br /> <br />1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY <br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH <br />HURRICANE CUPS OR ANCHORS. <br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED IN <br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL <br />DESIGN SPECIFICATION FOR STRESS-GRADE LUMBER AND <br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL <br />FOREST PRODUCTS ASSOCIATION. <br />3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPOR- <br />TIONED ( WITH A MAXIMUM ALLOWABLE STRESS INCREASE <br />FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE <br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD. <br />4. BRIDGING FOR PRE.ENGINEERED TRUSSES SHALL BE AS <br />REQUIRED BY THE TRUSS MANUFACTURER UNLESS <br />NOTED ON THE PLANS. <br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL <br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE <br />NOT SHOWN, BUT SHALL BE DESIGNED BY THE TRUSS <br />MANUFACTURER IN ACCORDANCE WITH THE DESIGN <br />LOADS AS USTED ON THE STRUCTURAL DESIGN CRITERIA <br />6. DESIGN SPECIFICATIONS FOR UGHT WEIGHT METAL <br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS <br />PLATE INSTITUTE TPI LATEST EDITION. <br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY <br />THE MANUFACTURER IN ACCORDANCE WITH SPECIFIED LOADS <br />AND GOVERNING CODES. SUBMITTALS SHALL INCLUDE TRUSS <br />FRAMING PLANS AND DETAILS SHOWING MEMBER SIZES, <br />BRACING, ANCHORAGE, CONNECTIONS, TRUSS LOCATIONS, AND <br />AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED <br />FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH <br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA <br />REGISTERED STRUCTURAL ENGINEER. SUBMIT 3 COPIES FOR <br />REVIEW AND APPROVAL PRIOR TO FABRICATION. <br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS <br />WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS. <br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL <br />BRACING MEMBERS, AND ALL TRUSS TO TRUSS HANGERS. <br /> <br />WOOD FRAMING: <br /> <br />2. CONDENSATE AND ROOF DOWNSPOUTS SHALL DISCHARGE AT LEAST 1'-0" <br />AWAY FROM BUILDING SIDE WALKS.(FBC 1503.4.4) <br /> <br />LIVE LOADS: <br /> <br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BElWEEN WALL <br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 INCHES. <br /> <br />DEAD LOADS: <br /> <br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5/8" <br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.(FBC 1403.1.6) <br /> <br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL <br />IS COMPLETE.(FBC 1816.1.1) <br /> <br />WIND LOADS: <br />(F. B.C.) <br />CONCRETE <br />STRENGTH <br />@ 28 DAYS <br /> <br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED <br />INCLUDING SPACES BOXED AND FORMED,(FBC 1816.1.2) <br /> <br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS, <br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT <br />FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DISTURBANCE OF <br />SOIL AFTER THE INITIAL TREATMENT.(FBC 1816.1,3) <br /> <br />REINFORCING: <br /> <br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTEl"'T AGAINST RAINFALL <br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT, RETREATMENT IS <br />REQUIRED,(FBC 1816,1.4) <br /> <br />CONCRETE <br />MASONRY <br />UNITS: <br /> <br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PER1METER MUST BE <br />REMOVED BEFORE EXTERIOR SOIL TREATMENT.(FBC 1816.1.5) <br /> <br />STRUCTURAL <br />STEEL: <br /> <br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE <br />WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS.(FBC 1816.1.6) <br /> <br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION <br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION. ANY SOIL DISTURBED AFTER <br />THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED.(FBC 1816,1.6) <br /> <br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE-CONSTRUCTION TREATMENT.(FBC 1816,1.7) <br /> <br />UPLIFT CONNECTORS <br /> <br />WOOD ROOF <br />TRUSSES: <br /> <br />13. A CERTIFICATE OF COMPUANCE MUST BE ISSUED TO THE BUILDING DEPARTMENT <br />BY A UCENSED PEST CONTROL COMPANY BEFORE A CERTIFICATE OF OCCUPANCY <br />WILL BE ISSUED. THE CERTIFICATE OF COMPUANCE SHALL STATE: "THE BUILDING <br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN <br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE <br />FLORIDA DEPARMENT OF AGRICULTURE AND CONSUMER SERVICES."(FBC 1816,1.7) <br /> <br />1. UPUFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS <br />ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON <br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES. <br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED <br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD <br />NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE CONSULT <br />THE TRUSS ENGINEERING FOR THE LOCATION OF THESE WALLS. <br /> <br />14. AFTER ALL WORK IS COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM <br />BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES, <br />TUB TRAY BOXES, FORMS, SHORING OR OTHER CELLULOSE CONTAINING MATERIAL. <br />(FBC 2303.1.3) <br /> <br />15, NO WOOD, VEGETATION, STUMPS, CARDBOARD, TRASH, ETC., SHflLL BE BURIED <br />WmiIN 15'-0": OF ANY BUILDING OR PROPOSED BUILDING.(FBC 2303.1.4) <br /> <br />FIELD REPAIR NOTES <br /> <br />WOOD FLOOR <br />TRUSSES: <br /> <br />WOOD FRAMING INSPECTION <br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL <br />ROUGH-INS MUST BE COMPLETE, INSPECTED <br />AND APPROVED BEFORE REQUESTING FRAMING <br />INSPECTION. <br /> <br />1. MISSED LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY <br />BE SUBSTITUTED W/ (1) "SIMPSON MTSM16lWIST STRAP W/ <br />(4) 1/4" X 2 1/4" DIA. TITENS TO THE BOND BEAM BLOCK <br />AND (7) lOd TO THE TRUSS FOR UPLIFTS OF 1000 LBS. OR <br />LESS. USE (2) FOR 2000 LBS. OR LESS. OTHERS MAY BE <br />SUBSTITUTED ON A CASE BY CASE BASIS. <br />2. MISSED "J" BOLTS FOR WOOD BEARING WALLS MAY BE SUB- <br />STITUTED W/ 1/2" DIA. ANCHOR BOLTS SET IN 3/4" DIA. X 6" <br />DEEP UNITEX "PROPOXY" 300 ADHESIVE BINDER FOLLOWING <br />ALL MANUFACTURERS RECOMMENDATIONS ( OR 1/2" X 6" <br />RAWL STUD EXPANSION ANCHORS. ) <br /> <br />3. REGARDING MISSED REBAR IN VERTICAL FILLED CELLS: <br />DRILL A 3/4" DIAMETER HOLE 6" DEEP AT THE LOCATION OF <br />THE OMITTED REBAR, AND INSTALL A 32" LONG #5 BAR INTO <br />THE EPOXY FILLED HOLE. USE A lWO PART EMBEDDEMENT <br />EPOXY ( SIMPSON "EPOXY TIE SEr', OR HIL TI " 2 PART" <br />EMBEDDMENT EPOXY ), MIXED PER MANUFACTURER'S <br />INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM <br />DRILUNG ARE REMOVED FROM THE HOLE BY BRUSHING AND <br />AND USING COMPRESSED AIR PRIOR TO APPLYING THE EPOXY. <br />ALLOW THE EPOXY TO CURE TO MANUFACTURER'S SPEQFICATIONS, <br />THEN FILL THE CELL IN THE NORMAL WAY DURING BOND BEAM <br />POUR. <br />4. HURRICANE STRAPS MAY BE SUBSTITUTED WITH A STRAP OF <br />GREATER HOLDOWN VALUE OR GREATER UPUFT VALUE IN THE <br />FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURERS <br />INSTALLATION INSTRUCTIONS ARE FOLLOWED. <br />5. FOR MORTAR JOINTS LESS THAN 1/4", PROVIDE (1) #5 VERT. <br />IN CONC. FILLED CELL EACH SIDE OF THE JOINT ( BAR DOES <br />NOT HAVE TO BE CONT. TO FOOTING) <br /> <br />Structural Design Criteria: <br /> <br />WIND LOADS BASED ON FBC, SECTION 1606,2. <br />WIND VELOCIlY: 123 M.P.H., USE FACTOR: 1.0 <br /> <br /> General Notes: <br /> ~ ~ <br /> THE FOLLOWING TECHINCAL CODES ;~~ ~ <br /> SHALL APPLY: <br /> . ~i~p <br /> () <br /> 2001 FLORIDA BUILDING CODE, Z C5~~ :) <br /> PLUMBING, MECHANICAL, FUEL GAS, . Nco Q:~ ~ <br /> ENERGY EFFICIENCY, ACCESSIBILIlY, ~ ~~ ~a.~ N~ <br /> Z <br /> AND 2002 NATIONAL ELECTRICAL CODES rr::: aJ~l? ~8~ ~ ~ <br /> w ~ g~~ <br /> ORDINANCE 92-19 - APPENDIX "J" W ~~UJ iO ~~ C':l <br /> Z Cl)N <br /> ~~~_aJ ~j; ~ z <br /> TO FBC PLUMBING 2001 CODE. <-' CD .-,..,. ~ ~ ~o 0:: <br /> Z aJ.....aJ ?;:go laB l-' c:! <br />1. TANK lYPE WATER CLOSET VOLUME W . ~~eLJ ~~~ I~ 01 ;a <br />o .. <br /> 1.6 GALLONS a: .. <br /> ~ " <br />2. WALL MOUNT WATER CLOSET VOLUME ~~ m~B !!l ~ <br /> 3.5 GALLONS <-' a. ~ I::: s!!l <br />3. WATER - FLOW RATE. W :i~ ~~ ~~ <br /> ~ <br /> Z <br /> PUBLIC FAOUTIES a,s G.P.M. . . . <br /> PRIVATE FACIUTIES 2.2 G.P.M. <br /> SHOWER HEADS 2.5 G.P.M. <br />4. ALL PLUMBING WATER LINES <br /> TO BE PVPC <br /> <br /> <br /> <br />FLORIDA BUILDING CODE, 2001 EDITION <br />BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02) <br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-89) <br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02) <br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION <br />APA PLYWOOD DESIGN SPECIFICATION <br /> <br />ROOF <br />TOP CHORD <br />BOTTOM CHORD (W /0 STORAGE) <br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED <br />BALCONIES <br />STAIRS <br /> <br />ROOF <br />FLOOR <br /> <br />20 PSF <br />10 PSF <br />40 PSF <br />40 PSF <br />40 PSF <br /> <br />17 PSF (SHINGLE) <br />15 PSF <br /> <br />ALL CONCRETE UNLESS OTHERWISE INDICATED <br />PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY <br />(DO NOT USE FOR CONCRETE COLUMNS OR TIE BEAMS) <br /> <br />2500 PSI <br />3000 PSI <br /> <br /> <br />s <br />o <br />0\ I ~ <br />o ~ l:Q ! .~ <br />:Tj~ ~ i ~ <br />.E ro .doo.c- <br />rJ)o r:r::~~~C'"l <br />I-< ~ 1-<' 11 0\ boO\ <br />2:l Q) 2:l t:-\ c-!.. . rh ~ <br />~~~ ~~~~~8 <br />Q) ~.~ Q) ~ ~ ~ <br />OC'nf)O ~~:fl: <br /> <br />WELDED WIRE FABRIC SHALL CONFORM TO <br />ALL REINFORCING BARS <br />ALL STIRRUPS AND TIES <br /> <br />ASTM A185 <br />ASTM A615-40 40,000 PSI <br />ASTM A615-40 40,000 PSI <br /> <br />VTR LOCATIONS ARE APPROXIMATE <br />AND MAY CHANGE DUE TO JOBSITE <br />CONDITIONS <br /> <br />THE FOLLOWING SHALL COMPLY <br />WITH THE 2001 FBe. <br /> <br />o PORCHES AND BALCONIES <br />SECTION 1014 <br />o HANDRAILS. SECTION 1007.5 <br />o GUARDRAILS - SECTION 1015, 1019.9 <br />o STAIRS - SECTION 1007 <br />o CHIMNEY & FIREPLACE <br />SECTION 2804-2806 (MFGR) <br />SECTION 2113-2114 (MAS) <br />!Xl EGRESS WINDOWS <br />SECTION 1005.4 <br /> <br />ASTM C90 OR C129, STANDARD WEIGHT UNITS, fm=1500 PSI <br />MORTAR lYPE "SO 1900 PSI <br />CONCRETE GROUT 3000 PSI <br />CONTINUOUS MASONRY INSPECTION IS REQUIRED DURING CONSTRUCTION <br /> <br />ALL STRUCTURAL AND MISCELLANEOUS STEEL A36 36,000 PSI, U.N.O <br />SHOP AND FIELD WELDS: E70XX ELECTRODES <br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307 <br /> <br />BEAMS, RAFTERS, JOIST, PLATES, ETe. U.N.O. <br />NO.2 SOUTHERN YELLOW PINE (19% M,c.) <br />ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR, or OS8 <br />FLOOR SHEATHING: 3/4" PLYWOOD (5 PLIES) OR 3/4" T&G .A.DVANTECH <br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB <br />VERSA LAM BEAM Fb = 2900 PSI (2.0E) <br /> <br />4. ALL OPENINGS SHALL COMPLY WITH <br />2001 FBC WIND LOADS AS STATED <br />BELOW. ATTACHMENTS OF WINDOWS, <br />DOORS, SLIDING GLASS DOORS <br />AND O,H. GARAGE DOORS ARE TO DELEGATED <br />THE MANUFACTURER OF THESE ITEMS. THE <br />MANUFACTURER OF THESE ITEMS <br />SHALL SUBMIT ATTACHMENTS FOR <br />SITE INSTALLATION. <br /> <br />SEE ATTACHED SPECIFICATION SHEETS FOR <br />MANUFACTURERS DESIGN CRITERIA AND <br />INSTALLATION METHODS FOR WINDOWS, <br />DOORS, SLIDING GLASS DOORS, OVERHEAD <br />GARAGE DOORS, AND ROOFING. <br /> <br />0, <br />01 <br />~! <br />OJI <br />~O <br />:::S.V <br />5~!~~ <br />........ -a I ........ <br />Vl>cntn <br />>ffi~ch <br />........Q)M\.O <br />Ol-MI"'-.. <br />... <( 0 - I <br />a..!:LLM <br />~llroM <br /><- Ul 0. CO <br />OJ E I <br />3: roM <br />oJ- <br />Z <br />o <br />o <br />~ <br /> <br />DESIGN LOADS: <br />TOP CHORD LIVE AND DEAD LOAD: <br />BOTTOM CHORD LIVE AND DEAD LOAD: <br />TOTAL: <br /> <br />27 PSF <br />20 PSF <br />47 PSF <br /> <br />V1 V1 ~ Z <br />-z 0 <br />~-5::E sa 8a:~ <br />!!;l@g<(tn~~V1~ o~5 <br />~ ::Effia:~ffia:a:z~tJ <br />:::lO'><::Ezu-::EZO<(:::la. <br />O'b1~Q~OQ~Owo~ <br />~~~::j~9~~~~~H <br /><(~ Ciiw~t2wwu-f-;::C <br />~~~~5~~~~~~ <br />o ...... tt p <br />! <br />I <br /> <br />www <br />o:::l:JU <br />~~~ <br />:::>00 <br />0'02 <br />(J)u. <br /> <br />NET UPUFT DESIGN PRESSURE: 20 PSF WITHIN <br />4 FEET OF RIDGES, HIPS, EAVES AND BUILDING <br />PERIMETER AND 15 PSF MIN FOR ALL OTHER AREAS. <br /> <br />SEE DRAWINGS FOR SPECIAL CONCENTRATED LOADS. DESIGN <br />FOR NEW WIND UPLIFT AS PER SPECIFIED CODES, DEDUCTING <br />A MAXIMUM OF 10 P,S,F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL <br />DEAD LOAD. <br /> <br /> <br />DESIGN LOADS: <br />DEAD LOAD: <br />LIVE LOAD: <br />TOTAL: <br /> <br />15 PSF <br />40 PSF <br />55 PSF <br /> <br />5. ALL DOORS INTERIOR & EXTERIOR ARE <br />6'-8" UNLESS OTHERWISE NOTED <br />ALL SHOWER ENCLOSURES TO BE <br />TEMPERED GLASS <br />6. ALL WINDOWS WITHIN 24" OF DOORS <br />(INTERIOR & EXTERIOR) AND WITHIN <br />18" OF FLR TO BE TEMPERED GLASS. <br />(SECTION 2405.2) <br /> <br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF <br />SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS <br />IF SOIL CONDmONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACllY <br />THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO <br />FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN. <br /> <br />Building Data: <br /> <br />Index Of Drawings <br />SHT NO: ITLE <br />A COVER SHEET <br />A1 FLOOR PLAN <br />A2 FOUNDATION PLAN <br />A3 ELECTRICAL PLAN <br />A4.1 ELEVATION I <br />A4.2 ELEVATION II <br />A4.3 ELEVATION III <br />AS.1 ROOF FRAMING ELEV I <br />AS.2 ROOF FRAMING ELEV II <br />AS.3 ROOF FRAMING ELEV III <br />A6 INTERIOR ELEVATIONS 0) <br /> V'l <br />S-l FOUNDATION DETAILS CO c <br /> 0 <br />S-2 LINTEL DETAILS 'in <br />0 .:; <br />S-2A LINTEL PLANS ~ <br />S-3 ROOF FRAMING (I, II, III) 0 ~ <br /> ~ <br />S-4 BRACING DETAILS I (J) <br /> WALL SECTIONS N - <br />S-6 - <br /> 0- <br />S-7 STRUCTU RAL NOTES & LO I <br /> HANGER INFORMATION I ~ <br />S-8 WINDOW & DOOR DETAILS I'- <br />S-9 WINDOW & DOOR DETAILS Q) <br /> 0- <br />S-10 WINDOW & DOOR DETAILS ~ > <br /> ....., <br />S-l1 WINDOW & DOOR DETAILS ~ (J) <br />S-12 PRODUCT APPROVAL INFO LO Q) <br /> L.. <br /> ~ 0 <br /> <br />L.. <br />Q) <br />> <br />o <br />-a <br />c <br /><( <br /> <br />WIND SPEED 123 MPH <br />WIND IMPORTANCE FACTOR -- (Iw) = 1.0 <br />WIND EXPOSURE -- "B" (FBC 1606.1.8) <br />INTERNAL PRESSURE COEFFICIENT = +/- 0.55 (PART. ENCLOSED) <br /> <br />DESIGN WIND PRESSURE: <br /> <br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE) <br /># END ZONE IS ONLY WITHIN 5'-0" <br />OF ALL EXTERIOR BUILDING CORNERS <br /> <br />THEIR OPTIONS ARE AS FOLLOWS: <br /> <br />WINDOWS AND DOORS <br />SEE FLOOR PLAN FOR ACTUAL PRESSURES <br /> <br />A. IMPACT RESISTANT GLAZING <br />B. APPROVED SHUTTERS <br />C. SUPPLY WOOD STRUCTURAL PANELS <br />PER FBC 1606,1.4 <br /> <br /> <br />ANDOVER 2005 <br /> <br />Master Revisions: <br /> <br />ALL WORK SHALL COMPLY WlTH ALL .(' <br />PREVAIUNG CODES, FLORIDA BUILD~ J <br />CODE NATIONAL ELECTRIC CODE AND <br />(lTY OF ZEPHYRHllLS ORDINA."iCES <br /> <br />DATE <br /> <br />DESCRIPTION <br /> <br />.-< <br />r< <br />! <br />~ <br />~ <br />~ <br />~ <br />~ <br />...... <br />"" <br />'" <br />~ <br />j <br />~ <br />i <br />~ <br />j <br />~ <br />! <br />~ <br />~ <br />~ <br />j <br />i <br />1 <br />.a <br />,/ <br />,/ <br /> <br />REVIEWED <br />t-1AY 0 9 2.005 <br /> <br />~ i5wr <br /> <br />CENTRAL FLORIDA DIVISION, <br />TAMPA, FLORIDA 33609 <br /> <br />Lf) <br />o <br />o <br />N <br /> <br />ro <br />3: <br />E <br />2 <br />(f) <br /> <br />>-f- <br />~z <br />I ZW <br />,....d2z <br />l:j@8~ <br />~~z~ <br />o~~~ <br />Za.:>Cl.. <br />. w:>~ <br />l-- ~ c::( <br />rr-wWI- <br />;"&"OOF=W <br />~555 <br />!XZOI <br />>- ?:( :c (J) <br />~~~~ <br />o~~o <br />U:)wct <br />a.zLL <br />(J)Z <br />.......<( <br />:c~ <br />f- <br /> <br />ENGINEERED PLANS <br />ON FILE <br /> <br />Notice To Builder <br /> <br />>- <br />0::: <br />o <br />I- <br />Z <br />W <br />> <br />Z <br /> <br />en <br />co LAST PLOT DATE <br />15 Mar. 23, 05 I <br />~ COVER SH~ET <br /> <br />w <br />~ <br />O~ <br />02 <br />~ <br />~a.. <br />() SHEET NO. <br />o <br /> <br />- <br /> <br />CO <br /> <br />600 N. WESTSHORE BLVD. SUITE 600 <br />(813) 769-5277 <br /> <br />IT IS THE INTENT OF THIS DESIGNER THAT <br />THESE PLANS ARE ACCURATE AND ARE <br />CLEAR ENOUGH FOR THE UCENSED PROFESS- <br />ONAL TO CONSTRUCT THIS PROJECT. <br />IN THE EVENT THAT SOMETHING IS UNCLEAR <br />OR NEEDS CLARlFICATION..STOP..AND CALL <br />THE DESIGNER USTED IN THIS TITLE PAGE. IT <br />IS THE RESPONSIBIUlY OF THE LICENSED <br />PROFESSIONAL THAT IS CONSTRUCTING THIS <br />PROJECT TO FULLY REVIEW THESE DOCUMENTS <br />BEFORE CONSTRUCTION BEGINS AND ANY AND <br />ALL CORRECTIONS, IF NEEDED, TO BE MADE <br />BEFORE ANY WORK IS DONE. <br /> <br />a.: <br />cr::: <br />o <br />u <br />W <br />~ <br />o <br />:c <br />(J) <br />::J <br />LO <br />o <br />~ <br />@ <br /> <br />A <br /> <br />- <br />