<br />CAULK BETIJEEN
<br />\.IoOD BUCK S.
<br />MAS'Y, OPENING
<br />BY OTHERS
<br />
<br />CAULK BET\.IEEN
<br />DOOR FLANGE -,
<br />S. \.IoOD BUCK
<br />PERIMETER
<br />CAULK BY -\ v
<br />OTHERS \
<br />
<br />I
<br />~\-4
<br />STUCCO ~
<br />BY OTHERS
<br />
<br />INSTALLATION ANCHOR ~
<br />#8 SCRE\J VOOD <T'(P. ---1
<br />VHERE TAPPERS ARE
<br />NOT REQ'D, - NOTE 22)
<br />
<br />L SLIDING GLASS
<br />DOOR FRAME
<br />HEAD
<br />
<br />SECTION A-A
<br />
<br />""'-TEMPERED
<br />GLASS <TYP.)
<br />
<br />&
<br />
<br />CAULKING &
<br />REQUIRED
<br />(SEE NOTE 2),
<br />
<br />CAULKING AT FASTENER
<br />HOLES REQUIRED
<br />(SE.E NOTE 2),
<br />
<br />\
<br />
<br />SLIDING GLASS
<br />DOOR FRAME-
<br />SILL
<br />
<br />'-'
<br />
<br />'-'
<br /> ;;:z;
<br /> I
<br />~ lIf~ Ije>,
<br /> 112' /1
<br />A /> t A
<br />
<br />&
<br />
<br />114' MAX]
<br />SHIM SPACE
<br />
<br />. e> .
<br />I 4
<br />
<br />I Y
<br />
<br />'II
<br />
<br />A
<br />
<br />4
<br />
<br />A
<br />
<br />A
<br />
<br />A
<br />
<br />A
<br />
<br />e>
<br />EMBEDHENT -
<br />1-114' MIN,
<br />
<br />L INST ALLA TlON ANCHOR
<br />3/16' DIA. TAPPER
<br /><NOTE 17>
<br />CONCRETE OR
<br />L MASONRY OPENING
<br />BY OTHERS
<br />
<br />t>
<br />
<br />INSTALLATION ANCHOR
<br />!l8 IJOOD SeREI..' \o!/PlASTlC
<br />ANCHOR (TYP. VHE.RE
<br />;).. TAPPtRS ARE NOT REa'D.
<br />m SEE NOTE 22)
<br />LIBERALLY APPLY
<br />CAULKING UNDER SILL
<br />DR SET SILL IN BED
<br />Of' CONCRETE (SEE NOTE 2),
<br />SHIM AS REQUIRED (SEE NOTE 1).
<br />
<br />\
<br />
<br />SHEA THING
<br />BY OTHERS
<br />
<br />SHIM AS RE'Q'D
<br />(SEE NOTES)
<br />r CAULK BE TVEEN
<br />DOOR FLANGE
<br />I B. SHEATHING
<br />
<br />k
<br />I
<br />I
<br />
<br />\
<br />/\
<br />
<br />STUCCO
<br />OR SIDING
<br />BY OTHERS
<br />
<br />=-dO I ""'"
<br />
<br />I~
<br />
<br />PERIME T E R -----1
<br />CAULK BY
<br />OTHERS
<br />
<br />L SLIDING GLAS~
<br />DOOR FRAME
<br />HEAD
<br />
<br />
<br />~TEMPERED
<br />"" GLASS
<br /><TYP,)
<br />
<br />DOOR
<br />HEIGHT
<br />
<br />&
<br />CAULKING AT FASTENER
<br />HOlES REQUIRED
<br />(SEE NOTE 2),
<br />
<br />CAULKING &
<br />REQUIRED
<br /><SEE NOTE 2),
<br />
<br />....
<br />,:.l
<br />I
<br />
<br />..IC
<br />
<br />~
<br />~
<br />,:.l
<br />....
<br />,:.l
<br />....
<br />
<br />SLIDING GLASS
<br />DOOR FRM~E l
<br />SILL
<br />& \
<br />'1
<br />
<br />~
<br />
<br />;,~I
<br />
<br />"-"
<br />
<br />;;=;;;
<br />
<br />I
<br />
<br />lie> t
<br />
<br />I
<br />
<br />:1
<br />
<br />1/4' MAX]
<br />SHIM SPACE
<br />
<br />1/2'/1
<br />t EMBEDMENT
<br />A 1-114' MIN.
<br />
<br />~ t 4
<br />
<br />I
<br />A I
<br />~
<br />
<br />~
<br />~
<br />;;,
<br />r
<br />-j
<br />t
<br />i
<br />i
<br />
<br />,.-
<br />~
<br />e;
<br />&l
<br />,.-
<br />~
<br />!
<br />i
<br />J
<br />~
<br />,.-
<br />:':i
<br />
<br />4
<br />
<br />/1
<br />
<br />A
<br />
<br />A
<br />
<br />t>
<br />
<br />A
<br />
<br />t>
<br />
<br />INSTALLATION ANCHOR
<br />#S 1..'000 SeRE\of \of/PLASTIC
<br />ANCHOR (TYP, VHERE:
<br />TAPPERS ARE NOT REQ'O.
<br />SEE NOT E 20)
<br />
<br />_ INSTALLATION ANCHOR
<br />3/16' DIA, TAPPER
<br />(NOTE 15)
<br />CONCRETE DR
<br />- MASONRY OPENING
<br />BY OTHERS
<br />
<br />&
<br />LIBERALLY APPLY CAULKING
<br />UNDER SILL OR SE T SILL IN
<br />BED Of' CONCRETE (SEE NOTE 2),
<br />SHIfoI AS I<:EGlUIRED (SEE NOTE D.
<br />
<br />SECTION A-A
<br />
<br />DOOR
<br />HEIGHT
<br />
<br />t
<br />
<br />MASONRY INSTALLATION
<br />
<br />--.-114' MAX, SHIM SPACE
<br />1 114' MIN,
<br />1--- - -EMBEDMENT
<br />~ ONE BY ~OOD
<br />V- BUCK BY OTHERS
<br />~ (NOTE 11 S. 1~
<br />
<br />\ CAULK BET~EEN
<br />q ~OOD BUCK ~
<br />\ I' .......-:-- MAS'Y, OPENING
<br />~ BY OTHERS
<br />.v !-----f----- SHIM AS REQ'D,
<br />__ (SEE NOTES)
<br />
<br />l'\~ I:STALLATION ANCHOR
<br />3/16' DIA, TAPPER (NOTE
<br />I ~ ~CAULK BETVEEN
<br />~ DOOR FLANGE
<br />~. B. \./000 BUCK
<br />PERIMETER ____."".. '-
<br />CAULK BY CONCRETE DR
<br />OTHERS ...... MASONRY OPENING
<br />BY OTHERS
<br />---- $,G,D. \"IDTH -.....
<br />STUCCO
<br />BY OTHERS
<br />
<br />.6.. CONCRETE OR
<br />ill --- ~ MASONRY OPENING
<br />2X4, 2X6, OR 2X8 \.IooD --., .d BY OTHERS
<br />BY OTHERS (NOTE 6)
<br />, d
<br />
<br />u
<br />
<br />INSTALLATION ANCHOR _~
<br />#8 \.IODD SCRE\.I <TYP,)
<br />(NOTE 23)
<br />(ANCHORS SHO'*,N IN SAME
<br />PLANE FOR CLARITY ONLY,
<br />HOOI< STRIP ANCHOR HOLES
<br />SPACED 2' APART ON 1'118' MIN.
<br />OPPDSITE FLANGES) '\ t EM13EDME~T .
<br /><TYP.) c1
<br />SLIDING GLASS DOOR ~ d ~
<br />HOOK STRIP 4
<br />ri-- 1-- \ ~ 1:..~c1 ,", ...;> ,
<br />17) l/..__ "'" -=.. 3/4'
<br />
<br />TEMPERED GLAS7 ,.... r ~/-'- t
<br />(TYP) '"
<br />~D STUCCO
<br />\ BY OTHERS
<br />~ // L SLIDING GLASS DOOR
<br />INTERLOCK
<br />HOOK STRIP DETAIL
<br />IMPORTANT INFORMATION &. GENERAL NOTES
<br />
<br />MAX.
<br />
<br />.d'
<br />
<br />CAULK BET\.IEEN
<br />HOOK STRIP 8c
<br />\.IOOD BUCK
<br />
<br />~
<br />
<br />SECTION B- B
<br />
<br />These notes are provided to ensure proper installation of Florida Extrudef1 Milestone prodlJcts and must be followed fully.
<br />
<br />GENERAL INSTALLATION INSTRUCTIONS
<br />
<br />A........
<br />
<br />1) SHIM /4S REQ'O. AT EACH INSTAlLATION ANO-IOR WITH LOAD BEARING SHIM. MAX. ALLOWABLE SHIM STACK TO BE 1/4".
<br />lOAD BEARING SHIM AT SrLL MUST BE PRESSURE TREATED WOOD OR PlASTIC AND MUST BE COMPlETELY ENCAPSUlATED IN
<br />CAUlKING OR SET INTO WET CONCRETE.
<br />2) USE SIUCONIZEO ACRYUC CAULK BEHIND DOOR FlANGE AT HEAD & JAMBS. LIBERAllY AWl Y SIUCONIZED ACRYLIC
<br />CAULKING UNDER SILL OR SET SILL IN BED OF WET CONCRETE, CAULK BETWEEN BACK CORNER OF SrLL RISER AND
<br />CONCRETE. CAULK ALL FASTENER HOLES PRIOR TO INSTALUNG FASTENER AND AROUND HEAD AFTER INSTALIAT10N,
<br />3) use SILICOtiIZED ACRYLIC CAULK FOR PERIMETER SEAL AROUND EXTERIOR OF DOOR AND BETWEEN HOOK STRlP & 8UCK
<br />FOR POCl<ET I)()()RS.
<br />4) JAMB AND SILL CORNERS ARE TO BE SEALED WITH A SMALL JOINT SEAM SEALER.
<br />5) DOOR FRAME MATERIAL: ALUMINUM AllOY 6063.
<br />6) TWO BY WOOD BUCK AND/OR FRAMING AT THE HOCKSTRIP TO BE SECUREt Y FASTENEO TO TRANSfER THE LOAD TO Tl-IE
<br />& MASONRY, CONCRETE O~ OTHER STRUCTURAL SUaSTRATe PE.R FOC, SKHON 1701.4.4.2 AND THE ENGINEER OF RECORD'S
<br />DETAILS.
<br />7) FLORIDA EXTRUDERS 1000 SERlES SUDING GlASS DOOR )S SHOWN. THlS PlUNT ALSO APPl1ES ro Tl-IE FtOIUDA
<br />EXTRUDERS SOO AND 2000 SERlES Sl1DLNG GlASS DOORS.
<br />B) WHERE "X. REPRESENTS MOVING PANEl AND "0" REPR.ESENTS FIXED PANEL, APPROVED CONFIGURATIONS ARE /tS USTED
<br />ON Tl-IE ANCHOR INSTALIAT10N OiART.
<br />
<br />#
<br />
<br />#
<br />
<br />&
<br />r,
<br />B B
<br />
<br />&
<br />
<br />A.......
<br />EXTERlDR ELEVATION
<br />2 PANEL DOOR SHOWN
<br />(SEE NOTES 8, 9 8. 10)
<br />
<br />N
<br />tJ~
<br />a:~
<br />do
<br />~z
<br />
<br />!~
<br />~~
<br />~~
<br />
<br />~,,\\\\\\,\,~
<br />~ 4t Nrl,t);~~
<br />.... ...~~~
<br />I.~j '~'~.". \\ REV D.ESCRIPTION
<br />'t,. ~ \ B REViSED NOTES I, 2, J. 6,
<br />! \ ~... 11, 12. 13. 16.22. 23 &
<br />~[~ 31 mo ADDEO AND/OR
<br />.. ~.u7 }'~ !"'J REVISED RELATED
<br />.. . r.f'I".. ~ RUtRENCES AND/OR
<br />ll.,~~. .....~. ,.~ IlLUS TAA nONS. RENU~BERED
<br />') ", 1':" .i" '/ NOTl:S 6 TO 10 AND
<br />~., ........,.. REVISED REfERENCES TO
<br />.. . ";oi'D" T\1ESE NOTES.. REVISED
<br />.~ TAPPERS ro~ 9<lXX
<br />3-PANEL DOORS.
<br />
<br />DATE INI FLORIDA EXTRUDERSl~~~~N1~~OE~L,~~
<br />12/18/03 RJA CERTIFICATe: Of AUlttORIZATlON NO, 9235 SANFORD. FLORIDA
<br />TiTLE: SLIDING GLASS DOOR 500, 1000 8. 2000
<br />MASONRY INSTALLATION VITH NON-STRUCTURAL
<br />BUCK AND TAPPERS
<br />DRAWN BY:BB APPROVED BY: RJA
<br />DATE: 12/18/03 I SCALE: NTS DWG #: FLEX0021 SHEET 1 OF 2
<br />
<br />(SEE Sl~EET 2 fOR CONTINUATION OF NOTES]
<br />
<br />FRAME INSTALLATION
<br />
<br />----DOOR \.IIDTH -- F1I4' MAX. SHIM SPACE
<br />1-118 MIN.
<br />......-- - -EMBEDMENT
<br />SLIDING GLASS
<br />DOOR F'RAME
<br />JAMB T\.IO BY \.1000 INSTALLATION ANCHOR
<br />\ ! r BY OTHERS 148 IJODD SCRE'.! (TYP,) --...
<br />(NOTE 6) (NOTE 21>
<br /><ANCHORS SHDVN IN SAME
<br />({; ~ PLANE: roR CLARITY ONLY.
<br />j HOOK STRIP ANCHOR HOLES
<br />SPACED 2' APART ON
<br />-- _fJ./.r- SHIM AS REQ'D, OPPOSITE FLANGES'> 1 1/8' MIN.
<br />V (SEE NOTES) - \ E ~BEm"ENT
<br />
<br />\ ~6b~1NJ3T~IttSS DOOR~I I '\ / /\ mp) I
<br />
<br />/ \ INSTALLATION ANCHOR rt-- ~\ /,."
<br />~ ita VOOD SCRE\.I V \ II ,~ ~~ 3/4' MAX,
<br />(NOTE 21> ",... ",,"
<br />
<br />-- CAULK BETVEEN TEMPERED '7 L t
<br />DOOR FLANGE GLASS (TYP,) ~
<br />,I!. SHEA THING SHEATHING
<br />~ ~III ~ BY OTHERS
<br />"'" -z I L SLIDING GLASS DOOR
<br />INTERLOCK
<br />HOOK STRIP DET AIL
<br />
<br />TVO BY \.IoOD BY
<br />OTHERS <NOTE 6) ~
<br />
<br />,
<br />
<br />l,fAULK BETVEEN
<br />'I HOOK STRIP ~
<br />\.IOOD BUCK
<br />
<br />'"
<br />
<br />.c:::.I..
<br />
<br />~{
<br />
<br />u
<br />
<br />f III
<br />
<br />
<br />IEM:
<br />
<br />(TYP.)
<br />
<br />.J
<br />
<br />GLASS
<br />
<br />?(
<br />
<br />PERIMETER
<br />CAULK BY
<br />OTHERS
<br />
<br />SHEATHING
<br />BY OTHERS
<br />
<br />STUCCO
<br />OR SIDING
<br />BY OTHERS IMPORTANT INFORMATION 8t GENERAL NOTES
<br />These liOtes are provided to ensure proper Installation of Aorfda Extruders Milestone products and must be
<br />followed fully.
<br />
<br />SECTION B- B
<br />
<br />AI
<br />I
<br />
<br />GENERALINSTAlLATIONINSTR~ONS
<br />
<br />#
<br />
<br />#
<br />
<br />;).. 1) SIiIM AS REQ'D. AT fAOi INSTALLATION ANCHOR Wmi lOAD 8fARlNG SHIM. MAX. ALLOWABLE SHIM STACK TO
<br />ill BE 1/4". LOAD 8EARING SHIM AT SILL MUST BE PRESSURE TREATED WOOD OR PlASTIC AND MUST BE COMPLETELY
<br />.- _ ENCAPSULATEO IN CAULKING OR SeT INTO WET CONCRETE.
<br />, t 2) USE SIUCONIlED ACRYliC CAULK BEHIND DOOR FlANGE AT HEAD &.JAMBS. UBERALLY APPLY SIUCONIlED
<br />B B ACRYLIC CAULKING UNDE.R SILL OR SET SILL IN BEO OF WET CONCRETE. CAULK BETWEEN BACK CORNER OF SILL
<br />b.. RISER AND CONCRETE. CAULK ALL FASTENER HOlES PRIOR TO INSTALUNG FASTENER AND AROUND HEAD AFTER
<br />m INSTALLATION.
<br />3) USE SlUCONIZED ACRYLIC CAULK FOR PERIMETER SEAL AROUND EXTERIOR OF DOOR AND BETWEEN HOOK STRIP
<br />&. BUCK FOR POCKET DOORS,
<br />4) JAMB AND SIll CORNERS ARE TO BE SEAlED wm~ A SMAll JOINT SEAM SEALER.
<br />5) DOOR fRAME MATERIAL: ALUMINUM AllOY 5063.
<br />b.. 6) TWO BY WOOO BUCK ANDIOR fRAMtNG AT THE HEAD, .lAMa AND HOOKSTRIP TO BE SECURELY FASTENED TO
<br />m TRANSfER THE lOAD TO THE WOOD OR APPROVED FRAMING ~1EMBERS PER FBC. SECTION 1707.4.4.3 AND THE
<br />ENGINEER OF RECORD'S DETAILS.
<br />
<br />I
<br />A-J
<br />-}} EXTERIOR ELEVATION
<br />~ 2 PANEL DOOR SHOWN
<br />(SEE NOTES 8, 9 8. 10)
<br />
<br />tJ~
<br />a:~
<br />~~
<br />t~
<br />~~
<br />i~
<br />
<br />'~''''\\~\''l,~
<br />~ ~ ~~_'i.
<br />
<br />r.1fY/~~~'\ HEV DESCRIPTION DATE IN!
<br />
<br />it, · \ ~ B ~~ &NOj}S...J6 Mn8. 11, 12118/03 RJA
<br />"'--t! s, ..... ! 'ta - IINO/OR Rl'V1SEO RElA"EO
<br />, ~ ~ '~"'I Rt:f"ERDICES mo/OR
<br />-.. t .,~ ""!'.:"'I~' 'J ILLVSTRATlOss. ..00(1) NOTe:
<br />. _..' .; 2OMO RElATEO
<br />'. .0' ILLliSTRATlONS. RO(UM8EREl)
<br />\~. '0. . ~~. Iii') OOl1:$ 9 TO 10 & 21 TO 29
<br />, St · u ., \. !\NO REw.;[O REFERENCES TO
<br />'. THtSE NOTES. !l(\llsm
<br />""'" ~ TN'I'tIlS F'OR 90XX 3-f'!\Nn
<br />~. OOORS.
<br />
<br />SCALE:
<br />
<br />APPROVED BY: RJA
<br />NTS !nWG #: fLEX0027 SHT 1 OF 2
<br />
<br />[SEE SHEET 2 r-OR CONnNUATION OF NOTES]
<br />
<br />FLORIDA EXTRUDERSI~Ts~~N~i~O:#'J~~
<br />CtRTIF\CATe: OF AUThORIZATION NO. 92J5 SANFORD FLORIDA
<br />TITLE: SLIDING GLASS DOOR 500) 1000 ~ 2000
<br />FRAME INST ALL A TION W'ITH #8 SCREW'S
<br />
<br />DRAWN BY: BB
<br />DATE: 12118/03
<br />
<br />.~--
<br />
<br />o ~1O
<br />~ coco~~
<br />l.L. Ol'" co I
<br />W IO~O~~
<br />w ~I'1OlOlN
<br />z ~ ~~_co
<br />o CD ex; ~ IIi
<br />~ d ~~etJ
<br />a.:3Q"
<br />....J I: )(
<br />~ ~~
<br />o c..
<br />W
<br />I-
<br />Z
<br />
<br />~
<br />I!l t.J I
<br />o j!:
<br />~~~ ~
<br />~i~ VI I
<br />:>.~~ ~
<br />Q!~CD :2
<br />~Q.~ N~
<br />~~~ ~~ ~
<br />z ~ .
<br />t<-t.J 00 u;.~
<br />~~j!: ~~ ~
<br />~~15 ~f3 ~~
<br />~c~ u~ ~~
<br />O~8 I~ io
<br />ffi~1ii oc I~
<br />f50~ VI~ j!:
<br />:~:S ~~ ~
<br />
<br />I ~
<br />1
<br />t4
<br />Q.
<br />Ii
<br />
<br />i
<br />
<br />..~~
<br />~.~\
<br />~~
<br />o
<br />z
<br />
<br />(.)
<br />
<br />~
<br />
<br />.
<br />
<br />. .
<br />
<br />INSTALLATION ANCHOR INSTALLATION ANCHOR -_
<br />3/16' DIA. TAPPER lt8 \.IOOD seRE'" (TYP. \.IHERE
<br />(NOTE 17) TAPPERS ARE NOT
<br />CONCRETE OR ONE BY I,JOOD REQ'D. - NOTE 22)
<br />MASONRY OPENIN~G r-- BUCK BY OTHERS
<br />BY OTHERSl (NOTE 11 8c 12)
<br />SHIM AS & /h ~
<br />(SEE 1 SLIDING GLASS
<br />::~:~S) -' DOOR FRAME \
<br />... 1 1/4' MIN, JAMB
<br />EMBEDMENT - 114' MAX.
<br />~ . SHIM SPACE ~~
<br />-
<br />~- F-- .....".-- ..- -...-- ."....I{
<br />__ r - t-- f III
<br />
<br />
<br />~\ J Ii '] If I IEMP:D GLAS;~
<br />
<br />(TYP')
<br />
<br />~I\
<br />~,
<br />~~
<br />V~
<br />~ I
<br />t..,.., .
<br />
<br />- .
<br />
<br />
<br />\J> ~~
<br />- <(
<br />V ; ~ J:
<br />u."J i
<br />,.., ~
<br />
<br />~ .....
<br />
<br />wWw
<br />~l!)u
<br />~~~
<br />::>00
<br />5Sf(z
<br />
<br />Q)
<br />CO
<br />o
<br />o
<br />I
<br />C\J
<br />lC)
<br />I
<br />"-
<br />~
<br />~
<br />lC)
<br />~
<br />
<br />>-
<br />a::
<br />o
<br />J-
<br />Z
<br />W
<br />>
<br />Z
<br />
<br />-
<br />
<br />~
<br />u
<br />U
<br />~ ~ .S
<br />.9 LO ~ 1J
<br />] -g c<') 0 00 .c-
<br />[f)O ti~~~c<')
<br />I-< C!:: k' 1 0'1 enO'l
<br />Q) Q) Q) ~ ~ ..... ~
<br />~~ ~~~~o
<br />~~~ ~~~ ~.~
<br />~ ~'S Q) ~ ~ ~
<br />UN[f)Oo..~ #:
<br />
<br />V'l V'l ~ <:
<br />-z -z 0::0
<br />0~~~~~~ ~~8
<br />~Q~tDft~ffifto::z~~
<br />:::lo><;~zu.~zo<{:::lR-
<br />~Kl~o~8o~Q~8;;:
<br />~~~~l-'e~l-'~ff~~
<br />~~i~~~~~~~~
<br />
<br />o >-< U. Cl
<br />
<br />II
<br />
<br />
<br />Vl
<br />C
<br />o
<br />'in
<br />'S;
<br />~
<br />
<br />~
<br />~
<br />(/)
<br />
<br />-
<br />-
<br />.-
<br />
<br />I
<br />~
<br />Q)
<br />
<br />.-
<br />>
<br />+J
<br />(f)
<br />Q)
<br />L.
<br />()
<br />
<br />LI")
<br />o
<br />0=
<br />Nro
<br />~$
<br />Q) E
<br />> Q)
<br />Q+-'
<br />-c(f)
<br />c:
<br /><(
<br />
<br />>-
<br />zl-
<br />c::( Z
<br />i W
<br />~~z
<br />W.oo
<br />U~Uti)
<br />t-4 :D~ Z ~
<br />t- Q 0
<br />02 c::(
<br />Z l:t ~ c..
<br />....~w~
<br />G~~~
<br />~ol-o
<br />a:=?5:c
<br />>-~:C(J)
<br />a.. -..... t: :J
<br />O~$:::E
<br />u!~~
<br />F~
<br />
<br />INSTALLATION ANCHOR
<br />#8 \.IOoD SCREW'
<br />(NOTE 21>
<br />I T\.Io BY VOOD
<br />BY OTHERS
<br />(NOTE 6)
<br />
<br />^ - 114' MAX,
<br />/ \ SHlM SPACE
<br />
<br />
<br />~ ~ I ~
<br />
<br />" .. 1-1/8' MIN.-
<br />EMBEDMENT
<br />
<br />w
<br />::E
<br />0;2
<br />oz I
<br />~~ i
<br />() SHEET NO. I a.:
<br />O I rx:
<br />I 0
<br />
<br />~Sl]1
<br />
<br />CO LAST PLOT DATE; ~
<br />(5 Mar. 22, 05 I @)
<br />.-J I
<br />I
<br />I
<br />
|