<br />r
<br />
<br />INSTALLATION OF WINDOW
<br />BUCK STRIPS - lx3 (MIN). GLUE
<br />STRIP W/ADHESIVE SEALANT
<br />& SCREW Wj3j16" x 2 lj211 PHILLI
<br />FLAT HD. "TAPeON" SCRE:W MIN.
<br />4" FROM END & 1611 O.C.
<br />
<br />
<br />EXT. FINISH
<br />DRIP EDGE
<br />INSTALLATION OF S.G.D.
<br />BUCK STRIPS - lx4 (MIN). GLUE
<br />STRIP W/ADHESIVE SEALANT
<br />& SCREW W/3/16" x 2 1/2"
<br />PHILLIPS FLAT HD. "TAPCON"
<br />SCREW MIN. 4" FROM END
<br />& 16" O.C.
<br />TRACK - FILL ALL HOLES
<br />W/l" x #8 ST. STL. SCREWS
<br />W/PLASTIC ANCHORS I .-'"
<br />SEALANT
<br />
<br />MASONRY OPENING
<br />S.G.D. INSTALLATION
<br />
<br />SCALE: N.T.S
<br />
<br />BLOCK LINTEL
<br />
<br />1/2" DRWALL
<br />BUCKSTRIP - lX3 MIN (WINDOW)
<br />1/8" SHIM s~\MIN (SGD)
<br />WINDOW/SGD
<br />
<br />g~~~~~ JAMB
<br />11/2" RECESS
<br />IN SLAB
<br />SLIDING GLASS
<br />DOOR
<br />
<br />
<br /> . TIE BEAM .
<br /> . PRECAST LINTEL -.
<br />(/)
<br />W
<br />0:: FASTEN PT 2X 8 BUCK TO
<br /><(
<br />>
<br /> MASONRY Wj 3116" X 3"
<br /> TAPCONS 6" FROM ENDS
<br /> AND 16" O.C. MAX.
<br /> FASTENING WINDOW TO
<br /> BUCK RESPONSIBILTY OF
<br /> WINDOW MANUFACTURER.
<br /> /
<br /> /
<br />
<br />
<br />2 X 8 BUCK DETAIL
<br />SCALE: N.T.S,
<br />3-15-04 TH
<br />
<br />L
<br />
<br />3
<br />
<br />
<br />2
<br />
<br />TYP. 8" BLOCK WALL
<br />
<br />1
<br />6" BITUMINOUS TAPE INSTALLATION SEQUENCE
<br />
<br />----~
<br />
<br />1 X P.T. WI 3/16" X 2 1/4"
<br />TAPCONS @ 18" OIG MAX.
<br />& 6" FROM CORNERS
<br />
<br />EXT. FINISH ---1
<br />JAMB. FILL I
<br />ALL HOLES W j I
<br />l-1j2"X#8 (MIN.),
<br />SC/{EW
<br />I
<br />
<br />SEALANT
<br />BACK OF ALL
<br />JAMBS
<br />TRACK - FILl:
<br />ALL HOLES W j
<br />1"X#8 (MIN.)
<br />SCREWS WI
<br />PLASTIC ANCH.
<br />
<br />
<br />
<br />WINDOW HEADER
<br />2 - 2"X12" S.Y.P.
<br />UNLESS OTHERWISE
<br />SPECIFIED
<br />1/2" D.W.
<br />------TRIM
<br />
<br />(SEE PLAN)
<br />S,G.D. JAMB
<br />
<br />'-- 3j4" RECESSED
<br />SLAB
<br />SEALANT
<br />
<br />MAS. WALL EXT.DOOR JAMB
<br />
<br />
<br />
<br />SCALE: N.T.S.
<br />
<br />FRM. OPNG. SGD INSTALL
<br />
<br />SCALE: N.T.S.
<br />
<br />
<br />h
<br />
<br />([):
<br />[
<br />zV
<br />
<br />o
<br />
<br />@
<br />
<br />I~
<br />
<br />-------
<br />
<br />@
<br />
<br />
<br />:@
<br />
<br />
<br />a: ) 10 PERCENT OF LEAST HORIZONTAL DIMENSION OR O.4h, WHICHEVER IS SMALLER, BUT NOT
<br />LESS THAN EITHER 4% OF LEAST HORIZONTAL DIMENSION OR 3 FT ( 1 m).
<br />
<br />COMPONENT & CLADDING DESIGN PRESSURE
<br />(120 MPH, 3 SEC GUST. 2.1/12 PITCH, EXPOSURE B, HEIGHT = 0 TO 30 FEET, IMPORTANCE FACTOR = 1 )
<br /> (PSF)
<br />TRIBUTARY AREA ROOF WALL
<br />(FT2)
<br /> (GCpi = +/- .18) (GCpi = +/- .18)
<br /> ZONE 1 ZONE 2 & 3 ZONE 4 ZONE 5
<br />10 14.9 -23,7 14.9 -50.1 25.9 -28.1 25.9 -34.7
<br />20 13.6 -23.0 13.6 -45.4 24.7 -26.9 24.7 -32.4
<br />50 11,9 -22.2 11.9 -39,3 23,2 -25.4 23.2 -29.3
<br />100 10.5 -21.5 10.5 -34.7 22,0 -24.2 22.0 -26.9
<br />125 10.5 -21.5 10.5 -34.7 21,7 -23.6 21.7 -26.2
<br />NOTES: 1 FOR EFFECTIVE AREAS OR WIND SPEEDS BETWEEN THOSE GIVEN
<br /> ABOVE THE LOAD MAY BE INTERPOLATED, OTHERWISE USE THE
<br /> LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA.
<br />2 TABLE VALUES SHALL BE ADJUSTED FOR HEIGHT AND EXPOSURE
<br /> BY MUL TIPL YING BY ADJUSTMENT COEFFICIENTS IN TABLE 1606.2D
<br /> OF THE FLORIDA BUILDING CODE 2001.
<br />3 PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD
<br /> AND AWAY FROM THE BUILDING SURFACES.
<br />
<br />FILLED CELL Wj
<br />#5 VERTICAL
<br />
<br />1/2" X 8" A.B.
<br />W/2" WASHERS
<br />SET IN TYP.
<br />FILLED CELL
<br />MIN. 5 PER
<br />JAMB.
<br />
<br />
<br />(5) 1/2" DIA. x 8"
<br />"J" BOLTS
<br />
<br />CONT. WOOD TRIM
<br />
<br />P.T. #
<br />SYP 2" X 6"
<br />
<br />
<br />OVERHEAD
<br />SECTIONAL
<br />DOOR TRACK
<br />Wj 3/8" X l1j2"
<br />STEEL LAG
<br />BOLT WI
<br />WASHER. MIN,
<br />6 PER TRACK
<br />TO JAMB.
<br />
<br />2"x6" P.T. WOOD JA!'v1B
<br />
<br />DOOR AND CONNECTION PER
<br />GARAGE DOOR MANUFACTURER
<br />TYP. GARAGE DOOR
<br />
<br />TRACK MOUNTING DETAIL
<br />
<br />~
<br /> 0
<br /> ..-i L SECTIONAL
<br /> ,
<br /> ;,
<br /> OVERHEAD
<br /> 0 DOOR 7
<br /> ..-i
<br /> ,
<br /> ;,
<br /> .
<br /> :r
<br /> ..-i
<br /> . GARAGE SLAB
<br /> q
<br /> I
<br /> ;,
<br />@
<br />~ co
<br />
<br />SECT. OVERHEAD GAR. DOOR INSTALL
<br />SCALE: N.T.S. I\OTE: THIS DETAIL HAS A CAPACITY THAT IS EQUAL TO OR
<br />3-15-D4 TH GREATER THAN THAT RECOMMENDED BY MANUFACTURER.
<br />
<br />
<br />-EQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS
<br />(RE: FBC 2405.1 & 2405.2.1)
<br />
<br />2405.1 General. Individual glazed areas including glass mirrors in
<br />hazardous locations such as those indicated in 2405.2 shall
<br />pass the test requirements of CPSC 16-CFR, Part 1201 or
<br />by comparative test shall be proven to produce at least
<br />equivalent performances,
<br />
<br />Exceptions:
<br />1. Polished wire glass installed in fire doors, fire windows and
<br />view panels in fire resistant walls and hazardous locations in
<br />2405.2.1 (3) and 2405,2.1 (4) shall comply with ANSI Z97.1.
<br />2. Approved plastic materials used as glazing in hazardous
<br />locations shall comply with ANSI Z97.1.
<br />
<br />2405.2 Hazardous Locations
<br />2405.2.1 The following shall be considered specific hazardous locations for the purpose
<br />of glazing:
<br />1. Glazing in swinging doors and fixed and sliding panels of sliding (patio)
<br />door assemblies.
<br />2 Glazing in doors and walls of enclosures for hot tubs, whirlpools, saunas, steam
<br />rooms, bathtubs, showers, and other such facilities where such glazing is located
<br />36 inches (914 mm) or less, measured horizontally, from a standing or walking
<br />surface within the enclosure and where the bottom edge of the exposed glazing is
<br />less than 60 inches (1524 mm), measured vertically, above such standing or walking surface.
<br />
<br />3. Glazing in an individual fixed or operable panel adjacent to a door where the
<br />nearest vertical edge is within a 24-inch (610 mm) radius of the door in a
<br />closed position and whose bottom edge is less than 60 inches (1524 mm)
<br />above the floor or walking surface.
<br />
<br />EXCEPTION: Glazing in walls perpendicular to the plane of the door in a closed position in
<br />Group R3 or within dwelling units in Group R2 shall be subject to 2405,2.1 (4).
<br />
<br />4. Glazing in an individual fixed or operable panel, other than those locations
<br />descried in items 2 and 3 above, that meets all of the following conditions:
<br />1. Exposed area of an individual pane greater than 9 sq. ft (0.84 m sq.).
<br />2. Bottom edge less than 18 inches (457 mm) above the floor.
<br />3. Top edge greater than 36 inches (914 mm) above the floor,
<br />4. One or more walking surfaces within 36 inches (914 mm)
<br />horizontally of the plane of the glazing,
<br />
<br />5. All glazing in railings regardless of area or height above a walking
<br />surface including structural baluster panels and non structural in-fill
<br />panels.
<br />6. Glazing in walls and fences enclosing indoor and outdoor swimming
<br />pools and spas where the bottom edge of the glazing is 1) less than 60 inches
<br />(1525 mm) above the walking surface on the pool side of the glazing, and 2)
<br />the glazing is within 60 inches (1525 mm) horizontally of the water's edge of
<br />a swimming pool or spa. This shall apply to single glazing and all panes in
<br />multiple glazing.
<br />
<br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THE
<br />STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH THE
<br />FLORIDA BUilDING CODE, SECTION 1606 FOR 120 M.P.H. 3 SECOND
<br />GUST, EXPOSURE liB" WIND ZONE (2001 EDITION),
<br />
<br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE
<br />DATE IS SIGNED AND SEALED,
<br />
<br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION OF THIS
<br />DRAWING ONLY.
<br />
<br />o
<br />-.J
<br />--.J
<br />
<br />~
<br />Z
<br />00:::
<br />OW
<br />(J)W
<br />zZ
<br /><!~
<br />Oz
<br />W
<br />
<br />
<br />
<br />o
<br />.-i
<br />Z
<br />o
<br />(J)
<br />0:::
<br />W
<br />>
<br />
<br />10
<br />o
<br />o
<br />N (J)
<br />~ Z
<br />~ 0
<br />~ (J)
<br />~ >
<br />o W
<br />u.J 0:::
<br />::J
<br />[f)
<br />(j)
<br />
<br />W
<br />lJ... :2: CJ::
<br />w"0~t2
<br />W ~w~~
<br />\oJ :2:90::::)
<br />I- x~CJ::o
<br />o ::l lJ... 8
<br />o ifoz~
<br />Z ~02~f-
<br />L.lJ CJ:: ~ ~
<br />W CJ::lJ... L.lJ
<br />~ 8~~g
<br />~ 5~~~
<br />O ::::) W Ui L.lJ
<br />a CJ:: -I :2:
<br />O(/)~~
<br />u.. ~~~g
<br />W ~20o
<br />0::: ~~~~
<br /><! w~ffig
<br />::::) ~ 0 ~ co
<br />:J ....J - ~
<br />CYO'....Juio
<br />(/) (/) ~ ....J .......
<br />....J W ....J 0
<br />~ ~ ~ ~
<br />
<br />Cf)
<br />.....J
<br />.....J
<br />
<br />-
<br />
<br />:c
<br />
<br />>-a5
<br />0::-
<br />0>
<br />......1-
<br />ZCf)
<br />wW
<br />>0:::
<br />zO
<br />-0
<br />~~O ~
<br />0) ~ ~
<br />o 0 ill
<br />000
<br />I.....JD:::
<br />~ CO 8
<br />I~O
<br />~(j)~
<br />~.-8
<br />L.() 0 Z
<br />~ .....J S
<br />
<br />LO
<br />o
<br />o
<br />r-:N
<br />lJ...u '
<br />o UJ c:::i
<br />~a ~
<br />ffi if ~
<br />Cl.. (/) I:
<br />fi I ~
<br />Cl.. f- Cl..
<br />~6 ~
<br />Q~ ~
<br />w~ ::::)
<br />I ~ ~d 53
<br />()u..; ww~
<br />L5 CJ:: I: CJ::
<br />CO ~f-o
<br />(/) 0 I:
<br />O(Ocozzt-
<br />-.J(Oq(!l~~
<br />-.J..-iO)Uiuz
<br />o Ol.C) w....J::::)
<br />a..l.C)NO-:Cl::
<br /><(q.....O(!lO
<br />,(O_zzz
<br />o_()~i'2o
<br />010 (/)~i=
<br />q..-i ~z u
<br />I0CO ~-::l
<br />'-" ~(!lO
<br />><, ~f5fi
<br />g~ oo[b
<br />. 0 ~~ Ct:
<br />OI wZ>-
<br />0.: a.. ~ c3 ~
<br />(0
<br />
<br />NCO
<br />1'-0)
<br />lO(O
<br />~O)
<br />,l.C)
<br /><(q
<br />0(0
<br />0::",
<br />O..-i
<br />-.Jco
<br />IJ... '-"
<br />
<br />l.!) 00 ('oj
<br />'<t L!) ('oj
<br />('oj f"... ~
<br />'<t 0) 0
<br />(V) '<t to
<br />W W lJ..J
<br />a.: a.. a.:
<br />
<br />~
<br />Q)
<br />..0
<br />C
<br />Q) c
<br />Q) 0 ..c
<br />.... rJ') c
<br />~ c >-
<br />::J
<br />~ ~ I
<br />Q) -r-
<br />::J -. .......
<br />
<br />~ .~ l
<br />'~DD
<br />
<br />
<br />(Y)
<br />o
<br />o
<br />N
<br />o
<br />~
<br />o
<br />w LL
<br />~ ><
<br /><t: 0
<br />z
<br />z
<br /><t:
<br />-..J
<br />0...
<br />
<br />SHEET NO.
<br />
<br />8-8
<br />
<br />LAST PLOT
<br />DATE:Apri115,2005
<br />
<br />o
<br />'<T
<br />~
<br />..--
<br />I
<br />0)
<br />o
<br /><DI'-
<br />C"">I'-
<br />C"">N
<br />-.J1i'>
<br />lLcr,
<br />.<D
<br /><t:1'-
<br />0..'
<br />~~
<br /><t:'9
<br />I-~
<br />
<br />z
<br />o.
<br />-0
<br />f!?>
<br />>-.J
<br />-co
<br />Ow
<br /><t:D:::
<br />go
<br />D:::I
<br />OU)
<br />-.JI-
<br />lLU)
<br />-.Jwo
<br />~5:g
<br />I- z'w
<br />z I-
<br />wOS
<br />uft5U)
<br />
<br /> 0::0.:
<br /> wO::
<br />W zO
<br />zU
<br /> <(w
<br />0 ~~
<br />>-0
<br /> z:Z:
<br />~ <((J')
<br />=>
<br />z
<br />0 -~
<br />00
<br />Z ~fE
<br />=>f-
<br /> Oz
<br />~ Ow
<br />O::(J')
<br />o..zz
<br />:r: woo
<br />O::u-
<br />(!J wz~
<br />a::lw~
<br /> bl=O
<br />0::: zCi::<(
<br />>-39
<br />>- <(wO::
<br />~::cg
<br />a.. zf-IJ...
<br />:5f-...J
<br />0 o..g~
<br />~~~
<br />0 ::c-w
<br />f-3u
<br />
<br />c..
<br />CI:
<br />o
<br />()
<br />w
<br />:2:
<br />o
<br />:r:
<br />(/)
<br />::J
<br />l.C)
<br />8
<br />N
<br />
<br />@)
<br />
<br />NOTE: IT IS THE CONTRACTORS RESPO'iSIBIU1Y TO REVIEW ALL
<br />DRAWINGS BER)RE CONSTRUCTION BEGINS. DANSCO
<br />ENGINEERING, LLC IS RESPONSIBLE R)R THE STRUCTURAL
<br />INTEGRITY OF THIS PROJECT O'iL y, ANY DISCREPANCY BETWEEN
<br />FIELD CONDITIONS. OTHER DESIGN PROFESS!OMLS' SI-IOP DRAWINGS,
<br />CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED
<br />DRAWII'.GS MUST BE BROUGHT TO THE ATTENTION OF DANSCO
<br />E'JGINEERING, LLC PRIOR TO THE COMMENCE:.MENT OF CONSTRUCTION.
<br />
<br />
<br />~
<br />"
<br />/
<br />/
<br />I
<br />I
<br />I
<br />I
<br />I
<br />,
<br />r
<br />I
<br />\
<br />\
<br />\
<br />
<br />\ 'APR 1 8 2005
<br />,
<br />,
<br />,
<br />,
<br />
<br />~
<br />~
<br />.......-----'
<br />
<br />,
<br />,
<br />,
<br />,
<br />,
<br />,
<br />\
<br />\
<br />\
<br />I
<br />I
<br />,
<br />,
<br />I
<br />I
<br />I
<br />I
<br />/
<br />/
<br />/
<br />"
<br />~
<br />
<br />PLACE SEAL HERE DE #250989
<br />
|