<br />STRUCTURAL NOTES:
<br />
<br />TERMITE SPECIFICATIONS:
<br />
<br />GENERAL NOTES:
<br />
<br />STRUCTURAL DESIGN CRITERIA
<br />
<br />UJ
<br />~o:::
<br />UJ' ~ ~ t2
<br />W ~UJ I-
<br />........ ~o~z
<br />I- -Vi05
<br />O ~~tEu
<br />o:::oz~
<br />Z lS:~~1-
<br />~O<l:O
<br />LJ..J UJtEf-'z
<br />~ ~z~o
<br />_ oUJ<l:o
<br />-.... UJ~(/')O
<br />I- I-<l:-z
<br />O 01-6<1:
<br />~UJ-UJ
<br />o O'o:::(/')~
<br />u.. (/)~t5~ .
<br />UJ(/) o:::Z
<br />0Z~LLQ
<br />LJ..J ~QOo~
<br />0::: o(/)O:::I-u
<br />_ OZO~-
<br />........ LLUJiiUO:
<br />::> UJ~UJg~
<br />a ~O~CO-.J
<br />U) ~-.J-o:::-.J
<br />g~1~~
<br />:J~~~O:::
<br /><1:0;><1:0
<br />
<br />FOUNDATIONS
<br />SOIL TO BE COMPACTED TO AT LEAST 95%
<br />OF MAX. DRY DENSITY AS DETERMINED BY
<br />ASTM - 1557 ( MODIFIED PROCTOR)
<br />
<br />FOUNDATION INSPECTIONS
<br />A FOUNDATION SURVEY SHALL BE PERFORMED AND A
<br />COPY OF THE SURVEY SHALL BE ON SITE FOR THE BUILDING
<br />INSPECTORS USE, OR ALL PROPERTY MARKERS SHALL BE
<br />EXPOSED AND A STRING STRECHED FROM MARKER TO
<br />MARKER TO VERIFY REQUIRED SETBACKS.
<br />
<br />CAST IN PLACE CONCRETE
<br />1. ALL CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE
<br />STRENGTH AT 28 DAYS OF 3000 PSI, A SLUMP OF 6"
<br />PLUS OR MINUS 1", AND HAVE 2 TO 5% AIR ENTRAINMENT,
<br />AND A MAXIMUM WATERICEMENT RATIO OF 0.63
<br />2. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC
<br />DEFORMED BILLET STEEL CONFORMING TO ASTM A-615
<br />GRADE 40,
<br />3. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185.
<br />WNF SHALL BE LAPPED AT LEAST 6" AND CONTAIN AT
<br />LEAST ONE CROSS WIRE WITHIN THE 6".
<br />4. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF
<br />ALL TOP BARS OF BEAMS.
<br />5. HORIZONTAL FOOTING BARS SHALL BE BENT 1'-0"
<br />AROUND CORNERS OR CORNER BARS WITH A 2'-0"
<br />LAP PROVIDED
<br />6. MINIMUM LAP SPLICES ON ALL REINFORCING BAR
<br />SPLICES SHALL BE 40 BAR DIAMETERS TYP.
<br />7. CONCRETE COVER MIN. 3" WHEN EXPOSED TO EARTH OR
<br />11/2" TO FORM
<br />MASONRY WALL CONST.
<br />1. HOLLOW LOAD BEARING UNITS SHALL BE NORMAL
<br />WEIGHT, GRADE N, TYPE 2, CONFORMING TO ASTM C90,
<br />WITH A MINIMUM NET COMPRESSIVE STRENGTH OF
<br />1900 PSI ( f'm == 1500 PSI)
<br />2. MORTAR SHALL BE TYPE "M" OR "S", CONFORMING TO
<br />ASTM C270.
<br />3. COARSE GROUT SHALL CONFORM TO ASTM C476 WITH A
<br />MAXIMUM AGGREGATE SIZE OF 3/8" AND A MINIMUM
<br />COMPRESSIVE STRENGTH OF 3000 PSI SLUMP 8" TO 11",
<br />4. VERTICAL REINFORCEMENT SHALL BE AS NOTED ON THE
<br />DRAWINGS WITH THE CELLS FILLED WITH COARSE GROUT.
<br />5. VERTICAL REINFORCEMENT SHALL BE HELD IN POSITION
<br />AT THE TOP AND BOTTOM AND AT A MAXIMUM SPACING
<br />OF 192 BAR DIAMETERS, REINFORCEMENT SHALL BE PLACED
<br />IN THE CENTER OF THE MASONRY CELL TYPICAL UNLESS
<br />OTHERWiSE NOTED.
<br />6. REINFORCING STEEL SHALL BE LAPPED A MINIMUM OF 40 BAR
<br />DIAMETERS, UNLESS OTHERWISE NOTED ON THE DRAWINGS
<br />7. DUR-D-WALL SHALL BE PROVIDED @ EVERY OTHER
<br />COARSE OR 16" OIC
<br />
<br />WOOD CONSTRUCTION
<br />
<br />FLORIDA BUILDING CODE, 2001 EDITION
<br />BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI 318-02)
<br />SPECIFICATIONS FOR STRUCTURAL CONCRETE BUILDINGS (ACI 301-89)
<br />BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02)
<br />NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION, 2001 EDITION
<br />APA PLYWOOD DESIGN SPECIFICATION
<br />
<br />CODES:
<br />
<br />1. A PERMANENT SIGN WHICH IDENTIFIES THE TERMITE TREATMENT PROVIDER
<br />AND NEED FOR RE-INSPECTION AND TREATMENT CONTRACT RENEWAL SHALL
<br />BE PROVIDED. THE SIGN SHALL BE POSTED NEAR THE WATER HEATER OR
<br />ELECTRIC PANEL.(FBC 104,2.6)
<br />
<br />2. CONDENSATE AND ROOF DOWl\<SPOUTS SHALL DISCHARGE AT LEAST 1'-0"
<br />AWAY FROM BUILDING SIDE WALKS.(FBC 1503.4.4)
<br />
<br />3. IRRIGATION/SPRINKLER SYSTEMS INCLUDING ALL RISERS AND SPRAY HEADS
<br />SHALL NOT BE INSTALLED WITHIN 1'-0" OF THE BUILDING SIDE WALLS,(FBC 1503.4.4)
<br />
<br />4. TO PROVIDE FOR INSPECTION FOR TERMITE INFESTATION, BETWEEN WALL
<br />COVERING AND FINAL EARTH GRADE SHALL NOT BE LESS THAT 6 INCHES.
<br />
<br />EXCEPTION: PAINT OR DECORATIVE CEMENTATIOUS FINISH LESS THAN 5/8"
<br />THICK ADHERED DIRECTLY TO THE FOUNDATION WALL.(FBC 1403.1.6)
<br />
<br />PREFABRICATED WOOD TRUSSES
<br />
<br />1. ALL PREFABRICATED WOOD TRUSSES SHALL BE SECURELY
<br />FASTENED TO THEIR SUPPORTING WALLS OR BEAMS WITH
<br />HURRICANE CLIPS OR ANCHORS,
<br />2. PREFABRICATE WOOD TRUSSES SHALL BE DESIGNED IN
<br />ACCORDANCE WITH THE LATEST EDITION OF THE "NATIONAL
<br />DESIGN SPECIFICATION FOR STRESS-GRADE LUMBER AND
<br />ITS FASTENERS" AS RECOMMENDED BY THE NATIONAL
<br />FOREST PRODUCTS ASSOCIATION.
<br />
<br />3. TRUSS MEMBERS AND CONNECTIONS SHALL BE PROPOR-
<br />TIONED ( WITH A MAXIMUM ALLOWABLE STRESS INCREASE
<br />FOR LOAD DURATION OF 25%) TO WITHSTAND THE LIVE
<br />LOADS GIVEN IN THE NOTES AND TOTAL DEAD LOAD.
<br />4. BRIDGING FOR PRE-ENGINEERED TRUSSES SHALL BE AS
<br />REQUIRED BY THE TRUSS MANUFACTURER UNLESS
<br />NOTED ON THE PLANS,
<br />5. TRUSS ELEVATIONS AND SECTIONS ARE FOR GENERAL
<br />CONFIGURATION OF TRUSSES ONLY. WEB MEMBERS ARE
<br />NOT SHOWN. BUT SHALL BE DESIGNED BY THE TRUSS
<br />MANUFACTURER IN ACCORDANCE WITH THE DESIGN
<br />LOADS AS LISTED ON THE STRUCTURAL DESIGN CRITERIA
<br />6. DESIGN SPECIFICATIONS FOR LIGHT WEIGHT METAL
<br />PLATE CONNECTED WOOD TRUSSES PER THE TRUSS
<br />PLATE INSTITUTE TPI LATEST EDITION.
<br />7. PRE-ENGINEERED WOOD TRUSSES SHALL BE DESIGNED BY
<br />THE MANUFACTURER IN ACCORDANCE WITH SPECIFIED LOADS
<br />AND GOVERNING CODES. SUBMITTALS SHALL INCLU DE TRUSS
<br />FRAMING PLANS AND DETAILS SHOWI~~G MEMBER SIZES,
<br />BRACING. ANCHORAGE, CONNECTIONS. TRUSS LOCATIONS, AND
<br />AND PERMANENT BRACING AND/OR BRIDGING AS REQUIRED
<br />FOR ERECTION AND FOR THE PERMANENT STRUCTURE. EACH
<br />SUBMITTAL SHALL BE SIGNED AND SEALED BY A FLORIDA
<br />REGISTERED STRUCTURAL ENGINEER, SUBMIT 3 COPIES FOR
<br />REViEW AND APPROVAL PRIOR TO FABRICATION.
<br />8. THE TRUSS MANUFACTURER SHALL DETERMINE ALL SPANS
<br />WORKING POINTS, BEARING POINTS, AND SIMILAR CONDITIONS.
<br />TRUSS SHOP DRAWINGS SHALL SHOW ALL TRUSSES, ALL
<br />BRACiNG MEMBERS, AND ALL TRUSS TO TRUSS HANGERS.
<br />
<br />THE FOUOWING TECHINCAL CODES
<br />SHAll APPLY:
<br />
<br />2001 flORIDA BUilDING CODE,
<br />PLUMBING, MECHANICAL, FUEL GAS,
<br />ENERGY EFFICIENCY, ACCESSIBILITY,
<br />AND 2002 NATIONAL ELECTRICAL CODES
<br />
<br />ROOF
<br />TOP CHORD
<br />BOTTOM CHORD (W/O STORAGE)
<br />RESIDENTIAL FLOOR, UNLESS OTHERWISE INDICATED
<br />BALCONIES
<br />STAIRS
<br />
<br />ROOF
<br />FLOOR
<br />
<br />WIND LOADS BASED ON FBC, SECTION 1606.2.
<br />WIND VELOCITY: 120 M,P,H" USE FACTOR: 1.0
<br />
<br />ALL CONCRETE UNLESS OTHERWISE INDICATED
<br />PEA GRAVEL CONCRETE FOR MASONRY CELLS ONLY
<br />(DO NOT USE FOR CONCRETE COLUMNS OR TIE BEAMS)
<br />
<br />LIVE LOADS:
<br />
<br />20 PSF
<br />10 PSF
<br />40 PSF
<br />40 PSF
<br />40 PSF
<br />
<br />17 PSF (SHINGLE)
<br />15 PSF
<br />
<br />ORDINANCE 92-19 - APPENDIX "J"
<br />TO FBC PLUMBING 2001 CODE,
<br />1. TANK TYPE WATER CLOSET VOLUME
<br />1.6 GALLONS
<br />2. WALL MOUNT WATER CLOSET VOLUME
<br />3.5 GALLONS
<br />3. WATER - FLOW RATE.
<br />PUBLIC FACILITIES 0.5 G,P.M.
<br />PRIVATE FACILITIES 2.2 G.P.M.
<br />SHOWER HEADS 2.5 G,P.M.
<br />4. ALL PLUMBiNG WATER LINES
<br />TO BE PVPC
<br />
<br />DEAD LOADS:
<br />
<br />WIND lOADS:
<br />(F.B.C.)
<br />
<br />5. INITIAL TREATMENT SHALL BE DONE AFTER ALL EXCAVATION AND BACKFILL
<br />IS COMPLETE,(FBC 1816.1.1)
<br />
<br />6. SOIL DISTURBED AFTER THE INITIAL TREATMENT SHALL BE RETREATED
<br />INCLUDING SPACES BOXED AND FORMED,(FBC 1816.1.2)
<br />
<br />7. BOXED AREAS IN CONCRETE FLOORS FOR SUBSEQUENT INSTALLATION OF TRAPS,
<br />ETC., SHALL BE MADE WITH PERMANENT METAL OR PLASTIC FORMS. PERMANENT
<br />FORMS MUST BE OF A SIZE AND DEPTH THAT WILL ELIMINATE THE DiSTURBANCE OF
<br />SOIL AFTER THE INITIAL TREATMENT.(FBC 1816,1.3)
<br />
<br />8. MINIMUM 6 MIL VAPOR RETARDER MUST BE INSTALLED TO PROTECT AGAINST RAINFALL
<br />DILUTION. IF RAINFALL OCCURS BEFORE VAPOR RETARDER PLACEMENT. RETREATMENT IS
<br />REQUIRED.(FBC 1816,1.4)
<br />
<br />9. CONCRETE OVERPOUR AND MORTAR ALONG THE FOUNDATION PERIMETER MUST BE
<br />REMOVED BEFORE EXTERIOR SOIL TREATMENT,(FBC 1816.1.5)
<br />
<br />10. SOIL TREATMENT MUST BE APPLIED UNDER ALL EXTERIOR CONCRETE OR GRADE
<br />WITHIN 1'-0" OF THE STRUCTURE SIDEWALLS.(FBC 1816.1.6)
<br />
<br />11. AN EXTERIOR VERTICAL CHEMICAL BARRIER MUST BE INSTALLED AFTER CONSTRUCTION
<br />IS COMPLETE INCLUDING LANDSCAPING AND IRRIGATION, ANY SOIL DISTURBED AFTER
<br />THE VERTICAL BARRIER IS APPLIED, SHALL BE RETREATED.(FBC 1816.1.6)
<br />
<br />12. ALL BUILDINGS ARE REQUIRED TO HAVE PRE-CONSTRUCTION TREATMENT.(FBC 1816,1.7)
<br />
<br />13. A CERTIFICATE OF COMPLIANCE MUST BE iSSUED TO THE BUILDING DEPARTMENT
<br />BY A LICENSED PEST CONTROL COMPAI\iY BEFORE A CERTIFICATE OF OCCUPANCY
<br />WILL BE ISSUED. THE CERTIFICATE OF COMPLIANCE SHALL STATE: "THE BUILDING
<br />HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN
<br />TERMITES. THE TREATMENT IS IN ACCORDANCE WITH THE RULES AND LAWS OF THE
<br />FLORIDA DEPARMENT OF AGRICULTURE AND COI\iSUMER SERVICES,"(FBC 1816,1.7)
<br />
<br />14. AFTER ALL WORK is COMPLETED, LOOSE WOOD AND FILL MUST BE REMOVED FROM
<br />BELOW AND WITHIN 1'-0" OF THE BUILDING. THIS INCLUDES ALL GRADE STAKES,
<br />TUB TRAY BOXES, FORMS. SHORING OR OTHER CELLULOSE CONTAINING MATERIAL.
<br />(FBC 2303.1.3)
<br />
<br />15. NO WOOD, VEGETATION, STUMPS, CARDBOARD. TRASH, ETC., SHALL BE BURIED
<br />WITHIN 15'-0": OF ANY BUILDING OR PROPOSED BUILDING.(FBC 2303.1.4)
<br />
<br />3000 PSI
<br />3000 PSI
<br />
<br />CONCRETE
<br />STRENGTH
<br />@ 28 DAYS
<br />
<br />('f)
<br />o
<br />o
<br />~ (j)
<br />c;J Z
<br />..-i 0
<br />..-i
<br />W (j)
<br />!;:( >
<br />o W
<br />~ 0::
<br />U)
<br />IJ"J
<br />
<br />o
<br />~
<br />Z
<br />o
<br />(j)
<br />0::
<br />W
<br />>
<br />
<br />VTR LOCATIONS ARE APPROXIMATE
<br />AND MAY CHANGE DUE TO JOBSITE
<br />CONDITIONS
<br />
<br />THE FOLLOWING SHALL COMPLY
<br />WITH THE 2001 mc,
<br />
<br />o PORCHES AND BALCONIES
<br />SECTION 1014
<br />o HANDRAILS - SECTION 1007.5
<br />o GUARDRAILS - SECTION 1015, 1019.9
<br />o STAIRS - SECTION 1007
<br />o CHIMNEY & FIREPLACE
<br />SECTION 2804-2806 (MFGR)
<br />SECTION 2113-2114 (MAS)
<br />o EGRESS WINDOWS
<br />SECTION 1005.4
<br />
<br />ASTM A185
<br />ASTM A615-40 40,000 PSI
<br />ASTM A615-40 40,000 PSI
<br />
<br />WELDED WIRE FABRIC SHALL CONFORM TO
<br />ALL REINFORCING BARS
<br />ALL STIRRUPS AND TIES
<br />
<br />ASTM C90 OR C129, STANDARD WEIGHT UNITS, fm==1500 PSI
<br />MORTAR TYPE "S" 1900 PSI
<br />CONCRETE GROUT 3000 PSI
<br />CONTINUOUS MASONRY INSPECTION is REQUIRED DURING CONSTRUCTION
<br />
<br />ALL STRUCTURAL AND MISCELLANEOUS STEEL A36 36,000 PSI, U.N.O
<br />SHOP AND FIELD WELDS: E70XX ELECTRODES
<br />ALL BOLTS CAST IN CONCRETE: ASTM A36 OR ASTM A-307
<br />
<br />REINFORCING:
<br />
<br />CONCRETE
<br />MASONRY
<br />UNITS:
<br />
<br />U) 00 N
<br />"<::t U) N
<br />N I'- ~
<br />"<::t (J) 0
<br />('I) "<::t c.o
<br />W W W
<br />0- 0- 0..
<br />
<br />STRUCTURAL
<br />STEEL:
<br />
<br />BEAMS, RAFTERS, JOIST, PLATES, ETC. U.N.O.
<br />NO.2 SOUTHERN YELLOW PINE (19% M.C.)
<br />ROOF DECK: PLYWOOD C-C/C-D, EXTERIOR, or OSB
<br />FLOOR SHEATHING: 3/4" PLYWOOD (5 PLIES) OR 3/4" T&G ADVANTECH
<br />WALL SHEATHING: PLYWOOD C-C/C-D, EXTERIOR OR OSB
<br />VERSA LAM BEAM Fb == 2900 PSI (2.0E)
<br />
<br />WOOD FRAMING:
<br />
<br />
<br />~
<br />(!)
<br />..n
<br />c
<br />~ c .c
<br />"- 0 c
<br /><.9 rJ) >.
<br />C :J
<br />ct ~ I
<br />(!) ~ I
<br />:J
<br />E .~ ~
<br />
<br />i~~
<br />
<br />4. ALL OPENINGS SHALL COMPLY WITH
<br />2001 FBC WIND LOADS AS STATED
<br />BELOW. ATTACHMENTS OF WINDOWS,
<br />DOORS, SLIDING GLASS DOORS
<br />AND O.H. GARAGE DOORS ARE TO DELEGATED
<br />THE MANUFACTURER OF THESE ITEMS. THE
<br />MANUFACTURER OF THESE ITEMS
<br />SHALL SUBMIT ATTACHMENTS FOR
<br />SITE INSTALLATION,
<br />
<br />SEE ATTACHED SPECIFICATION SHEETS FOR
<br />MANUFACTURERS DESIGN CRITERIA AND
<br />INSTALLATION METHODS FOR WINDOWS,
<br />DOORS, SLIDING GLASS DOORS, OVERHEAD
<br />GARAGE DOORS, AND ROOFING.
<br />
<br />UPLIFT CONNECTORS
<br />
<br />DESIGN LOADS:
<br />TOP CHORD LIVE AND DEAD LOAD:
<br />BOTTOM CHORD LIVE AND DEAD LOAD:
<br />TOTAL:
<br />
<br />WOOD ROOF
<br />TRUSSES:
<br />
<br />27 PSF
<br />20 PSF
<br />47 PSF
<br />
<br />1. UPLIFT CONNECTORS SUCH AS HURRICANE CLIPS, TRUSS
<br />ANCHORS AND ANCHOR BOLTS ARE ONLY REQUIRED ON
<br />MEMBERS IN WALLS THAT ARE EXPOSED TO UPLIFT FORCES.
<br />INTERIOR LOAD BEARING WALLS ARE NOT ALWAYS EXPOSED
<br />TO UPLIFT FORCES. THE MEMBERS OF THESE WALLS WOULD
<br />NOT NEED TO HAVE CONNECTORS APPLIED. PLEASE CONSULT
<br />THE TRUSS ENGINEERING FOR THE LOCATION OF THESE WALLS.
<br />
<br />NET UPLIFT DESIGN PRESSURE: 20 PSF WITHIN
<br />4 FEET OF RIDGES, HIPS, EAVES AND BUILDING
<br />PERIMETER AND 15 PSF MIN FOR ALL OTHER AREAS.
<br />
<br />SEE DRAWINGS FOR SPECIAL CONCENTRATED LOADS. DESIGN
<br />FOR NEW WIND UPLIFT AS PER SPECIFIED CODES. DEDUCTING
<br />A MAXIMUM OF 10 P.S.F. DEAD LOAD, BUT NOT EXCEEDING ACTUAL
<br />DEAD LOAD.
<br />
<br />
<br />o
<br />"'"
<br />.,....
<br />.,....
<br />,
<br />0)
<br />o
<br />(01'--
<br />(,,}I'--
<br />("}l;'.j
<br />-.Ji.Q
<br />LLO)
<br />.(0
<br /><(I'--
<br />0..'
<br />~~
<br />
<br />~~
<br />
<br />FIELD REPAIR NOTES
<br />
<br />DESIGN LOADS:
<br />DEAD LOAD:
<br />LIVE LOAD:
<br />TOTAL:
<br />
<br />1. WOOD CO,,"STRUCTION SHALL CONFORM TO THE NFPA
<br />"NATIONAL DESIGN SPECIFlCATION FOR WOOD 1. MISSED LINTEL STRAPS FOR MASONRY CONSTRUCTION MAY
<br />CONSTRUCTION", 2001 EDITION. BE SUBSTITUTED WI (1) "SIMPSON MTSM16 TWIST STRAP WI
<br />2. ALL EXTERIOR WOOD STUD WALLS, BEARING WALLS, SHEAR (4) 1/4" X 21/4" DIA. TITENS TO THE BOND BEAM BLOCK
<br />WALLS AND MISC. STRUCTURAL WOOD FRAMING MEMBERS, AND (7)10d TO THE TRUSS FOR UPLIFTS OF 1000 LBS. OR
<br />( I.E. BLOCKING OR GABLE END BRACING) SHALL BE EITHER LESS. USE (2) FOR 2000 LBS. OR LESS. OTHERS MAY BE
<br />SOUTHERN PINE, OR S.P.F. NUMBER 2 GRADE SHALL BE SUBSTITUTED ON A CASE BY CASE BASIS.
<br />USED REGARDLESS OF SPECIES. 2. MISSED "J" BOLTS FOR WOOD BEARING WALLS MAY BE SUB-
<br />3. Al\<Y WOOD FRAME BEARING WALL STUDS THAT ARE CUT STITUTED WI 1/2" DIA. ANCHOR BOLTS SET IN 3/4" DIA. X 6"
<br />FOR PLUMBING LINES, ETC. SHALL BE REPAIRED WITH DEEP UNITEX "PROPOXY" 300 ADHESIVE BINDER FOLLOWiNG
<br />SIMPSON HSS2 STUD SHOES,TYP., U,N.O. ALL MANUFACTURERS RECOMMENDATIONS ( OR 1/2" X 6"
<br />4. ALL STUCCO FINISH OVER EXTERIOR FRAME MUST BE 7/8" THICK RAWL STUD EXPANSION ANCHORS. )
<br />PER ASTM C. 926-APPLY 3 LAYERS WITH TOTAL THICKNESS 7/8" 3. REGARDING MISSED REBAR IN VERTICAL FlLLED CELLS:
<br />OVER METAL LATH, DRILL A 3/4" DIAMETER HOLE 6" DEEP AT THE LOCATION OF
<br />FIRST 2 LAYERS 3/8" THICK EACH. 3RD LAYER 1/8" THICK. THE OMITTED REBAR, AND INSTALL A 32" LONG #5 BAR INTO
<br />
<br />5. ALL EXPOSED WOOD OR WOOD IN CONTACT WITH THE EPOXY FILLED HOLE. USE A TWO PART EMBEDDEMENT
<br />EARTH OR CONCRETE TO BE PRESSURE TREATED. EPOXY (SIMPSON "EPOXY TIE SET", OR HILTI " 2 PART"
<br />. EMBEDDMENT EPOXY), MIXED PER MANUFACTURER'S
<br />*ATTENTION: CHEMICAL CHANGES IN PRESSURE TREATED WOODS INSTRUCTIONS. ASSURE THAT ALL DUST AND DEBRIS FROM
<br />AS OF DECEMBER 31ST, 2003, CHROMATED COPPER ARSENATE DRILLING ARE REMOVED FROM THE HOLE BY BRUSHING AND
<br />(CCA-C) WILL NO LONGER BE PRODUCED FOR RESIDENTIAL OR AND USING COMPRESSED AIR PRIOR TO APPLYING THE EPOXY,
<br />GENERAL CONSUMER USE. SEVERAL NEW PRESSURE TREATED ALLOW THE EPOXY TO CURE TO MANUFACTURER'S SPECIFICATIONS,
<br />WOOD ALTERNATIVES HAVE BEEN CREATED TO REPLACE CCA-C. THEN FILL THE CELL IN THE NORMAL WAY DURING BOND BEAM
<br />MANY OF THE NEW PRESSURE TREATED WOODS USE CHEMICALS POUR.
<br />THAT ARE CORROSIVE TO STEEL. IT IS THE CONTRACTOR'S 4. HURRICANE STRAPS MAY BE SUBSTITUTED WITH A STRAP OF
<br />RESPONSIBILITY TO VERIFY THE TYPE OF WOOD TREATMENT AND TO GREATER HOLDOWN VALUE OR GREATER UPLIFT VALUE IN THE
<br />SELECT APPROPRIATE CONNECTORS THAT RESiST CORROSION. FIELD WITHOUT VERIFICATION, PROVIDED ALL MANUFACTURERS
<br />FOR EXAMPLE, ACQ-C, ACQ-D, CBA-A, OR CA-B REQUIRE HOT-DIPPED INSTALLATION INSTRUCTIONS ARE FOLLOWED.
<br />GALVANIZED OR STAINLESS STEEL FASTENERS. 5. FOR MORTAR JOINTS LESS THAN 1/4", PROVIDE (1) #5 VERT.
<br />DOT SODIUM BORATE (SBX) DOES NOT. IN CONC. FILLED CELL EACH SIDE OF THE JOINT ( BAR DOES
<br />WOOD FRAMING INSPECTION NOT HAVE TO BE CONT. TO FOOTING)
<br />
<br />ALL PLUMBING, ELECTRICAL, AND MECHANICAL
<br />ROUGH-INS MUST BE COMPLETE, INSPECTED
<br />AND APPROVED BEFORE REQUESTING FRA\I1ING
<br />INSPECTION.
<br />
<br />WOOD flOOR
<br />TRUSSES:
<br />
<br />5, ALL DOORS INTERIOR & EXTERiOR ARE
<br />6'-8" UNLESS OTHERWISE NOTED
<br />ALL SHOWER ENCLOSURES TO BE
<br />TEMPERED GLASS
<br />6. ALL WINDOWS WITHIN 24" OF DOORS
<br />(INTERIOR & EXTERIOR) AND WITHIN
<br />18" OF FLR TO BE TEMPERED GLASS,
<br />(SECTION 2405.2)
<br />
<br />15 PSF
<br />40 PSF
<br />55 PSF
<br />
<br />ASSUMED ALLOWABLE SOIL BEARING PRESSURE AFTER COMPACTION: 2000 PSF
<br />SEE SOILS REPORT AND SPECIFICATIONS FOR COMPACTION REQUIREMENTS
<br />IF SOIL CONDITIONS IN THE PROJECT DO NOT MEET OR EXCEED THE CAPACITY
<br />THE GENERAL CONTRACTOR SHALL CONTACT THE ENGINEER PRIOR TO
<br />FOUNDATION POUR FOR VERIFICATION OF FOUNDATION DESIGN.
<br />
<br />SOil BEARING
<br />VALUE:
<br />
<br />ALL WORK SHALL COMPLY WlTHALL ,.,
<br />PREVAILING CODES, FLORIDA BUlLDlN J
<br />CODE. NATtONAL ELECTRIC CODE ~ND
<br />CITY OF ZliPHYRHlLLS ORDINANCES
<br />
<br />'~
<br />
<br />~
<br />
<br />BUILDING DATA
<br />
<br />INDEX OF DRAWINGS
<br />
<br />SHT NO:
<br />
<br />TITLE
<br />
<br />CONSTRUCTION rlPE - TYPE VI U;'\PROTECTED
<br />(SECTION 608 - FBC 2001)
<br />
<br /> z
<br /> o.
<br /> -0
<br /> ~>
<br /> >-.J
<br /> -co
<br /> Ow
<br /> <(~
<br /> 90
<br /> ~I
<br /> (/) AU)
<br /> -.JI-
<br /> LL(/)
<br /> -.Jwo
<br /> --I ~~g
<br /> I-Zw
<br /> --I zoC:
<br /> Wo:J
<br /> - O(OIJ"J
<br /> :c
<br />>- S
<br />l.LJ
<br />0::: - 0:::0..
<br />> (V) wO:::
<br /> zO
<br />0 0 z()
<br />J- ctW
<br /> ~~
<br />J- 0 LJ..J rO
<br />(/) z::C
<br />Z C\J () ctIJ"J
<br /> ~
<br />l.LJ z
<br /> -~
<br />l.LJ I- 00
<br /> 0 wcr::
<br />0::: 0 ()LL
<br />> er:: ~I-
<br /> 02
<br />() Z Ow
<br /> o:::(/')
<br />Z 0 I- o..ZZ
<br /> woo
<br /> u.. 0:::0-
<br />- 0 :r: wz::~
<br /> >< cow>
<br /> ~ f-1=15
<br />"0 UJ 0 O-ct
<br /> Zo:::
<br />~~ ~ 0::: >-~9
<br />~ ctwO:::
<br /> ~IO
<br />Z >- Zf-cC
<br /> 0... :)f--.J
<br />0 () Z :J~
<br /> 0..00:::
<br />~ 0 (/')I~
<br />...J S:!::u.J
<br />0 0 0... () f-~U
<br />I --l HEET NO, a..
<br />C\J cr::
<br /> 0
<br />CO ()
<br />L() w
<br /> A ~
<br /> 0
<br />I ~ J:
<br />l"- (/')
<br /> :J
<br />0) tr)
<br />~ 0
<br /> 0
<br /> ('\J
<br />~ J- LAST PLOT DATE @
<br />April 15, 2005
<br />L() 0 COVER SHEET
<br />~ --l DE #250990
<br />
<br />WIND SPEED 120 MPH
<br />WIND IMPORTANCE FACTOR - (Iw) == 1.0
<br />WIND EXPOSURE - "B" (FBC 1606,1.8)
<br />INTERNAL PRESSURE COEFFlCIENT = +1- 0.18 (ENCLOSED SLDG)
<br />
<br />REVIEWED
<br />HAY 0 6 2005
<br />
<br />A
<br />1
<br />1A
<br />2
<br />3
<br />4
<br />S-1
<br />S-2
<br />S-2A
<br />S-3
<br />S-4
<br />S-6
<br />5-7
<br />
<br />COVER SHEET
<br />FLOOR PLAN
<br />DIMENSION FLOOR PLAN
<br />STEM FOUNDATION PLAN
<br />ELECTRICAL PLAN
<br />ELEVATION PLAN (III)
<br />STEM FOUNDATION DET.
<br />LINTEL DETAILS
<br />LINTEL PLANS
<br />ROOF FRAMING (III)
<br />GABLE DETAILS (III)
<br />STEM WALL SECTIONS
<br />STRUCTURAL NOTES &
<br />HANGER INFORMATION
<br />STRUCTURAL NOTES &
<br />HANGER INFORMATION
<br />WINDOW & DOOR DETAILS
<br />ROOF INSTALLATION DET
<br />ROOF INSTALLATION DET
<br />MILESTONE WINDOW DET.
<br />MILESTONE SGD DET.
<br />STD. GARAGE DETAILS
<br />FL PRODUCT APPROVAL
<br />
<br />
<br />
<br />WIND BORNE DEBRIS AREAS
<br />
<br />DESIGN WIND PRESSURE:
<br />(COMPONENT AND CLADDING) WORST CASE (10 SF - END ZONE)
<br /># END ZONE IS ONLY WITHIN 5'-D"
<br />OF ALL EXTERIOR BUILDING CORNERS
<br />
<br />~bwr
<br />
<br />TO SATISFY PROTECTION OF OP GS
<br />IBILlTY
<br />
<br />WINDOWS AND DOORS
<br />120 MPH + 25,9 PSF I - 34.7 PSF (END)
<br />+ 25.9 PSF/-28.1 PSF (INTERIOR) U.N.O.
<br />
<br />GARAGE DOORS (V = 120 MPH)
<br />SINGLE 9x7 +25 PSF I -32.0 PSF
<br />DOUBLE 16x7 +24 PSF I -24.5 PSF
<br />
<br />SEE ElEVATION PAGE FOR ACTUAL PRESSURES
<br />
<br />
<br />GLAZING
<br />B.APPROVE TTERS
<br />C. SUppl OOD STRUCTURAL PANELS
<br />BC 1606.1.4
<br />
<br />MASTER REVISIONS
<br />
<br />
<br />S-7A
<br />
<br />DESCRIPTION
<br />
<br />DATE
<br />
<br />5-8
<br />S-8.1
<br />S-8.1A
<br />S-9M
<br />S-10M
<br />S-11
<br />SFPA
<br />
<br />ENGINEERED PLANS
<br />ON FILE
<br />
<br />f n.... p' f 't"~; . ">:~;;;>':)fi
<br />tt~.-......,;;- .' '.}.~;::.; :.. .'~ l~. ro' ....~.,..
<br />:",---' ~'fi-'" r ;""~. f' ." w
<br />
<br />'.n;.,;;c~-,1i~ \ ::>;;1~;:.tg;/.r?~.
<br />'. o~ . ,..t.,.,,,, '.'..
<br />
<br />
<br />CENTRAL FLORIDA DIVISION
<br />600 N. WESTSl-iORE BLVD.
<br />SUITE 600
<br />
<br />NOTICE TO BUILDER
<br />
<br />TAMPA, FL 33609-1140
<br />1-813-769-5277
<br />
<br />IT is THE INTENT OF THIS DESIGNER THAT
<br />THESE PLANS ARE ACCURATE AND ARE
<br />CLEAR ENOUGH FOR THE LICENSED PROFESS-
<br />ONAL TO CONSTRUCT THIS PROJECT,
<br />IN THE EVENT THAT SOMETHING IS UNCLEAR
<br />OR NEEDS CLARIFICATION"STOP..AND CALL
<br />THE DESIGNER LISTED IN THIS TITLE PAGE. IT
<br />is THE RESPONSIBILITY OF THE LICENSED
<br />PROFESSIONAL THAT is CONSTRUCTING THIS
<br />PROJECT TO FULLY REVIEW THESE DOCUMENTS
<br />BEFORE CONSTRUCTION BEGINS AND ANY AND
<br />ALL CORRECTIONS, IF NEEDED, TO BE MADE
<br />BEFORE ANY WORK IS DONE,