<br />r
<br />
<br />INSTALLATION OF WINDOW
<br />BUCK STRIPS - lx3 (MINL GLUE
<br />STRIP W/ADHESIVE SEALANT
<br />& SCREW Wj3/16" x 2 1/2" PHILLI
<br />FLAT HD. "TAPtON" SCREW MIN.
<br />4" FROM END & 16" O.C.
<br />
<br />
<br />EXT. FINISH
<br />DRIP EDGE
<br />INSTALLATION OF S.G.D.
<br />BUCK STRIPS - lx4 (MIN). GLUE
<br />STRIP W/ADHESIVE SEALANT
<br />& SCREW W/3/16" x 2 1/2"
<br />PHILLIPS FLAT HD. "TAPCON"
<br />SCREW MIN. 4" FROM END
<br />& 16" O.C.
<br />TRACK - FILL ALL HOLES 9
<br />W/l" x #8 ST. STL. SCREW
<br />W/PLASTIC ANCHORS
<br />SEALANT
<br />
<br />-----
<br />
<br />MASONRY OPENING
<br />S.G.D. INSTALLATION
<br />
<br />SCALE: N.T.S
<br />
<br />BLOCK LINTEL
<br />
<br />1/2" DRWALL
<br />BUCKSTRIP - lX3 MIN (WINDOW)
<br />1/8" SHIM s~dHtMIN (SGD)
<br />WINDOW/SGD
<br />
<br />~~~k'&~ JAM B
<br />11/2" RECESS
<br />IN SLAB
<br />SLIDING GLASS
<br />DOOR
<br />
<br />
<br /> .. TIE BEAM -
<br /> . PRECAST LINTEL -..
<br />(/)
<br />w
<br />0:: FASTEN PT 2X 8 BUCK TO
<br />~
<br />>
<br /> MASONRY W/ 3116" X 3"
<br /> TAPCONS 6" FROM ENDS
<br /> AND 16" O.C. MAX.
<br /> FASTENING WINDOW TO
<br /> BUCK RESPONSIBILTY OF
<br /> WINDOW MANUFACTURER.
<br /> /
<br /> I
<br />
<br />
<br />2 X 8 BUCK DETAIL
<br />
<br />SCALE: N.T.S.
<br />3-15-04 TH
<br />
<br />L
<br />
<br />3
<br />
<br />
<br />2
<br />
<br />TYP. 8" BLOCK WALL
<br />
<br />
<br />1
<br />6" BITUMINOUS TAPE INSTALLATION SEQUENCE
<br />
<br />EXT. FINISH -*1
<br />JAMB - FILL I
<br />ALL HOLES W / I
<br />1-112"X#8 (MIN')I
<br />SCREW
<br />I
<br />
<br />SEALANT
<br />BACK OF ALL
<br />JAMBS
<br />TRACK. FILl:
<br />ALL HOLES WI
<br />1"X#8 (MIN.)
<br />SCREWS WI
<br />PLASTIC ANCH.
<br />
<br />1 X P.T. WI 3/16" X 2 1/4"
<br />TAPCONS @ 18" OIC MAX.
<br />& 6" FROM CORNERS
<br />
<br />
<br />WINDOW HEADER
<br />2 - 2"X12" S,Y,P,
<br />UNLESS OTHERWISE
<br />SPECIFIED
<br />1/2" D.W,
<br />: ------TRIM
<br />
<br />(SEE PLAN)
<br />S,G.D. JAMB
<br />
<br />"-- 3/4" RECESSED
<br />SLAB
<br />SEALANT
<br />
<br />MAS. WALL EXT.DOOR JAMB
<br />
<br />
<br />
<br />SCALE: N.T.S,
<br />
<br />FRM. OPNG. SGD INSTALL
<br />
<br />SCALE: N.T.S.
<br />
<br />
<br />h
<br />
<br />@:
<br />
<br />I
<br />I
<br />I
<br />
<br />~
<br />
<br />@
<br />
<br />@
<br />
<br />~v
<br />
<br />I
<br />
<br />:@
<br />
<br />a: ) 10 PERCENT OF LEAST HORIZONTAL DIMENSION OR OAh, WHICHEVER IS SMALLER, BUT NOT
<br />LESS THAN EITHER 4% OF LEAST HORIZONTAL DIMENSION OR 3 FT ( 1 m).
<br />
<br />COMPONENT & CLADDING DESIGN PRESSURE
<br />(120 MPH, 3 SEC GUST, 2.1/12 PITCH, EXPOSURE B, HEIGHT = 0 TO 30 FEET, IMPORTANCE FACTOR = 1 )
<br /> (PSF)
<br />TRIBUTARY AREA ROOF WALL
<br />(FT2)
<br /> (GCpi = +/- .18) (GCpi = +/- .18)
<br /> ZONE 1 ZON E 2 & 3 ZONE 4 ZONE 5
<br />10 14.9 -23.7 14.9 -50.1 25.9 -28.1 25.9 -34.7
<br />20 13.6 -23.0 13.6 -45.4 24.7 -26.9 24.7 -32.4
<br />50 11.9 -22.2 11.9 -39.3 23.2 -25.4 23.2 -29.3
<br />100 10.5 -21.5 10.5 -34.7 22.0 -24.2 22.0 -26.9
<br />125 10,5 -21.5 10.5 -34.7 21.7 -23.6 21.7 -26.2
<br />NOTES: 1 FOR EFFECTIVE AREAS OR WIND SPEEDS BETWEEN THOSE GIVEN
<br /> ABOVE THE LOAD MAY BE INTERPOLATED, OTHERWISE USE THE
<br /> LOAD ASSOCIATED WITH THE LOWER EFFECTIVE AREA
<br />2 TABLE VALUES SHALL BE ADJUSTED FOR HEIGHT AND EXPOSURE
<br /> BY MUL T1PL YING BY ADJUSTMENT COEFFICIENTS IN TABLE 1606.2D
<br /> OF THE FLORIDA BUILDING CODE 2001.
<br />3 PLUS AND MINUS SIGNS SIGNIFY PRESSURES ACTING TOWARD
<br /> AND AWAY FROM THE BUILDING SURFACES.
<br />
<br />FILLED CELL WI
<br />#5 VERTICAL
<br />
<br />1/2" X 8" A.B.
<br />W/2" WASHERS
<br />SET IN TYP.
<br />FILLED CELL
<br />MIN. 5 PER
<br />JAMB,
<br />
<br />~
<br />
<br />
<br />o
<br />~
<br />..-i
<br />
<br />L SECTIONAL
<br />OVERHEAD
<br />DOOR
<br />
<br />(5) 1/2" DIA. x 8"
<br />"j" BOLTS
<br />
<br />
<br />o
<br />..-i
<br />- '
<br />..-i
<br />
<br />7
<br />
<br />P.T. #
<br />SYP 2" X 6"
<br />
<br />OVERHEAD
<br />SECTIONAL
<br />DOOR TRACK
<br />WI 3/8" X 11/2"
<br />STEEL LAG
<br />BOLT WI
<br />WASHEI1. MIN,
<br />6 PER TRACK
<br />TO JAMB.
<br />
<br /> .
<br /> :1
<br /> ..-i
<br /> GARAGE SLAB
<br /> :1
<br /> ..-i
<br />@
<br />~ 00
<br />
<br />2"x6" P.T. WOOD JA~B
<br />
<br />DOOR AND CONNECTION PER
<br />GARAGE DOOR MANUFACTURER
<br />TYP. GARAGE DOOR
<br />
<br />TRACK MOUNTING DETAIL
<br />
<br />SECT. OVERHEAD GAR. DOOR INSTALL
<br />
<br />SCALE: N.T.S. NOTE: THIS DETAIL HAS A CAPACITY THAT IS EQUAL TO OR
<br />3-15-04 TH GREATER THAN THAT RECOMMENDED BY MANUFACTURER.
<br />
<br />
<br />-EQUIRED SAFETY GLAZING IN HAZARDOUS LOCATIONS
<br />(RE: FBC 2405,1 & 2405.2.1)
<br />
<br />2405.1 General. Individual glazed areas including glass mirrors in
<br />hazardous locations such as those indicated in 2405.2 shall
<br />pass the test requirements of CPSC 16-CFR, Part 1201 or
<br />by comparative test shall be proven to produce at least
<br />equivalent performances.
<br />
<br />Exceptions:
<br />1. Polished wire glass installed in fire doors, fire windows and
<br />view panels in fire resistant walls and hazardous locations in
<br />2405,2.1(3) and 2405,2.1 (4) shall comply with ANSI Z97.1.
<br />2. Approved plastic materials used as glazing in hazardous
<br />locations shall comply with ANSI Z97.1.
<br />
<br />2405,2 Hazardous Locations
<br />2405,2.1 The following shall be considered specific hazardous locations for the purpose
<br />of glazing:
<br />1. Glazing in swinging doors and fixed and sliding panels of sliding (patio)
<br />door assemblies.
<br />2 Glazing in doors and walls of enclosures for hot tubs, whirlpools, saunas, steam
<br />rooms, bathtubs, showers, and other such facilities where such glazing is located
<br />36 inches (914 mm) or less, measured horizontally, from a standing or walking
<br />surface within the enclosure and where the bottom edge of the exposed glazing is
<br />less than 60 inches (1524 mm), measured vertically, above such standing or walking surface,
<br />
<br />3. Glazing in an individual fixed or operable panel adjacent to a door where the
<br />nearest vertical edge is within a 24-inch (610 mm) radius of the door in a
<br />closed position and whose bottom edge is less than 60 inches (1524 mm)
<br />above the floor or walking surface.
<br />
<br />EXCEPTION: Glazing in walls perpendicular to the plane of the door in a closed position in
<br />Group R3 or within dwelling units in Group R2 shall be subject to 2405,2,1 (4).
<br />
<br />4. Glazing in an individual fixed or operable panel, other than those locations
<br />descried in items 2 and 3 above, that meets all of the following conditions:
<br />1. Exposed area of an individual pane greater than 9 sq. ft (0.84 m sq.).
<br />2. Bottom edge less than 18 inches (457 mm) above the floor.
<br />3. Top edge greater than 36 inches (914 mm) above the floor.
<br />4. One or more walking surfaces within 36 inches (914 mm)
<br />horizontally of the plane of the glazing.
<br />
<br />5. All glazing in railings regardless of area or height above a walking
<br />surface including structural baluster panels and non structural in-fill
<br />panels,
<br />6. Glazing in walls and fences enclosing indoor and outdoor swimming
<br />pools and spas where the bottom edge of the glazing is 1) less than 60 inches
<br />(1525 mm) above the walking surface on the pool side of the glazing, and 2)
<br />the glazing is within 60 inches (1525 mm) horizontally of the water's edge of
<br />a swimming pool or spa, This shall apply to single glazing and all panes in
<br />multiple glazing.
<br />
<br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THE
<br />STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH THE
<br />FLORIDA BUILDING CODE, SECTION 1606 FOR 120 M.P.H. 3 SECOND
<br />GUST, EXPOSURE "B" WIND ZONE (2001 EDITION).
<br />
<br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE
<br />DATE IS SIGNED AND SEALED.
<br />
<br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION OF THIS
<br />DRAWING ONLY.
<br />
<br />-
<br />(I)
<br />Z
<br />00:::
<br />oUJ
<br />(j)W
<br />ZZ
<br />~(I)
<br />Oz
<br />u..J
<br />
<br />
<br />
<br />o
<br />~
<br />z
<br />o
<br />(j)
<br />0:::
<br />UJ
<br />>
<br />
<br />(Y)
<br />o
<br />o
<br />":l (J)
<br />c;j Z
<br />~ 0
<br />~ (j)
<br />~ >
<br />o UJ
<br />w 0:::
<br />::J
<br />(/)
<br />(j')
<br />
<br />W
<br />"- ~ D:
<br />UJ w" 0 e: 12
<br />,,~~~~
<br />.......,~-o:J
<br />I- x~a::o
<br />o~g~ts
<br />Z Q.. ~ UJ <l::
<br />:a: 0 ~ f-
<br />w a:: f- 0
<br />W a:: "- w z
<br />1"- <l:: ~ a:: 0
<br />........ 0 w <l:: 0
<br />~1- ~~(/)~
<br />o f-' Z <l::
<br />~ w Q
<br />o 0' ~ ~ ~
<br />o en en W S
<br />U. t5z~tt
<br />UJ ~Qoo
<br />^,g~i5~
<br />u.. iI.Wczu
<br />~ w~wg
<br />::)~a~iIl
<br /><Y5~0g
<br />(j) (/) a:: ~ .......
<br />::J ~ ~ ~
<br /><l:: 0 ;> <l::
<br />
<br />Cf)
<br />-I
<br />.....J
<br />
<br />-
<br />
<br />:c
<br />
<br />>-~
<br />0::-
<br />0>
<br />1-1-
<br />ZCf)
<br />wW
<br />>0::
<br />zO
<br />-0
<br />"0
<br />'8;~
<br />OU
<br />00
<br />1-1
<br />NCO
<br />LO
<br />I~
<br />~O)
<br />~~
<br />LOO
<br />~-I
<br />
<br />()
<br />...J
<br />...J
<br />
<br />l!)
<br />o
<br />o
<br />('\J 00 ,,-"': ";I
<br />"-m oU'
<br />Lf) <.0 ~ 0
<br />~"" i=ow
<br />,., v' a:: a:: t:
<br />,11) wQ..~
<br />........ Q.. (/) I
<br />oeD ~I~
<br />o::~ Q..~Q..
<br />O..-i ~o ~
<br />li~ Q~~
<br />w ~ :J
<br />I ~ I...J 0
<br />()u..: ~~~
<br />~ a:::t: D:
<br />CO <l::f-O
<br />ena I
<br />9 ~~ ~~ ~
<br />-.J..-i""c;;Uz
<br />OOLnw::J~
<br />e.. Lf)N 0 . a::
<br />...... '<j" a~ 0
<br />'c.o<(ZZz
<br />o~()<l::CZo
<br />O(Y) enl;:li=
<br />'<j"..-i S-' Z 0
<br />(Y)oo ~-:J
<br />~ 3:~a
<br />X, <l:: i5 ~
<br />gw ~0Q..
<br />.6 wg 1i!
<br />o en z >-
<br />. I w<l:: ~
<br />0..0.. ~a<l::
<br />10
<br />
<br />~
<br />(l)
<br />.0
<br />C
<br />~ C ..c
<br />.... 0 c
<br />~ (/) >-
<br />C ::1
<br />c:( S I
<br />(l) 1 I
<br />::1
<br />E .S ~
<br />~ ~ ~
<br />
<br />t8100
<br />
<br />3-::""'~-.1
<br />
<br />o
<br />-.;t
<br />..-
<br />..-
<br />,
<br />en
<br />o
<br />(,01'-
<br />('0')1'-
<br />('O')N
<br />-.JI.()
<br />LL.~
<br />-(,0
<br /><(I'-
<br />0..'
<br />~~
<br />~~
<br />
<br />Z
<br />O.
<br />-0
<br />~>
<br />>...J
<br />-(JJ
<br />Ow
<br /><(~
<br />90
<br />~:r:
<br />O(j')
<br />-.Jf-
<br />LL.(j')
<br />...Jwo
<br />C2=s:f5
<br />f-zw
<br />Zoc
<br />Wo::J
<br />()(,O(j')
<br />
<br /> 0:;:0.:
<br /> wet::
<br />LLJ zO
<br />ZU
<br /> <l:W
<br />() ~ ~
<br />>-0
<br /> z :r::
<br />I- <(~
<br />0 ~~
<br />00
<br />W 0:::
<br />Z U LL
<br />::J I-
<br /> oz
<br />I- o W
<br />O:::(/)
<br />CLZZ
<br />::c woo
<br />et::u-
<br />~ wz~
<br />coW~
<br /> 1-1=0
<br />0::: ~C2<1:
<br />>-3Q
<br />>- <(wg5
<br />~:r::-l
<br />a.. Zl-LL
<br />:51--l
<br />0 CL6~
<br />(/):r::~
<br /> -I-
<br />() :r::-W
<br />1-3u
<br />
<br />a..
<br />0:::
<br />o
<br />()
<br />w
<br />~
<br />o
<br />I
<br />(/)
<br />::J
<br />Ii)
<br />o
<br />o
<br />('\J
<br />
<br />@)
<br />
<br />NOTE: iT is THE CONTRACTORS RESPONSIBILITY' TO REVIEW ALL
<br />DRAWINGS BEFORE CO"lSTRUCTlON BEGINS. DANSCO
<br />ENGINEERING, LLC IS RESPONSIBLE FOR THE STRUCTURAL
<br />INTEGRITY' OF THIS PROJECT ONLY. ANY DISCREPANCY BEN/EEN
<br />FIELD CONDITIONS, OTl1ER DESIGN PROFESSIONALS' SHOP DRAWINGS,
<br />CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED
<br />DRAWIr-,GS MUST BE BROUGHT TO THE ATTENTION OF DANSCO
<br />ENGINEERING, LLC PRIOR TO THE COMMENCEMENT OF CONSTRUCTION,
<br />
<br />ll) CO (\j
<br />'<t ll) N
<br />N r-- ~
<br />~ Q') 0
<br />M '<t (D
<br />t.J t.J LlJ
<br />a.: n.. n..
<br />
<br />
<br />tf'i
<br />r:~!
<br />
<br />I............'..
<br />t,'--',::.!
<br />P':';;" I
<br />I' .., I
<br />I
<br />ii:~,:,~:j
<br />t\"
<br />:;;t,.+[
<br />
<br />:t,~1
<br />! !
<br />"-~",
<br />r..........."... '.
<br />.. '.~ ::": !'
<br />t",;"i
<br />I>!
<br />l~'
<br />l~i
<br />l!l
<br />l~'
<br />I u i
<br />II
<br />i~1
<br />UI
<br />r~1
<br />.~t.u
<br />'.. .........':......1....
<br />t.'!
<br />f~',/i
<br />~.,
<br />l.'i;i
<br />,......,.1
<br />f'~1
<br />1.<;'1:
<br />
<br />w
<br />~
<br />~
<br />Z
<br />Z
<br />~
<br />..J
<br />0...
<br />
<br />(Y)
<br />o
<br />o
<br />N
<br />o
<br />0::
<br />o
<br />lL.
<br />><
<br />o
<br />
<br />PLACE SEAL HERE DE #250990
<br />
<br />U)
<br />...J
<br />~
<br />W
<br />o
<br />rY:
<br />o
<br />o
<br />o
<br />cd
<br />S
<br />o
<br />o
<br />z
<br />S LAST PLOT
<br />DATE:ApriI15, 2005
<br />
<br />SHEET NO.
<br />
<br />8-8
<br />
<br />
<br />/
<br />/
<br />/
<br />/
<br />/
<br />I
<br />I
<br />I
<br />f
<br />f
<br />,
<br />,
<br />I
<br />\
<br />\
<br />\
<br />\
<br />\
<br />\
<br />,
<br />,
<br />,
<br />,
<br />,
<br />
<br />,
<br />,
<br />\
<br />,
<br />\
<br />\
<br />\
<br />\
<br />\
<br />I
<br />\
<br />I
<br />,
<br />
<br />APR 1 8 2005
<br />
<br />/
<br />/
<br />I
<br />I
<br />I
<br />/
<br />/
<br />,//
<br />
<br />'....----..-....
<br />
|