<br />AFE LOAD TABLES
<br />
<br />FOR GRAVITY, UPLIFT & LATERAL LOADS
<br />SAFE GRAVITY LOADS FOR 8" PRECAST & PRESTRESSED U-L1NTELS
<br />
<br /> <S~~@OO SAFE LOAD - POUNDS PER LINEAR FOOT
<br /> 8F8-D B 8F12-OB 8F16-0B 8F20-OB 8F24-0B 8F28-DB 8F32-0B
<br />LENGTH * 8U8 8F8-1B 8F12-1B 8F16-1B 8F20-1B 8F24-1B 8F28-1B 8F32-1B
<br /> 3069 4605 6113 7547 8974 10394 11809
<br />2'-10" (34') PRECAST 2231 3069
<br /> 4605 6113 7547 8974 10394 11809
<br /> 3069 3719 5163 6607 8054 9502 10951
<br />3'-6" (42") PRECAST 2231 3069 4605 6113
<br /> 7547 8974 10394 11809
<br /> 2561 2751 3820 4890 5961 7034 8107
<br />4'-0' (48") PRECAST 1966
<br /> 2693 4605 6113 7547 8974 10394 11809
<br />4'-6" (54') PRECAST 1969 2110 2931 3753 4576 5400 6224
<br />1599
<br /> 2189 4375 6113 7547 (7) 8672 10294 11809
<br /> 1349 1438 1999 2560 3123 3686 4249
<br />5'4' (64") PRECAST 1217
<br /> 1663 3090 5365 7547 (36) 7342 (19) 8733 (19) 10127 (19)
<br /> 1105 1173 1631 2090 2549 3009 3470
<br />5'-10" (70") PRECAST 1062
<br /> 1451 2622 4360 7168 (45) 6036 (19) 7181 (19) 8328 (20)
<br /> 1238 2177 3480 3031 3707 4383 5061
<br />6'-6' (78") PRECAST 908
<br /> 1238 2177 3480 5381 8360 1039'\37) 8825 (14)
<br /> 1011 1729 2632 2205 2698 3191 3685
<br />7'-6" (90") PRECAST 743 1011 1729 2661 3898
<br /> 5681 8467 (44) 6472 (15)
<br /> 699 1160 1625 2564 3486 2818 3302
<br />9'-4" (112") PRECAST 554
<br /> 752 1245 1843 2564 3486 4705 (37) 6390 (47)
<br /> 535 890 1247 2093 2777 2163 2536
<br />10'-6" (126") PRECAST 475
<br /> 643 1052 1533 2093 2781 3643 (38) 4754 (45)
<br /> 582 945 1366 1846 2423 3127 4006
<br />11'4" (136') PRECAST 362
<br /> 582 945 1366 1846 2423 3127 4006
<br /> 540 873 1254 1684 2193 2805 3552
<br />12'-0" (144") PRECAST 337 540 873 1254 1684 2193 2805 3552
<br /> 471 755 1075 1428 1838 2316 2883
<br />13'-4" (160") PRECAST 296 1075 1428 2316 2883
<br /> 471 755 1838
<br /> 424 706 1002 1326 1697 2127 2630
<br />14'.0" (168") PRECAST 279 442 706 1002 1326 1697 2127 2630
<br /> NR NR NR I\R NR NR NR
<br />14'.8" (176") PRESTRESSED N.R.
<br /> 458 783 1370 1902 2245 2517 2712
<br /> PRESTRESSED t\R NR NR NR NR NR NR
<br />15'-4" (184") N.R. 412 710 1250 1733 2058 2320 2513
<br /> r--.R NR NR I'<R NR NR r--.R
<br />17'-4" (208") PRESTRESSED N.R.
<br /> 300 548 950 1326 1609 1849 2047
<br /> NR NR NR NR NR NR NR
<br />19'-4" l232') PRESTRESSED N.R.
<br /> 235 420 750 1037 1282 1515 1716
<br />21'4" (256') PRESTRESSED NR NR NR f\R NR NR I'<R
<br /> N.R. 180 340 598 845 1114 1359 1468
<br />22'-0' (264") PRESTRESSED NR NR NR NR NR NR NR
<br /> N.R. 165 315 550 784 1047 1285 1399
<br /> r--.R NR NR r--.R NR NR NR
<br />24'-0" (288") PRESTRESSED N.R.
<br /> 129 250 450 654 884 1092 1222
<br />
<br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR
<br />GR40 FIELD ADDED REBAR. SEE SAFE LOAD TABLE NOTES NO. 12
<br />
<br />(*) LENGTH = OVER ALL LENGTH OF LINTEL
<br />
<br />SAFE LATERAL LOADS FOR
<br />8" PRECAST & PRESTRESSED U-L1NTELS
<br />
<br /> <S~~ SAFE LOAD
<br /> PLF
<br />~ REINF.
<br />LENGTH * 8U8 8F8 CMU**
<br />2'.10" (34') PRECAST 1293 1642 2135
<br />3'.6" (42") PRECAST 1025 1024 1830
<br />4'-0" (48") PRECAST 765 763 1365
<br />4'-6" (54') PRECAST 592 591 1057
<br />5'.4" (64") PRECAST 411 411 734
<br />5'-10" (70") PRECAST 340 339 607
<br />6'-6" (78") PRECAST 507 721 483
<br />7'.6" (90') PRECAST 424 534 357
<br />9'-4" (112") PRECAST 326 512 227
<br />10'-13" (126") PRECAST 284 401 178
<br />11'-4" (136') PRECAST 260 452 152
<br />12'-0" (144") PRECAST 244 402 135
<br />13'-4" (160") PRECAST 217 324 109
<br />14'-0" (168") PRECAST 205 293 98
<br />14'-8" (176") PRESTRESSED N.R. 284 89
<br />15'-4' (184") PRESTRESSED N.R. 259 82
<br />17'-4" (208") PRESTRESSED N.R. 194 63
<br />19'4" (232') PRESTRESSED N.R. 148 51
<br />21'-4" (256') PRESTRESSED N.R, 125 42
<br />22'-0" (264") PRESTRESSED N.R. 116 39
<br />24'-0" (288") PRESTRESSED N.R. 91 33
<br />
<br />(**) SEE SAFE LOAD TABLE NOTES 5
<br />
<br />(*) LENGTH = OVER ALL LENGTH OF LINTEL
<br />
<br />SAFE UPLIFT LOADS FOR 8" PRECAST & PRESTRESSED U-LlNTELS
<br />
<br />@
<br />
<br />@
<br />
<br />@
<br />
<br /> <S~~~ SAFE LOAD - POUNDS PER LINEAR FOOT
<br />~ 8F12-lT 8F16-lT 8F20-lT 8F24-1 T 8F28-lT 8F32-lT
<br />LENGTH * 8F8-2T 8F12.2T 8F16-2T 8F20-2T 8F24-2T 8F28-2T 8F32-2T
<br /> 1972 3173 4460 5747 7034 8321 9608
<br />2'-10" (34") PRECAST 1972 3173 4460
<br /> 5747 7034 8321 9608
<br /> 1569 2524 3547 4569 5591 6613 7636
<br />3'-6" (42") PRECAST 1569 2524 3547
<br /> 4569 5591 6613 7636
<br /> 1363 2192 3079 3966 4853 5740 6627
<br />4'-0" (48") PRECAST
<br /> 1363 2192 3079 3966 4853 5740 6627
<br />4'.6" PRECAST 1207 1940 2724 3508 4292 5077 5861
<br />(54")
<br /> 1207 1940 2724 3508 4292 5077 5861
<br /> 1016 1632 2290 2949 3607 4265 4924
<br />5'-4" (64") PRECAST
<br /> 1016 1632 2290 2949 3607 4265 4924
<br /> 909 1492 2093 2694 3295 3897 4498
<br />5'-10" (70") PRECAST
<br /> 929 1492 2093 2694 3295 3897 4498
<br />6'-6" PRECAST 835 (12) 1340 1880 2419 2959 3498 4038
<br />(78")
<br /> 835 1340 1880 2419 2959 3498 4038
<br /> 727 (23) 1021 1634 (12) 2102 (11) 2571 (10) 3039 (10) 3508 (9)
<br />7'.6" (90") PRECAST
<br /> 727 1166 1634 2102 2571 3039 3508
<br />9'.4" 591 680 1133 (15) 1471 (151 1811(15) 2152 (16) 2494 (15)
<br />(112") PRECAST
<br /> 591 851 1326 1705 2084 2463 2842
<br /> 530 552 914 (15) 1185 (15) 1458 (15) 1732 (15) 2007 (15)
<br />10'6" (126") PRECAST
<br /> 530 686 1183 1526 1865 2204 2544
<br /> 474 485 798 (15) 1034 (15) 1272 (15) 1510 (15) 1749 (15)
<br />11'-4" (136') PRECAST
<br /> 494 599 1028 1422 1738 2053 2369
<br /> 470 (9) 441 723 (14) 936 (14) 1151(15) 1366 (15) 1582 (15)
<br />12'-0" (144") PRECAST
<br /> 470 543 928 1349 1649 1948 2247
<br /> 418 (15) 373 606 (14) 783 (14) 962 (14) 1141(14) 1321 (14)
<br />13'-4" (160") PRECAST
<br /> 428 455 770 1145 1444 1718 1993
<br /> 384 (15) 346 559 (14) 723 (14) 887 (14) 1052 (14) 1218 (14)
<br />14'.0" (168") PRECAST
<br /> 410 420 709 1050 1434 (8) 1694 (8) 1954 (7)
<br /> 239 323 519 (13) 671 (13) 823 (13) 976 (14) 1129 (14)
<br />14'.8" (176") PRESTRESSED
<br /> 246 390 655 968 1324 (8) 1625 (11) 1874 (11)
<br /> PRESTRESSED 224 302 485 (13) 626 (13) 767 (13) 909 (13) 1052 (13)
<br />15'.4" (184")
<br /> 230 364 609 897 1224 (8) 1562 (14) 1801 (14)
<br /> 187 255 404 (12) 520 (12) 637 (12) 754 (12) 872 (12)
<br />17'4" (208") PRESTRESSED
<br /> 192 303 500 732 993 (8) 1268 (14) 1470 (14)
<br />19'-4" (232') PRESTRESSED 162 222 347 (11) 446 (11) 546 (12) 646 (12) 746 (12)
<br /> 166 261 424 616 831 (8) 1057 (14) 1225 (14)
<br />21'-4" (256") PRESTRESSED 142 198 306 (11) 393 (11) 480 (11) 567 (11) 654 (11)
<br /> 142 230 369 531 713 (7) 903 (13) 1046 (13)
<br />22'.0" (264") PRESTRESSED 137 192 295 (10) 378 (11) 461 (10) 545 (11) 629 (11)
<br /> 137 221 354 508 681 (7) 861 (13) 997 (13)
<br /> 124 175 267 (10) 341 (10) 416 (10) 491 (10) 566 (10)
<br />24'.0" (288") PRESTRESSED
<br /> 124 200 316 450 600 (7) 756 (12) 875 (13)
<br />
<br />
<br />
<br />
<br />o
<br />
<br />
<br />
<br />
<br />o
<br />
<br />o
<br />
<br />
<br />o
<br />
<br />@
<br />
<br />@ ELEV. (I) (B.O.L. @ 7'-4" A.F.F.)
<br />(T,OB, @11;-0:A.F.F, ELEV.II) @
<br />(TO,B, @ 10-8 A.F.F., ELEV.lli)
<br />(T.O.B, @ 12'-4' A.F,F, ELEV, IV)
<br />
<br />@
<br />
<br />@
<br />
<br />(#) THE NUMBERS IN PARENTHESIS ARE PERCE~T REDUCTIONS
<br />FOR GR40 FIELD ADDED REBAR. SEE SAFE LOAD TABLE NOTES NO. 12
<br />
<br />(*) LENGTH = OVER ALL LENGTH OF LINTEL
<br />
<br />SAFE GRAVITY LOADS FOR B" PRECAST w/ 2" RECESS DOOR U-L1NTELS
<br />
<br />SAFE UPLIFT LOADS FOR 8" PRECAST wi 2" RECESS DOOR U-L1NTELS
<br />
<br /> <S~~ SAFE LOAD - POUNDS PER LINEAR FOOT
<br />~ 8RF6-OB 8RF10-0B 8RF14-0B 8RF18-0B 8RF22-0B 8RF26.0B 8RF30-0B
<br />LENGTH * 8RU6 8RF6-1B 8RF10-1B 8RF14-1B 8RF18-1B 8RF22-1B 8RF26-1B BRF30-1B
<br /> 1749 3355 3280 4349 5421 6493 7567
<br />4'.4" (52") PRECAST 1635 1891 3699 5206 6639 8060 9479 10893
<br /> 1596 3063 2992 3968 4946 5924 6904
<br />4'.6" (54") PRECAST 1494 1756 3699 5206 6639 8060 9479 10893
<br /> 920 1770 1716 2277 2839 3402 3966
<br />5'-8" (68") PRECAST 866
<br /> 1167 2481 4567 6389 8060 (34) 7917 (19) 9311 (19)
<br /> 859 1653 1600 2124 2649 3174 3700
<br />5'-10" (70") PRECAST 810
<br /> 1113 2342 4242 6639 (10) 8060 (39) 7402 (19) 8706 (19)
<br /> 901 1825 3120 5048 7747 9448 7360
<br />6'-8" (80") PRECAST 797 901 1825 3120 5048 9479
<br /> 7915 10893 (32)
<br /> 755 1490 2459 3776 5743 7239 5623
<br />7'-6" (90') PRECAST 669
<br /> 755 1490 2459 3776 5743 8998 (19) 10893 (48)
<br /> 466 999 1568 2253 3129 4091 3146
<br />9'-8" (116") PRECAST 411
<br /> 526 999 1568 2253 3129 4150 5891 (47)
<br />
<br />(#) THE NUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR
<br />GR40 FIELD ADDED REBAR. SEE SAfE LOAD TABLE I\OTE8 NO. 12
<br />
<br />(*) LENGTH = OVER ALL LENGTH OF LINTEL
<br />
<br />SAFE LATERAL LOADS FOR
<br />8" PRECAST wi 2" RECESS DOOR U.W-HELS
<br />
<br /> <S~~ SAFE LOAD
<br /> PLF
<br />~ 8RF6 REINF.
<br />LENGTH * 8RU6 CMU**
<br />4'-4" (52") PRECAST 758 757 1365
<br />4'.6" (54") PRECAST 694 693 1249
<br />5'-8" (68") PRECAST 408 407 734
<br />5'-10" (70") PRECAST 382 381 687
<br />6'.8" (80") PRECAST 595 788 510
<br />7'-6" (90") PRECAST 509 674 393
<br />9'-8" (116") PRECAST 370 490 227
<br />
<br />(**) SEE SAFE LOAD TABLE NOTES 5
<br />
<br />(*) LENGTH = OVER ALL LENGTH OF LINTEL
<br />
<br /> <S~~~ SAFE LOAD - POUNDS PER LINEAR FOOT
<br />~ 8RF6-lT 8RF10-lT 8RF14-1 T 8RFl8-lT 8RF22-lT 8RF26-1 T 8RF30-lT
<br />LENGTH * 8RF6-2T 8RF10-2T 8RFl4-2T 8RFl8-2T 8RF22-2T BRF26-2T 8RF30-2T
<br /> 905 1748 2635 3522 4409 5296 6183
<br />4'4" (52") PRECAST 905
<br /> 1748 2635 3522 4409 5296 6183
<br /> 867 1675 2525 3374 4224 5074 5924
<br />4'.6" (54") PRECAST 867 1675 2525
<br /> 3374 4224 5074 5924
<br /> 675 1301 1960 2618 3277 3935 4594
<br />5'.8" (68") PRECAST
<br /> 675 1301 1960 2618 3277 3935 4594
<br />5'-10" (70") PRECAST 655 1262 1900 2538 3176 3815 4453
<br /> 655 1262 1900 2538 3176 3815 4453
<br /> 570 1012 1651 2204 2758 3312 3865
<br />6'-8" (80") PRECAST 570
<br /> 1097 1651 2204 2758 3312 3865
<br /> 506 797 1462 (8) 1952 (7) 2442 (6) 2931 (6) 3257
<br />7'-6" (90") PRECAST
<br /> 506 967 1462 1952 2442 2931 3421
<br />9'-8" 395 491 931 (12) 1301 (15) 1640 (15) 1980115) 2322 (16)
<br />(116") PRECAST
<br /> 395 589 1135 1514 1893 2272 2652
<br />
<br />#5 REBAR AT TOP
<br />MIN. (1) REQ'D
<br />1-1/2" CLEAR
<br />
<br />C.M,U,
<br />GROUT
<br />#5 REBAR AT BOTTOM
<br />OF LINTEL CAVITY
<br />
<br />~...
<br />. .,
<br />
<br />
<br />o 0
<br />
<br />
<br />
<br />-.J
<br />et: -.J
<br />~ et:
<br />o Z l-
<br />et: ~I
<br />o~
<br />~ Zw
<br />If) : I
<br />m <.0
<br />...-l ...-l
<br />
<br />LINTEL SCHEDULE
<br />
<br />~'-Q.'-
<br />
<br />.::-0.:.....
<br />
<br />-'
<br />
<br />(#) THE ,\lUMBERS IN PARENTHESIS ARE PERCENT REDUCTIONS FOR
<br />GR40 FIELD ADDED REBAR. SEE SAfE LOAD TABLE NOTES NO. 12
<br />
<br />(*) LENGTH = OVER ALL LENGTH OF LINTEL
<br />
<br />t 7-5/8" J BOTTOM REINFORCING
<br />ACTUAL PROVIDED IN LINTEL
<br />8" NOMINAL WIDTH (VARIES)
<br />TYPE DESIGNATION
<br />IF = FILLED WITH GROUT / U = UNFILLED
<br />r QUANTITY OF #5 REBAR AT
<br />I BOTTOM OF LINTEL CAVITY
<br />8F16-1 B/1T
<br />
<br />NOMINAL WIDTH J J LQUANTITY OF #5
<br />NOMINAL HEIGHT REBAR AT TOP
<br />
<br />@
<br />
<br />/.... ,'.
<br />
<br />,'" -,
<br />
<br />
<br />8F8-1B/OT
<br />
<br />@
<br />
<br />8F16-0B/H
<br />
<br />8F16-1 Bin
<br />
<br />CD
<br />
<br />I MATERIALS
<br />
<br />. f'c 8" precast lintels = 3500 psi
<br />. f'c 8" prestressed, 6" and 12" precast lintels = 6000 psi
<br />. f'c 4" precast lintels = 3000 psi
<br />. Grout per ASTM C476 f'g = 3000 psi w/ maximum
<br />3/8 inch aggregate and 8 to 11 inch slump.
<br />
<br />I ENGINEERING I
<br />SPECIFICATIONS
<br />I PRODUCT DESCRIPTION I
<br />High strength precast concrete lintels designed to be unfilled or filled to form a composite reinforced beam using concrete masonry units.
<br />I GENERAL I\OTES
<br />
<br />. Concrete masonry units (CMU) per ASTM C90 with minimum net area
<br />compressive strenght = 1900 psi
<br />Rebar per ASTM A615 Grade 60
<br />. Prestressing strand per ASTM A416 Grade 270 low relaxation
<br />. 7/32 inch wire per ASTM A510
<br />. Mortar per ASTM C270 Type M or S
<br />
<br />NOTE:
<br />THE LINTEL PLAN PROVIDED HEREIN BY DANSCO ENGINEERING, LLC,
<br />IS INTENDED TO BE USED FOR STRUCTURAL INFORMATION ONLY.
<br />UNLESS SPECIFICALLY NOTED OTHERWISE ON THE PLAN OUR CALC-
<br />ULATIONS ASSUME A 16" (NOM.) DEPTH BETWEEN THE TOP OF THE TIE
<br />BEAM AND BOTTOM OF THE LINTEL. THE NUMBER OF COURSES OF
<br />MASONRY PLACED BETWEEN THE LINTEL AND TIE BEAM IS FOR THE
<br />LOCATION OF THE TOP OF OPENING ONLY AND IS BASED ON THE
<br />ELEVATION PLAN. IN THE EVENT OF A DISCREPANCY THE ELEVATION
<br />PLAN SHALL TAKE PRECEDENCE. WE ARE NOT RESPONSIBLE FOR LINTELS
<br />PLACED AT THE INCORRECT HEIGHT.
<br />
<br />1. Provide full mortar head and bed joints.
<br />2. Shore filled lintels as required.
<br />3. Installation of lintel must comply with architectural
<br />and/or structural drawings.
<br />4. U.Lintels are manufactured with 5-1/2 inch long notches at
<br />ends to accomodate vertical cell reinforcing and grouting.
<br />5. All lintels meet or exceed L/360 vertical deflection, except
<br />lintels 17'.4" and longer with a nominal height of 8" meet
<br />or exceed L/180.
<br />6. Bottom field added rebar to be located at the bottom
<br />of lintel cavity.
<br />7.7/32 inch diameter wire stirrups are welded to the bottom
<br />steel for mechanical anchorage.
<br />
<br />8. Cast-in-place concrete may be provided in composite lintel in lieu of
<br />concrete masonry units.
<br />9. Safe load ratings based on rational design analysis per ACI 318 and ACI 530
<br />10, Product Approvals: Miami Dade County, Florida Nos. 03-0605.05
<br />and 03-0605.04
<br />11. The exterior surface of lintels installed in exterior concrete masonry walls
<br />shall have a coating of stucco applied in accordance with ASTM C926
<br />or other approved coating.
<br />12. Lintels loaded simultaneously with vertical (gravity or uplift) and horizontal
<br />(lateral) loads should be checked for the combined loading with the
<br />following equation:
<br />Applied vertical load Applied horizontal load 1 0
<br />+ < .
<br />Safe vertical load Safe horizontal load
<br />
<br />L
<br />
<br />8. For composite lintel heights not shown, use safe load from
<br />next lower height.
<br />9. For lintel lengths not shown, use safe load from
<br />next longest length.
<br />10. All safe loads in units of pounds per linear foot.
<br />11. All safe loads based on simply supported span.
<br />12. The number in the parenthesis indicates the percent reduction
<br />for grade 40 field added rebar.
<br />Example: 7'.6" lintel Type 8F32-1B safe gravity load = 6472 (15)
<br />w/ 15% reduction => 6472 (.85) = 5501 plf
<br />
<br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THE
<br />STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH THE
<br />FLORIDA BUILDING CODE, SECTION 1606 FOR 120 M.P.H. 3 SECOND
<br />GUST, EXPOSURE "B" WIND ZONE (2001 EDITION).
<br />
<br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE
<br />DATE IS SIGNED AND SEALED.
<br />
<br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION OF THIS
<br />DRAWING ONLY.
<br />
<br />o
<br />...J
<br />...J
<br />
<br />~
<br />o
<br />Z
<br />00:::
<br />OW
<br />(j)UJ
<br />ZZ
<br />~0
<br />Oz
<br />W
<br />
<br />
<br />
<br />o
<br />r1
<br />Z
<br />o
<br />(j)
<br />0:::
<br />W
<br />>
<br />
<br />('I')
<br />o
<br />o
<br />('\J (j)
<br />~ Z
<br />('\J
<br />~ 0
<br />~ (j)
<br />!;t >
<br />o W
<br />UJ 0:::
<br />::J
<br />(/)
<br />(/)
<br />
<br />"-
<br />wO
<br />UJ ~ w
<br />() ~ 9
<br />- - ell
<br />~ ~ 5
<br />o a:: 0
<br />Z 8: :2:
<br /><l:: 0
<br />UJ ~ e:
<br />o <l:: z
<br /><( 53 !i!
<br />~ b ~
<br />o 6 ~
<br />o eIl<l::
<br />u... t5 ~
<br /><l:: 0
<br />W b c;;
<br />0::: f2 ~
<br />~ w;;?;
<br />=> a:: 0
<br />:3 ::J
<br />CYSSc2
<br />(j) ....J W
<br />....J >
<br /><l:: 0
<br />
<br />(f)
<br />-.J
<br />-.J
<br />
<br />-
<br />
<br />:c
<br />
<br />>-~
<br />0::-
<br />0>
<br />.-1-
<br />Z(j)
<br />wW
<br />>0::
<br />zO
<br />-0
<br />~O
<br />~~
<br />00
<br />00
<br />I-.J
<br />(\JCO
<br />L!)
<br />I ~Z
<br />I'- ~ :5
<br />~ VIa.
<br />~l-uJ
<br />LO O~
<br />~ -..J ~
<br />
<br />l!)
<br />o
<br />o
<br />...:(\j
<br />~ ~ ci
<br />i= a ~
<br />a:: D: -
<br />~a.. ~
<br />Q..(/) I
<br />0- 0
<br />a:: I a::
<br />Q.. f- Q..
<br />~6 ~
<br />- f- lJJ
<br />Qz ell
<br />.JJ ~ :J
<br />I~ ~d53
<br />5iu.: ww!::::!
<br />w D::t: a::
<br />(JJ <l::f-O
<br />(/)0 :t:
<br />O<.OD)zzf-
<br />..J<.Oo;;t~<l::~
<br />..J..-imc;;uz
<br />OOl!)~::J:J
<br />a.. Lf)('\J 0 .a::
<br />ct'<j" a~o
<br />'<.Oct: ~zz
<br />o~()<l::a:o
<br />o (") ~[tj B
<br />'<j".-1 zZ:J
<br />('I')~ ;:~a
<br />tj, c2i5~
<br />(JJUJ aoQ..
<br />. Z wg ~
<br />00 eIl~>-
<br />. I W<l:: Z
<br />0..0.. ~a<l::
<br />(0
<br />
<br />"'00
<br />f'..m
<br />Lf)<.O
<br />~m
<br />,l!)
<br />ct'<j"
<br />0<.0
<br />Cl:(1)'
<br />O..-i
<br />u:f2.
<br />
<br />If) co N
<br />~ If) N
<br />N I'- ...-l
<br />~ m 0
<br />C'0 ~ <.0
<br />W w W
<br />0.... 0.... 0..:
<br />
<br />~
<br />OJ
<br />..Cl
<br />C
<br />OJ c
<br />OJ 0 ..c
<br />"- rJ) C
<br /><.9 C >.
<br />:::l
<br />~ ~ I
<br />OJ 1 I
<br />:::l
<br />E .S ~
<br />ro ~ ..c
<br />
<br />iJoD
<br />
<br />w
<br />~ a::
<br />c2f2
<br />"-
<br />~ ~
<br />o :J
<br />a:: 0
<br />"-e
<br />~ <l::
<br />~ f-
<br />~ ~
<br />Wo
<br />~ 0
<br />~ ~
<br />c;; w
<br />z :2:
<br />w c2
<br />:2: "-
<br />50
<br />a:: f-
<br />o ~
<br />ffi g
<br />f- ....J
<br />Z en
<br />-. a::
<br />(/)0
<br />....J .......
<br />....J 0
<br /><l:: Z
<br />3: <l::
<br />
<br />
<br />z
<br />O.
<br />-0
<br />~>
<br />>...J
<br />-(JJ
<br />Ow
<br /><t:cz:::
<br />90
<br />CZ:::I
<br />O(/)
<br />-.JI-
<br />LL(/)
<br />-.Jwa
<br />~s:g
<br />I-ZW
<br />Z I-
<br />waS
<br />of5(j)
<br />
<br />f~!
<br />
<br />. "'<,,: ,,!
<br />
<br />r!"j
<br />,---~.. .
<br />;;;~7.:;,-.;_:' !
<br />
<br />~ri
<br />;;t:-f.,
<br />-_._~.. ~~~~,.,::-~:: :
<br />:..':_.,1
<br />:~"'. !--""".;
<br />.. F~ti!
<br />r'~i
<br />~i
<br />Ii'
<br />}" ;
<br />11
<br />,f\.,
<br />i~m!
<br />I . !
<br />~l
<br />
<br />
<br />I t;.: ,
<br />1~~1
<br />J1,
<br />l~j
<br />
<br />i.:~,:i
<br />i~:i
<br />"'N-c ~
<br />,- .'1
<br />I i
<br />~~
<br />{'t'i
<br />t:~;~i
<br />
<br />a
<br />v
<br />.-
<br />.-
<br />,
<br />C')
<br />a
<br />\Of'..
<br />~f'..
<br />~N
<br />...Jl()
<br />LLa',
<br /><{~
<br />0...'
<br />~~
<br />;::~
<br />
<br /> (Y)
<br /> 0 0:::&
<br /> Wo
<br /> 0 LJ..J ~u
<br /> <l:W
<br /> N () ~~
<br /> >-0
<br /> z::C
<br /> 0 I- <t~
<br /> ?;;~
<br /> 0:: 0 00
<br /> wo:::
<br /> Z ULL
<br /> 0 6~
<br /> ow
<br />w LL I- o:::(/)
<br />a.Zz
<br />~ >< I woo
<br />O:::u-
<br /> 0 ~ wz~
<br /><( cow>
<br />I-t::B
<br />Z 0::: ~ii~
<br /> >-39
<br />Z >- <twO:::
<br /> ~::co
<br /><( a.. zl-ri
<br /> :51--l
<br /> ~ <(
<br />...J 0 0..00:::
<br /> (/)::cl-
<br />a. _1-2
<br /> () ::c-w
<br /> 1-3u
<br />SHEET NO, a..
<br /> 0:::
<br /> 0
<br /> S-2A ()
<br /> w
<br /> ~
<br /> 0
<br /> I
<br /> (/)
<br /> ::J
<br /> Lf)
<br /> 0
<br /> 0
<br /> ('\J
<br />LAST PLOT C0
<br />DATE:Aphl 15, 2005
<br />
<br />NOTE: IT IS THE CONTRACTORS RESPONSIBIUlY TO REVIEW ALL
<br />DRAWINGS BEFORE CONSTRJCTlON BEGINS, DANSCO
<br />ENGINEERING, LLC IS RESPO';SIBlE FOR THE STRUCTURAL
<br />INTEGRllY OF THIS PROJECT ONLY. ANY DISCREPANCY BETWEEN
<br />FIELD CONDITIONS, OTHER DESIGN PROFESSIOI\AlS' SHOP DRAWINGS,
<br />CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND SEALED
<br />DRAWII\;GS MUST BE BROUGHT TO THE ATTENTION Of DANSCO
<br />ENGINEERING, LLC PRIOR TO THE COMMENCEMENT OF CONSTRUCTION,
<br />
<br />
<br />,
<br />,
<br />,
<br />,
<br />\
<br />\
<br />\
<br />\
<br />\
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />
<br />I SAFE LOAD TABLE NOTES
<br />
<br />1. All values based on minimum 4 inch nominal bearing.
<br />Exception: Safe loads for unfilled lintels must be reduced
<br />by 20 % if bearing length is less than 6-1/2 inches.
<br />2. N.R. = Not Rated.
<br />3. Safe loads are superimposed allowable load.
<br />4. Safe loads based on Grade 40 or Grade 60 field rebar.
<br />5. Additional lateral load capacity can be obtained by the
<br />designer by providing additional reinforced masonry above
<br />the precast lintel. See Reinforced CMU on Page 4.
<br />6. One #7 rebar may be substituted for two #5 rebars in 8" lintels only.
<br />7. The designer may evalute concentrated loads from the safe load tables
<br />by calculating the maximum resisting moment and shear at d-away
<br />from the face of support.
<br />
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />,
<br />I
<br />I
<br />I
<br />\
<br />\
<br />\ APR 1 8 2005
<br />\
<br />\
<br />,
<br />,
<br />,
<br />
<br />PLACE SEAL HERE DE #250990
<br />
<br />-----_.....'
<br />
|