Laserfiche WebLink
<br />Limitations <br /> <br />1. The Therma- Tru Corporation 3'0 x 6'8 "Smooth Star" Fiberglass Single "Impact", In-swing or Out-swing <br />Do.or has been evaluated and meets the requirements for use within the State of Florida excluding the ''High <br />Velocity Hurricane Zone". <br /> <br />2. This product is not to be used in "Essential Facilities" as defined in ASTM E1996-02 section 6.2.1.1. <br /> <br />3. When used in wind-borne debris regions, this product complies with section 1609.1.4 as an impact resistant <br />product and does not require protection from an impact resistant covering. <br /> <br />4. Size Limitations: <br /> <br />Configurations <br /> <br />MAX. Frame Width <br /> <br />MAX. Frame Height <br /> <br />Single X <br /> <br />37.59" <br /> <br />82.19" <br /> <br />5. The Design Pressure Rating (PSF) for the Single units are as follows: <br /> <br />Swing Overall Design Pressure (PSF) <br />Frame Dimensions Positive Negative <br />In-Swing 37.59" x 82.19" + 67.0 PSF - 67.0 PSF <br />Out-Swing 37.59" x 80.69" + 67.0 PSF - 67.0 PSF <br /> <br />~/~.. <br />Wendell W. "ey, It!J <br />FL No. 54158 <br />November 18, 2005 <br /> <br /> <br />EVAL 5891.2-PF 863 <br /> <br />Sheet 2 of3 <br />