Laserfiche WebLink
<br />FORM 600A-2004 <br /> <br />EnergyGauge@ 4.0 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />, ADDRESS: , , , PERMIT #: <br /> <br />6A-21 INFILTRATION REDUCTION COIIPUANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREIIENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 MIrJcimum:.3 ctnIsq.1l window area; .5 cfmIsq.1l door area. <br />Exterior & A$Cent WaIs 606.1.ABC.1.2.1 Caulk, gasket, lIIIB8ItDab~ oue. belween: windowsfdoof5 & fIwnes. SUITOUnding waI; <br />foundation & waD sole or . pI8Ie; joinIs belween exterior waI panels at comers; uIIIy <br />peI.eb<llliof1S; between waI panels & topIboUom plates; between walls _floor. <br />EXCEPTION: FrMIe walls wheIe a conIhIous ilA..diuiI barrier is lnsIaIed thai exIillnds <br />from. and is S88Ied to, the foundation to the lop plate. <br />FIoor.5 606. 1.ABC. 1.2.2 Penelwaliolls/opellings >118" se8Ied unless b8cked by truss or joint members. <br />EXCEPTION: FrMIe tIoors wheIe a conIinuous iuftllatioo banier is insIaIIed thai is sealed <br />to the perirneIIlr, perWlb.oollS and seams. <br />Ceilings 606.1.ABC.1.2.3 Between walls & ~; peneb.aliollS of ceiling plene of lop floor; around shafts. chases, <br />sallis, cI*nneys. cablneIs sealed 10 continuous air barrier; gaps in gyp board & top pIRIe; <br />attic access. EXCEPTION: FrMIe ~ wheIe 8 conIlnuous infIInIIion banier is <br />instaIed that is se8Ied at the peIirnMBr. at pelleIraliollS and seams. <br />Recessed lighting F"1XIuIes 606.1.ABC.1.2.4 Type IC rated will no pelletratiollS. se8Ied; or Type Ie or non-IC rated. insIaIed inside a <br />sealed box will 112" c:Ieanmce & 3" from insulation; or Type Ie rated will < 2.0 dm from <br />condIIoned space. 18st8d. <br />Multi-stOfy Houses 606.1.ABC.1.2.5 Air banier on peIirnMBr of ftoor cavily between tIoors. . <br />AdditionaII..lIb"""l reqts 606.1.ABC.1.3 Exhaust fans venIed 10 ouIdooIs. danlp8lS: combustion space he8ters comply willi NFPA, <br />have combustion air. <br /> <br />COIIPONENTS SECTION <br />Water Heaters 612.1 <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exeMCled by aU residences.) <br /> <br />Swimming Pools & Spas 612.1 <br /> <br />Showerheads 612.1 <br />Air Distribution Systems 610.1 <br /> <br />HVAC Controls 607.1 <br />Insulation 604.1. 602.1 <br /> <br />REQUIREIIENTS CHECK <br />Comply wiIh efliciellGY requhmenIs in Table 612.1.ABC.3.2. SwIctt or cIearty naked cir <br />breaker (eIedric) or cDoff (gas) must be prcMded. ExIemaI or buiI-iR heat trap teqUinld. <br />Spas & heated pools must have CDlI8fS (except solar heated). Non-conftlel'dal pools <br />must have a pump timer. Gas spa & pool healers must have a minimum thermal <br />efJiciency of 78%. <br />Walei' flow must be I8SIrided to no more than 2.5 gaIons per minute at 80 PSIG. <br />AI duels. filings, mechanical equipment and plenum chambers shall be mechanically <br />alIached, sealed. insulated. and insIaIed in accordance will the aiIeria of Sedion 610. <br />Duels in unconcIIioned allies: R-6 min. insulation. <br />SeparaIie readily ..... Bille manual or aulomaIic IhermosIat for each sysIII!m. <br />Ceilings Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. <br />Common ceiling & ftoors R-11. <br /> <br />EnergyGauge- DCA Form 600A-2004 <br /> <br />~S'2004 FlRCSBY4.0 <br />