Laserfiche WebLink
<br /> <br />. <br /> <br />EIiIB Software ~ Inc. <br />Bachet1412 <br />P 1 <br /> <br />I Rhvac - Residential & Light Commercial HVAC Loads <br />i HYAC DesIgn Service Inc. <br />I Tampa, Fl 33624 <br /> <br />I Total Building Summary Loads <br /> <br />ComponEmt <br />: Descri lion <br />1 A-cI1H>: Glazing-Single pane, operable window, clear, <br />metal frame no break, outdoor insect screen with <br />50% coverage, light color drapes with medium weave <br />with 25% coverage, u-value 1.27 <br />1A-cm-o: Glazing-Single pane, operable window, clear, <br />metal frame no break, u-value 1.27 <br />11 D: Door-Solid Core <br />12B-Osw: WaD-Frame, R-11 insulation in 2 x 4 stud <br />cavity, no board insulation, siding finish, wood studs <br />12B-Osw: Part-Frame, R-11 insulation in 2 x 4 stud cavity, <br />no board insulation, siding finish, wood studs <br />16B-19: Roof/Ceiling-Under attic or knee wall, Vented <br />Attic, No Radiant Banier, Dark Asphalt Shingles or <br />Dark Metal, Tar and Gravel or Membrane. R-19 <br />insulation <br />22A-pm-c: FIoor-S1ab on grade, No edge insulation, no <br />insulation below floor, carpet covering. passive. <br />heavy dry or light wet soil <br /> <br />Subtotals for structure: <br />People: <br />Equipment: <br />Lighting: <br />Ductwork: <br />Infiltration: Wmter CFM: 85, Summer CFM: 43 <br />Ventilation: Wmter CFM: 0, Summer CFM: 0 <br />AED Excursion: <br /> <br />Total Building load Totals: <br /> <br />Area <br />Quan <br />60 <br /> <br />San <br />J..oss <br />2,440 <br /> <br />Lat San <br />Gain Gain <br />o 3,6~ <br /> <br />57 <br /> <br />2,317 <br /> <br />o 4.034 4.034 <br /> <br />42 <br />902 <br /> <br />508 <br />2,801 <br /> <br />o 418 418 <br />o 2,547' 2.547 <br /> <br />331 <br /> <br />962 <br /> <br />o 642 642 <br /> <br />o 3,805 3,805 <br /> <br />1412 <br /> <br />2,214 <br /> <br />174 6,569 0 <br /> 17,811 0 <br />4 920 <br /> 220 <br />0 <br /> 4,510 826 <br /> 2,980 805 <br /> 0 0 <br /> 0 0 <br /> 25,301 2,n1 <br /> <br />I Check FlQures <br />Total Building Supply CFM: 1,200 <br />Squareft. of Room Area: 1,412 <br />I Volume (~ of Cond. Space: 11,296 <br /> <br />II Building Loads <br />Total Heating Required With Outside Air: 25,301 Btuh <br />I Total Sensble Gain: 24,342 Btuh <br />I Total Latent Gain: 2,n1 Btuh <br />I Total Cooling Required With OUtside Air: 27,113 Btuh <br /> <br /> <br />II Notes , " ,,' ., '.' <br />I Calculations are based on 8th edition of ACCA Manual J. <br />I All computed results are estimates as building use and weather may vary. <br />Be sure to select a unit that meets both sensible and latent loads. <br /> <br />I <br /> <br />CFM Per Square ft.: <br />Square ft. Per Ton: <br />Air Turnover Rate (per hour): <br /> <br />25.301 <br />90 <br />10 <br />2.26 <br />2.78 <br /> <br />15,144 <br />1,200 <br />1,500 <br />o <br />5,050 <br />953 <br />o <br />495 <br />24,342 <br /> <br />o <br /> <br />o <br /> <br />15,144 <br />2,120 <br />1.720 <br />o <br />5,876 <br />1,758 <br />o <br />495 <br />27,113 <br /> <br />0.850 <br />508 <br />6.4 <br /> <br />MBH <br />% <br />% <br />Tons (Based On Sensible + Latent) <br />Tons (Based On 73% Sensible Capacity) <br />