<br />! <br />~ . <br /> <br />.ADDITIONAL TABLES <br /> <br />CUMATEZONES 4 5 6 <br /> <br /> <br />6A.20 AIR DISTRIBUTION SYSTEM CREDIT MUL npUERS <br />TYPE CREDIT Prescriptive requirements Multiplier <br />AirtightDud credit 610.1.A.l 1.00 <br />Fado -sealed AHU cred'rt 610.2.A.2.1 0.95 <br />lDuct Sealing Multiplier (DSM) shall be 1.15 (summer) or 1.16 (winter) unless Airtighl Duct credit is <br />demonstrated by test report. <br />2Multiply Factory-sealed AHU credit by summer (Table 6A-7) or winter (Table 6A-16) AHU multiplier. <br />Insert total in the "AS-Built AHU" box on page 2 or 4. <br /> <br />6A-21 HEA nNG CREDIT MUL TlPUERS (HCM) <br /> <br />In; HEA TIN <br />Proarammable Thermostat HCM .95 <br />Multizone HCM .----- -------- .95 <br />Natural Gas AFUE .68-.72 I .73-.77 I .78-.82 I ,83-.87 I .88-.92 I ,93 & Uo <br />HCM .61 I .56 I .53 I .50 I .47 I .44 <br />LP Gas HCM .77 I .72 I .67 I .63 I .60 I .57 <br /> <br />6A-22 HOT WATER MULTlPUERS IHWMI <br />SYSTEM TYPE See Table 6- 12 for Code minimums HOT WATER MULTlPUERS (HWMI <br />Electric Resistance EF --.._- -- ~---j_--:~2~1 I '~~5~ .84-,85 ,86-.87 88-.90 ,91-.93 .94-.96 .97 & Uo <br />HWM 2685 2624 2564 2479 2400 2326 <br />Natural Gas EF .43-.47 .48- .49 .50-.51 .52-.53 .54-.55 .56-.57 .58-.59 .60-.61 .62-.63 .64-.65 .66 & Uo <br />HWM 2162 1936 1859 1787 1721 1660 1602 1549 1499 1452 1408 <br />LP Gas HWM 2645 2368 2274 2186 2106 2031 1960 1895 1634 1776 1722 <br />Oed, HP or Solar EF 1.0-1.49 1.5-1.99 2,()'2.49 2.5-2.99 3.0-3.49 3.5-3,99 4.0-4.49 45-4.99 5.().Up <br />System with Tank HWM 2256 1504 1128 902 752 645 564 501 451 <br /> <br />6A.23 HOT WATER CREDIT MULTIPLIERS IHWCMI <br /> SYSTEM TYPE HOT WATER CREDIT MULTIPLIERS (HWCMI ._-~ <br />Heat Recovery Unit With Air Conditioner Heat Pumn <br /> HWCM --- .84 .78 <br />Add-on Dedicated Heat Pump EF 2,0-2.49 2.5-2.99 3.0-3.49 I 3.5 & Up <br />(without tank) HWCM ---....-..---- .44 .35 .29 I .25 ___ <br />Add-on Solar Water Heater EF 1.0-1.9 2,0-2.9 3,0-3.9 I 4.0-4.9 I 5.0 & Un <br />(without tank) HWCM .84 .42 .28 I .21 I .17 <br /> <br />NOTE: A HWM must be used in conjunction with all HWCM. See Table 6M2. EF Means Energy Factor <br /> <br />6A-24 INALTRATlON REDUCTION COMPLIANCE CHECKLIST <br /> <br />COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE CHECK <br />Exterior Windows & Doors 606.1.ABC.1.1 Max: .3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. <br />Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br /> foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br /> penetrations; between wall panels & topibottom plates; between walls & floor. <br /> EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br /> from, and is sealed to, the foundation to the top plate. <br />Floors 606,1.ABC.1.2.2 Penetrations/openings> 1/8" sealed unless backed by truss or joint members. <br /> EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br /> to the perimeter, penetrations and seams. <br />Ceilings 606. l.ABC, 1.2,3 Seal: Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br /> soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br /> attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br /> installed that is sealed at the perimeter, at penetrations and seams, <br />Recessed Lighting Fixtures 606.1..A.BC ,1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br /> sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with <2.0 cfm from <br /> conditioned soace tested. <br />Multi-story Houses 606.1.ABC.l.2.5 Air barrier on perimeter of floor cavity between floors. <br />Additional Infiltration reqts 606.1.ABC.1.3 Exhaust fans vented 10 outdoors, dampers; combustion space heaters comply with NFPA, <br /> have combuslion air. <br /> <br />6A-25 OTHER PRESCRIPTIVE MEASURES Imust be met or exceeded bv all residences.l <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) <br /> or cutoff (aas) must be provided. External or built-in heat trap reauired for vertical pipe risers. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar healed). Non-commercial pools must have a pump timer. Gas spa <br /> & pool heaters must have a minimum thermal efficiency of 78%. <br />Shower Heads 612.1 Water flow must be restricted 10 no more Ihan 2.5 callons oar minute at 80 PSIG. <br />Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, <br /> sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 minimum <br /> insulation. <br />HV AC Controls 607.1 Seoarate readilv accessible manual or automatic thermostat for each system. <br />Insulation 604.1,602.1 Ceilinas-Min. R-19. Common walls-Frame R-11 orCSS R-3 both sides. Common ceiling & floors R-l1. <br /> <br />Effective date: March 1, 2003 <br />