My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-6951
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-6951
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:49:04 PM
Creation date
5/6/2008 9:47:05 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-6951
Building Department - Name
PEEPLES FAMILY CORP.
Address
5217 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />@> Flre.L1Te" ALarms <br /> <br />www.firelite.com <br /> <br />July 14, 2004 <br /> <br />DF-52004 F-050 <br /> <br />BG-12 Series <br />Manual Fire Alarm Pull Stations <br /> <br />Section: Conventional Initiating Devices <br /> <br />GENERAL <br /> <br />The FireoLite Alarms BG-12 Series is a cost-effective, fea- <br />ture-packed, non-coded series of manual fire alarm pull <br />stations. It was designed to meet multiple applications <br />with the installer and end-user in mind. The BG-12 Series <br />features a variety of models including single- and dual- <br />action versions. <br />The BG-12 Series provides Fire'Lite Fire Alarm Control <br />Panels (FACPs), as well as other manufacturers' controls, <br />with a manual alarm initiating input signal. Its innovative <br />design, durable construction, and multiple mounting op- <br />tions make the BG-12 Series simple to install, maintain, <br />and operate. <br /> <br />FEATURES <br /> <br />. Aesthetically pleasing, highly visible design/color. <br />. Attractive contoured shape with light textured finish. <br />. Meets ADA 5 lb. maximum pUll-force. <br />. Meets UL 38, Standard for Manually Actuated Signaling <br />Boxes. <br />. Easily operated (single- or dual-action), yet designed to <br />prevent false alarms when bumped, shaken, or jarred. <br />. PUSH IN/PULL DOWN handle latches in the down po- <br />sition to clearly indicate the station has been operated. <br />. The word "ACTIVATED" appea rs on the top of the handle <br />in bright yellow, further indicating operation of the sta- <br />tion. <br />. Operation handle features white arrows showing basic <br />operation direction, for non-English-speaking persons. <br />. Braille text included in finger-hold area of operation <br />handle and across top of handle. <br />. Multiple hex- and key-lock models available. <br />. U.S. patent-pending hex-lock needs only a quarter-turn <br />to lock/unlock. <br />. Station can be opened for inspection and maintenance <br />without initiating an alarm. <br />. Product ID label viewable by simply opening the cover; <br />label is made of a durable long-life material. <br />. The words "NORMAL" and "ACTIVATED" are molded <br />into the plastic adjacent to the alarm switch (located in- <br />side). <br />. Four-position terminal strip molded into backplate. <br />. Terminal strip includes Phillips combination-head cap- <br />tive 8/32 screws for easy connection to Initiating Device <br />Circuit (IDC). <br />. Terminal screws backed-out at factory and shipped ready <br />to accept field wiring (up to 12 AWG/3.25 mm2). <br /> <br />c@us <br />LISTED <br /> <br />~ <br />APPROVED <br /> <br /> <br />California <br />'~ State Fire <br />Marshal <br />') 7150-0075:184 <br /> <br />MEA <br /> <br />67 -02-E <br /> <br /> <br />. Terminal numbers are molded into the backplate, elimi- <br />nating the need for labels. <br />. Switch contacts are normally open. <br />. Can be surface (with SB-I/O or SB-10) or semi-flush <br />mounted. Semi-flush mount to a standard single-gang, <br />double-gang, or 4" (10.16 cm) square electrical box. <br />. Backplate is large enough to overlap a single-gang <br />backbox cutout by up to 1/2" (12.7 mm). <br />. Optional trim ring (BG-TR). <br />. Spanish version (FUEGO) available (BG-12LSP). <br />. Designed to replace the Fire.Lite Legacy BG-1 0 Series. <br />. Models packaged in attractive, clear plastic (PVC), <br />clamshell-style, Point-of-Purchase packages. Packag- <br />ing includes a cutaway dust/paint cover in shape of pull <br />station. <br /> <br />Fire.Lite@ Alarms is a Honeywell company. <br />This document is not intended to be used for installation purposes. We try to keep <br />our product information up-to-date and accurate. We cannot cover all specific <br />applications or anticipate all requirements. All specifications are subject to <br />change without notice. <br />For more information, contact Fire'Lite Alarms, One Fire-Lite Place, Northford, <br />Connecticut 06472. Phone: (800) 627-3473, Toll-Free FAX: (877) 699-4105. <br /> <br />ISO 9001 <br /> <br />III <br /> <br />CERTIFIED <br /> <br />~I- <br />GIllin SYSTEMS <br /> <br />DF-52004. 07/14/04 - Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.