Laserfiche WebLink
<br />@) Flre.UTe" ALarms <br /> <br />March 30, 2000 <br /> <br />G-250 <br /> <br />SpectrAlert ™ Series <br />Horns, Strobes, and Horn/Strobes <br /> <br />GENERAL <br /> <br />Section: AudioNisual Devices <br /> <br />System Sensor SpectrAlert Series strobes, horns, and combina- <br />tion horn/strobes are UL listed for primary signaling in life safety <br />systems and meet ADA public mode visible signaling requirements. <br /> <br />SpectrAlert products can be connected to the alarm indicating cir- <br />cuit of a fire alarm control panel and are compatible with DC line <br />supervision. The SpectrAlert product line mounts to standard <br />backboxes using a universal mounting plate included with each unit. <br />An optional small footprint mounting plate fits to a single-gang box. <br />An accessory backbox skirt gives a cosmetic finish to a 4" x 4" x <br />1-1/2" or a 2" x 4" x 1-7/8" surface-mounted backbox. All strobe <br />and horn/strobe mounting options require only one screw attach- <br />ment of product to plate. <br /> <br />These products are designed for 12 and 24 VDC and full-wave rec- <br />tified unfiltered power. Full-wave rectified operation requires more <br />current than DC operation. For detailed current draw information, <br />consult the Current Draw Tables (page 2). The horn/strobe com- <br />bination products are factory-assembled with jumper wires for in- <br />tandem operation. For independent wiring of horn and strobe, re- <br />move jumper wires. When wired for independent operation, the <br />strobe will continue to run while the horn can be silenced. How- <br />ever, the strobe must be running for horn to operate. <br /> <br />Horns - The SpectrAlert Series horns and horn/strobes pro- <br />vide two different field-selectable/reversible tones, a high-low field- <br />selectable/reversible sound output setting (low selling on 24-volt <br />models only) and a field-selectable/reversible temp 3 pattern or <br />non-temporal continuous pattern. These field-selectable features <br />are accomplished using pins and jumpers located on the back of <br />each SpectrAlert horn and horn/strobe. An accessory module is <br />not needed to make these field selections. The horn on horn/strobe <br />models will operate on a coded power supply. Those horn-only <br />models with "He" in their part numbers will also operate on a <br />coded power supply. The horn and horn/strobe series includes <br />weatherproof models. <br /> <br />Strobes - The ADA-compliant SpectrAlert strobes are elec- <br />tronic visible warning signals that flash at 1 Hz over their operating <br />voltage range. These products are available in 24-volt models at <br />15, 15/75, 75 and 110 candela intensities and in 12-volt models at <br />15 and 15/75 candela intensities. The strobe series includes weath- <br />erproof models. SpectrAlert products feature dramatic reductions <br />in current requirements. <br /> <br />Sync-Circuit Module (MDL) - The SynceCircuit Mod- <br />ule is available for synchronization of strobes and horns and can <br />synchronize two Style Y (class B) circuits or one Style Z (class A) <br />circuit. The module can also generate a synchronized temp 3 tone <br />for System Sensor's Multi-Alert™ and PA400 horn products.' The <br />synchronization module allows the SpectrAlert horns on combina- <br />tion horn/strobes to be silenced on two-wire systems. SpectrAlert's <br />SynceCircuit Module can be daisy-chained for multiple zone syn- <br />chronization. The module does not operate on a coded power sup- <br />ply. <br />'For Multi-Alert and PA400: Strobes must be wired to a continuous <br />source of power (non-coded power supply). <br /> <br />@L"'S4011&S5512(P1215'P121575'P2415' <br />(ii) P241575, P2475, P24110). 55512 (81215, <br />8121575,82415,8241575,82475,824110). <br />LISTED S4011 (HC12/24). <br /> <br />@C...CS549(P2415A,P241575A,P2475A,P24110A, <br />II 82415A, 8241575A, 82475A, 824110A). <br />C CS548 (H12/24A, HC12/24A). <br /> <br />OB8A4.AY(P1215,P121575, ~ ~ <br />P2415,P241575,P2475,P24110, ~ <br />81215,8121575,82415,8241575, <br />82475,824110, H12/24). OD4A7.AV (HC12/24). <br /> <br /> <br />(~....~). ... <br />In <br />~.G, :'s,.~l i'.. <br />~. <br />Itv~ <br />_..=Jl <br />California <br />State Fire <br />Marshal <br /> <br />7135-1209:173 (P1215, P121575, P2415, <br />P241575, P2475, P24110). <br />7125-1209:174 (81215, 8121575, <br />82415,8241575,82475,824110). <br />7135-1209:143 (H12/24, HC12/24). <br /> <br />MEA ... 319-96-E (P1215, P121575, <br />P2415, P241575. P2475, <br />P24110,81215,8121575, <br />82415,8241575,82475, <br />824110, H12/24, HC12/24). <br /> <br /> <br />Cl <br />.~ <br />c. <br />'" <br />o <br />~ <br />'" <br /> <br />SpectrAlert™, Sync-Circult™, and Multl-Alert™ are trade- <br />marks of System Sensor, a division of Pillway Corporation. <br /> <br />This document is not intended to be used for installation purposes. We try to keep our product <br />information up-ta-date and accurate. We cannot cover all specific applications or anticipate all <br />requirements. All specifications are subject to change without notice. For more information. <br />contact FireoLite Alarms, One Rre-Lite Place, Northford, Connecticut 06472. Phone: (800) 627- <br />3473. Toll Free FAX: (877) 699-4105, FAX Back:(888) 388-3299 <br />WEB: www.firelite.com <br /> <br />ISO 9001 <br /> <br />CERTIFIED <br /> <br />"'_1- <br /> <br />DF-51609 - Page 1 of 6 <br />