My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-7025
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-7025
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:48:58 PM
Creation date
5/6/2008 10:01:32 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-7025
Building Department - Name
LONGSTREET,PATRICK
Address
5943 19TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />: FORM 600A-2004R <br /> <br />EnergyGauge@ 4.5 <br /> <br />Code Compliance Checklist <br />Residential Whole Building Performance Method A - Details <br /> <br />~.DDRESS: , , , <br />6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST <br /> <br />PERMIT #: <br /> <br />COMPONENTS SECTION <br />E~ri~~Vytndo":"~&=DOO~--J 606.1.A~C;:, 1.1 <br />Exterior & Adjacent Walls I 606.1.ABC.1.2.1 <br /> <br />! REQUIREMENTS FOR EACH PRACTICE CHECK <br />-t-. m --- ---~--~~--.- <br />I Maximum:.3 cfm/sq.ft. window area; .5 cfm/sq.ft. door area. ________ _~_ <br />I Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; <br />foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility <br />penetrations; between wall panels & top/bottom plates; between walls and floor. <br />EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends <br />-___~_____n______ _ I from, and is ~~aled to, the foundation to the top plate. ______~_ <br />606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss or joint members. I <br />EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed <br />to the perimeter, penetrations and seams. ~___~_ <br />606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, <br />soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; <br />attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is <br />_____._~_._~__ installed that is sealed at the QE'lrimeter, at penetrations and seams. <br />Recessed Lighting Fixtures ! 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non-IC rated, installed inside a <br />. sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from <br />I <br />-------- ------------t -- ---------+- conditione(L~pace, tested._ _ .__ '________ <br />Multi-story Ijouses _____.~_+606.1.ABC.1.2.5 L~ir barrierc:m perimeter of floor cavity between floors. _.__ <br />Additional Infiltration reqts ! 606.1.ABC.1.3 I Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, <br />have combustion air. <br /> <br />Floors <br /> <br />Ceilings <br /> <br />6A-22 OTHER PRESCRIPTIVE MEASURES (must be met or exceeded by all residences.) <br /> <br />CONlf>ONENTS. _______ ~ · SECTION I REQUIREMENTS__~ CHECK <br />Water Heaters 612.1 Comply with efficiency requirements in Table 612.1.ABC.3.2. Switch or clearly marked cir <br />C-----.. n________________~__------Pr~aker (ele_~tric) or cutoff (gas) must be provided. External or built-in heat trap required. <br />Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools <br />: must have a pump timer. Gas spa & pool heaters must have a minimum thermal <br />_________ -L-----.---- effigi_ency of 78%. _ _ ___~-___ <br />~lIVer head~ ____---.l21~_____Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. __L _____ <br />Air Distribution Systems I 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically <br />I " ., attached, s, ealed, insulated, and installed in accordance with the criteria of Section 610,', <br />_______________-+-__ __l Ducts in uncondition~d attics: R-6 min. insulation. _ . . <br />!!\{t.~:; Con~____ i 607.1 _ : Separate read,ily accessible manual ()r automatic thermostat for each systel'!!.____~----- <br />Insulation 604.1,602.1 Ceilings-Min. R-19. Common walls-Frame R-11 or CBS R-3 both sides. ! <br />! Common ceiling & floors R-11. ! <br /> <br />Ener!~yGauge TM DCA Form 600A-2004R <br /> <br />EnergyGauge@/FlaRES'2004 FLRCSB v4.5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.