My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-7064
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-7064
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:48:51 PM
Creation date
5/6/2008 2:26:38 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-7064
Building Department - Name
CITY OF ZEPHYRHILLS
Address
39421 SOUTH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
111
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Atlas 9100K Features, Options, Specifications <br /> <br />Flow rates <br />Standard, High, and Super-High flow <br />models that deliver from 15 to 40 GPM. <br /> <br />Master, Satellite or Combo <br />The Master/Satellite Combo saves <br />installation expense and extra equipment <br />costs while also saving forecourt space. <br />The front is master, and back is satellite <br />for adjacent master. <br /> <br />Meter <br />Four~piston, positive displacement flow- <br />through CFT meter bolsters resistance to <br />fuel contamination with self~cleaning <br />central chamber. <br /> <br />Solenoid valve <br />Standardized 1" solenoid valve that may be <br />cleaned or replaced without breaking <br />down pipe work. <br /> <br />Cabinet and finish <br />Top and sides are black or stainless steel, <br />with lower panels painted white or <br />optional specified color or stainless steel. <br /> <br />POS I Fleet Management Interface <br />Pulsers converts register revolutions to <br />electrical pulses for conn~ction to Gasboy <br />Fleet Management Systems or pas. Select <br />1:1, 10:1, or 100:1 ratios. <br /> <br />Electrical Keytrolâ„¢ pulser and <br />mounting kits <br />Includes necessary pulsers, top cabinet <br />panels, and wiring for factory~installed <br />Gasboy Electrical Keytrol. For gallons, <br />specify 10: 1 kits, and for liters, specify 1: 1 <br />kits. <br /> <br />Satellite compatible piping <br />Provides internal piping and union for <br />connecting to a satellite dispenser. <br />Available on remote dispenser models <br />only. <br /> <br />Lighted brand area and display <br />Illuminates product and register areas <br />for brighter day or night fueling. <br /> <br />Mechanical display register <br />Veeder-Root'" mechanical registers with <br />power reset interlock. Displays on both <br />sides include gallons or liters to 999.9 and <br />price per gallon or liter to 9.999. Includes <br />--'.,non-reseuable mechanical totalizer. <br /> <br />Pump and motor <br />Quiet, efficient rotary vane pump with an <br />air eliminator and self~priming built into <br />pump casting. Pumps include an improved <br />check valve design and field replaceable <br />shaft seal. Continuous duty motor. Refer <br />to table for horsepower. <br /> <br />Pressure regulator valve <br />Prevents product from leaking from the air <br />elimination vent in aboveground tank <br />installations. <br /> <br />Factory installed filter <br />Ten~micron filter helps ensure product <br />purity and helps protect critical <br />components from contamination. <br /> <br />External filter kits <br />Standard and high flow kits include <br />adapter, element, and pipe fittings. Specify <br />standard or hydrosorb element. <br /> <br />Ticket printers <br />Print ticket with volume dispensed. Zero <br />start and accumulative models. Not <br />available with light or EK options. <br /> <br />Hose <br />Optional 3/4" or 1" hardwall hose, variable <br />lengths available. <br /> <br />Automatic nozzles <br />Restrict flow when tank is full, 3/4" or 1". <br /> <br />Internal hose retractor <br />Helps keep hoses out of the fueling lane. <br /> <br />~. ......~"".,"~~;.- <br /> <br />". . .. !:Ht.c<.."",,, . <br />to~ '!RaT and run-over damage. <br /> <br />Hand crank <br />Ideal for regions where power outages are <br />likely. Allows dispensing by hand at a rate <br />of .6 liters per stroke. <br /> <br />Mechanical reset <br />Where a hand crank is likely to be used. <br /> <br />Vapor recovery <br />Complete vapor recovery kit or special <br />nozzle boot and hanger only. Field <br />installation required. <br /> <br />Voltage and frequency <br />Standard: 115VACl60 Hz. For other <br />applications &: international: <br />230VACl60Hz; 230VACl50Hz; <br />230VACl60Hz with 380VAC motor; <br />230VACl50Hz with 380VAC motor. <br /> <br />Inlet connection <br />Standard and High: 1-112" (3.8 cm) NPT. <br />Super High 2" (5cm) NPT. <br /> <br />Discharge <br />I" NPT, adjustable to 3/4" <br /> <br />Maximum working pressure <br />50 PSI <br /> <br />Dimensions <br />Units: 53~3/4"H x 28-112" W x 18-112"0. <br />Packaging: 67"H x 38"W x 25"0 <br /> <br />Approvals* <br />UL and cUL; US Weights and Measures for <br />the resale of fuel for applications involving <br />the contracted periodic billing of the fuel <br />dispensed (cardlocks); MC Certificate of <br />Approval for Canada Weights and <br />Measures; and NYCFD. <br /> <br />*Pending or in process as of <br />January 10, 2005. <br /> <br />Notices <br /> <br />Performance flow rates <br />Flow rates shown are maximum test rates. <br />Actual delivery rates will vary depending <br />upon the installation conditions, product <br />dispensed, added accessories and size of <br />submersible pump. Tested and calibrated <br />for accuracy at any speed or pressure. <br /> <br />Safety Warning <br />Failure to follow proper installation <br />instructions may result in property damage, <br />personal injury, or loss of life. Gasboy <br />products must be installed by a qualified <br />installer and used in conformance with all <br />building, fire, and environmental codes and <br />other safety requirements applicable to their <br />installation and use, including, but not <br />limited to, NFPA 30, NFPA 30A, and NFPA <br />70. This product is only part of a fuel <br />dispensing system. Additional accessories <br />or safety devices may be necessary to <br />meet the applicable codes. Gasboy <br />dispensers shall not be used for the direct <br />fueling of aircraft without filters, separators, <br />and other equipment necessary to ensure <br />product purity. <br />
The URL can be used to link to this page
Your browser does not support the video tag.